6

104325

COMPACT CLASSIC HEARTH FIREPLACE

VMH26NR

®

AIR FOR
COMBUSTION AND
VENTILATION

Continued

 WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space

or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of
the methods described in the 

National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3 or applicable local codes.

DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space:

 Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills

between the rooms.

1.

Determine the volume of the space (length x width x height).

Length x Width x Height = _______________ cu. ft. (volume of space)

Example:

 Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of
the space.

2.

Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example:

 2560 cu. ft. (volume of space) ÷ 50 cu. ft = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.

Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace

____________ Btu/Hr

Gas water heater*

____________ Btu/Hr

Gas furnace

____________ Btu/Hr

Vented gas heater

____________ Btu/Hr

Gas fireplace logs

____________ Btu/Hr

Other gas appliances*

____________ Btu/Hr

Total

____________ Btu/Hr

* Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.

Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)
_________________ Btu/Hr (actual amount of Btu/Hr used)

Example:

51,200 Btu/Hr (maximum the space can support)
56,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin-

ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.

B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.

Example:

Gas water heater

30,000

Btu/Hr

Vent-free fireplace +

26,000

Btu/Hr

Total

=

56,000

Btu/Hr

Содержание VMH26NR

Страница 1: ...t Installation and service must be per formed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury...

Страница 2: ...ll into the control area of fireplace 7 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 8 This fireplace is designed...

Страница 3: ...ping dam age If fireplace is damaged promptly inform dealer where you bought fire place SAFETY PILOT This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The ODS pilot is a re...

Страница 4: ...gure 2 3 Lift screen up and pull out to remove 4 An optional blower is available See Ac cessories pages 26 and 27 Install op tional blower now Follow installation instructions provided with blower 5 G...

Страница 5: ...in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere...

Страница 6: ...can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ____________ Btu Hr Gas water heater ____________ Btu Hr Gas furnace ____________ Btu Hr Vented gas heater...

Страница 7: ...Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Figure 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfre...

Страница 8: ...s to create the easiest installation see Built In Fireplace Installation page 9 CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install fireplace Call dealerwhereyoubo...

Страница 9: ...verlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover any neces sary openings like louvered slots WARNING Do not...

Страница 10: ...ews provided and attach fireplace base to wooden base see Figure 12 8 Remove brass trim kit and mantel Be careful not to damage wall or mantel 9 Place wood base next to wall at instal lation location...

Страница 11: ...of valve cover shield 2 Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly 3 Note the wire locations on back of AUTO OFF ON switch The terminals on back of...

Страница 12: ...G Alicensedelectri cianmustconnectthewiringhar ness to electrical supply follow ing all local codes Electrician must provide a clamp on the box cover to secure the wiring Wir ing should be routed thro...

Страница 13: ...tubingmaybeusedincer tainareas Checkyourlocalcodes Use pipe of 1 2 or greater diam eterto allow proper gasvolumeto fireplace If pipe is too small un due loss of pressure will occur CAUTION Usepipejoin...

Страница 14: ...t concealed gas con nections A flexible gas line is provided to allow accessibility fromthefireplace seeFigure24 The flexible gas supply line con nection to the manual shutoff valve should be accessib...

Страница 15: ...ual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressur...

Страница 16: ...should be done by a quali fied installer familiar with low voltage wiring procedures INSTALLATION Continued OPTIONAL WIRELESS HAND HELD REMOTE CONTROL ACCESSORIES GHRC Series GHRCT Series Installing...

Страница 17: ...minal of 25 ft wire to bottom contact of switch see Figure31 2 Connect remaining wire terminal to the TH terminal on the control valve Make sure that wire terminals are in the positions on your unit a...

Страница 18: ...n 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety in formation column 1 If you don t smell gas go to the next step 6...

Страница 19: ...amount of space to be heated the output of the central heating system etc For wall thermostat operation follow in struction supplied with thermostat acces sory GWMT1 For wall switch operation followi...

Страница 20: ...structions on page 17 of this manual IMPORTANT The hand held remote control unit must be near the heater Do not keep the hand held remote control unit too close to the heater The thermostat on the han...

Страница 21: ...e Pattern Figure42 IncorrectBurnerFlamePattern WARNING If yellow tipping occurs your fireplace could pro duce increased levels of carbon monoxide If burner flame pat tern shows yellow tipping follow i...

Страница 22: ...maged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind...

Страница 23: ...1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum installation clear...

Страница 24: ...oise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Thi...

Страница 25: ...the unit every 2 500 hours of operation or every three months Wealsorecommendthatyoukeeptheburner tube and pilot assembly clean and free of dustanddirt Tocleanthesepartswerecom mend using compressed...

Страница 26: ...stain or paint Complete assembly instructions in cluded Three sided brass trim kit included CABINET MANTEL WITH BUILT IN HEARTH BASE AND TRADITIONAL SQUARE LEG STYLING Unfinished GM923U Finished GM922...

Страница 27: ...nder warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Technical Service Department at 1 800 323 5190...

Страница 28: ...ASSIC HEARTH FIREPLACE VMH26NR 39 37 38 4 22 40 11 28 30 12 7 35 25 10 9 7 23 1 2 43 43 8 14 6 24 33 19 34 31 32 13 41 21 5 26 18 15 27 1 27 2 43 3 43 29 16 18 3 17 42 36 4 4 20 43 ILLUSTRATED PARTS B...

Страница 29: ...19 103845 11 Injector 1 20 102458 01CK Middle Rail 1 21 098249 01 Nut M5 6 22 103781 01 Gas Valve 1 23 102639 01 Baffle 1 24 101628 01 Flexible Connector 1 25 104305 01 Control Shield 1 26 103295 01CJ...

Страница 30: ...aused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO THE FU...

Отзывы: