![Vanguard VMH2800TNC Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/vanguard/vmh2800tnc/vmh2800tnc_owners-operation-and-installation-manual_3571131016.webp)
16
103506
GAS RESIDENTIAL HEATERS
®
CORRECT FLAME PATTERN
AT HIGH POSITION
INCORRECT FLAME PATTERN
AT HIGH POSITION
Yellow
Tipping
Top of
Flame
About One
Inch Above
Logs
If burner flame pattern is incorrect, as shown in Figure 28
• turn heater off (see To Turn Off Gas to Appliance, page 15).
• see Troubleshooting, pages 17 through 19.
INSPECTING
BURNER
Continued
CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized
air, or small, soft bristled brush to
clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized
air to clean.
Exterior
• Use a soft cloth dampened with a
mild soap and water mixture. Wipe
the cabinet to remove dust.
Figure 28 - Incorrect Burner Flame Pattern
Figure 27 - Correct Burner Flame Pattern
SPECIFICATIONS
Btu (Variable)
14,000/28,000
Type Gas
Natural Only
Ignition
Piezo
Pressure Regulator Setting
3" W.C.
Inlet Gas Pressure (in. of water) *
Maximum
10.5"
Minimum
5"
Dimensions, Inches (H x W x D)
Heater
23.75 x 25.9 x 8.5
Carton
25.8 x 28.7 x 10.1
Weight (pounds)
Heater
29
Shipping
35
* For purposes of input adjustment