Vanguard VMH26TPA Скачать руководство пользователя страница 22

22

104059

COMPACT CLASSIC HEARTH FIREPLACE

VMH26TPA

®

TROUBLESHOOTING

Continued

 WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

 Operating fireplace where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Fireplace burning vapors from paint, hair

spray, glues, etc. (See 

IMPORTANT

statement above)

2. Low fuel supply
3. Gas leak. 

See Warning statement at

top of page

1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged

1. Gas leak.

 See Warning statement at

top of page

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak. 

See Warning statement at

top of page

1. Not enough combustion/ventilation air

OBSERVED PROBLEM

Fireplace produces a clicking/ticking noise
just after burner is lit or shut off

Fireplace produces unwanted odors

Fireplace shuts off in use (ODS operates)

Gas odor even when control knob is in OFF
position

Gas odor during combustion

Moisture/condensation noticed on windows

REMEDY

1. This is common with most fireplaces. If

noise is excessive, contact qualified ser-
vice person

1. Ventilate room. Stop using odor caus-

ing products while fireplace is running

2. Refill supply tank
3. Locate and correct all leaks (see Check-

ing Gas Connections, page 16)

1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and

Maintenance, page 23)

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 16)

2. Replace control valve

1. Take apart gas tubing and remove for-

eign matter

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 16)

1. Refer to Air for Combustion and Venti-

lation requirements (page 5)

www.desatech.com

Содержание VMH26TPA

Страница 1: ...stallation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or property damage Re fer to this manual for correct installation and operational pro cedures For assistance or addi tional information consult a qualified installer service agency or the gas supplier WARN...

Страница 2: ...es to cool before touching 18 Carefullysuperviseyoungchildrenwhen they are in same room with fireplace 19 Do not use fireplace if any part has been under water Immediately call a quali fied service technician to inspect the room fireplace and to replace any part of the control system and any gas con trol which has been under water 20 Turn off and unplug fireplace and let cool before servicing Only...

Страница 3: ...e packet 4 Check fireplace for any shipping damage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen DepletionSensorShutoffSystem ODS The ODS pilot is a required feature for vent free room fireplaces The ODS pilot shuts off the fireplace if there is not enough fresh air PIEZO IGNITION SYSTEM This firepl...

Страница 4: ...wer now Follow installation in structions provided with blower 5 Gently place back log on burner sup port see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten 6 Place branch on branch support see Figure 2 Do not allow branch to con tact flame If flame contacts branch soot will be created 7 Reattach scre...

Страница 5: ...r pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames be tween sole plates and floors be tween wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings If your home meets all of t...

Страница 6: ...ect vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can support _____________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 56 000 Btu Hr actual amount of Btu Hr used The space in t...

Страница 7: ...o Crawl Space To Attic AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 4 You can...

Страница 8: ... inches from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas CAUTION This fireplace cre ateswarmaircurrents Thesecur rents move heat to wall surfaces next to fireplace Installing fire place next to vinyl or cloth wall coverings or operating fireplace where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene...

Страница 9: ...ont facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover any neces sary openings like louvered slots WARNING Do not allow non combustible materials to cover any necessary openings like lou vered slots WARNING Use only noncom bustible mortar or adhesives when overlapping the front fac ing with noncombustible facing material WARNING Nev...

Страница 10: ...o wooden base Hole for 3 wood screw for attaching fireplace to mantel 11 Install gas line See Connecting To Gas Supply page 14 12 Check for leaks See Checking Gas Connections page 16 13 Place mantel around fireplace Be care ful not to damage wall or mantel 14 Place brass trim kit on the shoulder screws located on the side and top of the fireplace Firmly snap the brass trim over the shoulder screws...

Страница 11: ... Assembly Upper Louver Assembly Brass Screws Blower Bracket Mounting Holes 1 2 Remove Screw Valve Cover Shield Shoulder Screw Removing Valve Cover Shield 1 Open bottom louver assembly by swinging the assembly down see Fig ure 16 2 Using short Phillips screwdriver re move the screw under the center of the branch support Rotate valve cover shield clockwise and slide out IMPORTANT Do not remove shoul...

Страница 12: ...e rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 17 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch posi tion 1 Reconnect green and white wires Figure18 InstallingSwitchPlatetoValve Cover Shield Switch Plate Screw Valve Cover Shield INSTALLATION Continued 9 Install the switch plate on the valve cover shield with 2 10 screws...

Страница 13: ...16 AWG cord for lengths less than 50 feet Follow instructions Removing Valve Cover Shield page 11 then 1 Install a snap bushing found in hard ware kit into one of the holes found on rear of valve cover shield The other hole is for a strain relief clamp not supplied to secure incoming electrical supply 2 Follow steps 2 through 6 in Installing Blower Assembly pages 11 and 12 Also remove black wire f...

Страница 14: ...ing into fireplace controls If sediment trap is not installed or is installed wrong fireplace may not run properly Propane LP Supply Tank External Regulator Attaching Wood Base to Solid Floor For attaching base to solid floors concrete or masonry Note Floor anchors and mounting screws areinhardwarepackage Thehardwarepack age is provided with fireplace 1 Drill holes at marked locations using 5 16 d...

Страница 15: ...omthefireplace seeFigure24 The flexible gas supply line con nection to the manual shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line see Figure 25 Con nect flexible gas line to flexible gas line attached to gas regulator of fireplace see Figure 25 5 Check all gas connections for leaks See Checking Gas Connections pag...

Страница 16: ...ks at once WARNING Neveruseanopen flame to check for a leak Apply a mixture of liquid soap and water toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external regulator has been installed be tweenpropane LPsupplyandfire place See guidelines under Con necting to Gas Supply page 14 TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig ure 26 2 ...

Страница 17: ...light pilot with match see Manual Lighting Procedure page 18 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 This fireplace has a safety interlock system Wait one 1 minute before lighting pilot again 8 Turn control knob counterclockwise C clockwise to desired heating level The main burner shoul...

Страница 18: ...pliance if service is to be performed Shutting Off Burner Only pilot stays lit Turn control knob clockwise Clockwise to the PILOT position THERMOSTAT CONTROL OPERATION 1 Follow steps 1 through 5 under Light ing Instructions page 17 2 With control knob pressed in strike match Hold match to pilot until pi lot lights 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds ...

Страница 19: ...Pattern WARNING If yellow tipping occurs your fireplace could pro duce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow in structions at bottom of this page Yellow Tipping Top of Flame About One Inch Above Logs INSPECTING BURNER Thermocouple Pilot Burner Figure 31 Correct Pilot Flame Pattern Actual Pilot May Vary From Illustration Thermocouple Pilot Burner Fi...

Страница 20: ...e damaged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace ignitor 6 Replace ignitor 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control kno...

Страница 21: ...eplace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products OBSERVED PROBLEM Burner does not light after ODS pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit Whitepowderresidueformingwi...

Страница 22: ...tement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM Fireplace produces a clicking ticking noise just after burner is lit or shut off Fireplace produces unwanted odors Fireplace shuts off in use ODS operates Gas odor even when control knob is in OFF p...

Страница 23: ...tore or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t follow direc tionsonthecan youcoulddamagethepilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on inj...

Страница 24: ... HEARTH FIREPLACE VMH26TPA ILLUSTRATED PARTS BREAKDOWN VMH26TPA 12 1 12 2 23 29 43 32 36 38 13 7 8 33 43 11 10 27 4 7 30 1 3 2 9 17 19 6 22 31 21 41 26 42 39 40 16 15 18 24 28 5 34 25 20 35 1 4 35 2 12 24 12 1 14 25 14 43 3 37 ...

Страница 25: ...98303 02 Regulator Screw 2 19 104335 01CK Outer Shell Base 1 20 102649 01CJ Branch Support 1 21 099415 09 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilot Tube 1 25 098271 06 Ignitor Cable 1 26 103845 10 Injector 1 27 102458 01CK Front Top Middle 1 28 098249 01 Nut M5 6 29 098522 15 Gas Valve 1 30 102639 01 Baffle 1 31 101628 01 Flexible Conn...

Страница 26: ...is product If they can t supply original replacement part s call DESA International s Technical Service Department at 1 800 323 5190 for referral information When calling DESA International have ready your name your address modelandserialnumbersofyourfireplace how fireplace was malfunctioning type of gas used propane LP or natural gas purchase date Usually we will ask you to return the defec tive ...

Страница 27: ... or paint Complete assembly instructions in cluded Three sided brass trim kit included CABINET MANTEL WITH BUILT IN HEARTH BASE AND TRADITIONAL SQUARE LEG STYLING Unfinished GM923U Finished GM922F For use with fireplace A hardwood mantel and hearth base offers compact styling and completes the fireplace look Available in a stained or an unfinished ready to stain or paint Oak Veneer over hardwood C...

Страница 28: ...ects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTI...

Отзывы: