9

 CAUTION: This fireplace in-

sert creates warm air currents. 

These currents move heat to wall 

surfaces next to fireplace insert. 

Installing fireplace insert next to 

vinyl or cloth wall coverings or 

operating fireplace insert where 

impurities (such as, but not lim-

ited to, tobacco smoke, aromatic 

candles,  cleaning  fluids,  oil  or 

kerosene  lamps,  etc.)  in  the 

air exist, may discolor walls or 

cause odors.

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo-

sote, ashes and loose paint by a 

qualified chimney cleaner.

Note:

 Your Vanguard fireplace insert is designed 

to be used in zero clearance installations. Wall or 

framing material can be placed directly against any 

exterior surface on the rear, sides or top of your 

fireplace insert, except where standoff spacers are 

integrally attached. If standoff spacers are attached 

to your insert, these spacers can be placed directly 

against wall or framing materials.

IMPORTANT:

 

Vent-free heaters add moisture to 

the air. Although this is beneficial, installing fire-

place in rooms without enough ventilation air may 

cause mildew to form from too much moisture. See 

Air for Combustion and Ventilation, 

page 6. 

IMPORTANT:

 

Make sure the fireplace insert is 

level. If fireplace insert is not level, log set will 

not work properly. 

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for 

your unit. If your gas supply is not correct, do not 

install fireplace insert. Call dealer where you bought 

fireplace insert for proper type fireplace insert.

  WARNING:  This  appliance 

is equipped for (natural or pro-

pane/LP) gas. Field conversion 

is not permitted.

INSTALLATION

Continued

ELECTRICAL HOOKUP

(Blower Accessory)

This fireplace insert includes a blower assembly 

with an electrical cord. The electrical cord is five 

feet in length. You must locate fireplace insert 

within reach of a 120 volt grounded electrical 

outlet. If not, install and properly ground GA3555, 

three-prong 120 volt electrical outlet, in fireplace 

insert. Follow instructions included in kit (see 

Accessories, 

page 34).

INSTALLING SURROUND KIT (GS38 
OR GS43)

  CAUTION:  Close  masonry 

fireplace  damper  securely  be-

fore installing fireplace insert. If 

chimney does not have a damper, 

block  or  cap  top  of  chimney. 

Failure to cap an open chimney 

could cause drafts that can affect 

the  heater’s  performance  and 

increase surface temperatures.

 CAUTION: A GS38 or GS43 

surround kit accessory must be 

installed on this fireplace insert 

before  installing  into  your  ma-

sonry fireplace or wall opening.

Note:

 

Use  the  accessory  which  best  covers 

the existing masonry fireplace opening or wall 

opening.
•  Model GS38 Surround Kit (for use with fire-

places with an opening smaller than 30" H and 

38" W)

•  Model GS43 Surround Kit (for use with fire-

places with an opening 30" to 36 

3

/

4

" H and 38  

to 43" W)

1.  Using a 5/16" nut driver, remove two shipping 

screws and screen (see Figure 5, page 10). 

Discard these screws. Remove 5/16" screen 

mounting shoulder screws (do not discard).

2.  Remove log packaging from firebox cavity.
3.  Align holes in left surround side panel with 

screen mounting screw holes. Replace 5/16" 

screen mounting shoulder screws removed in 

step 1 (see Figure 6, page 10). Do not tighten. 

Install Phillips screw in bottom (see Figure 6, 

page 10). Repeat for right side.

Содержание Vi33NRB

Страница 1: ...LL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instruct...

Страница 2: ...liance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be made by a licensed pl...

Страница 3: ...It is your guide to safe and proper operation of this replace WARNING Any change to this heater or its controls can be dangerous WARNING Do not allow fans to blow directly into the replace insert Avo...

Страница 4: ...e insert needs fresh air ventila tion to run properly This replace insert has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the replace insert if not enough fresh air is ava...

Страница 5: ...e packing Note The hood is located in the packing on the right hand side of the heater front Lift the heater off the bottom tray 2 Locate two screws above top corners of the replace insert screen Remo...

Страница 6: ...ke your home energy ef cient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper combustion and ventilation Exhaust fans replaces clothes dr...

Страница 7: ...l burning appliances in the space Vent free replace ___________ Btu Hr Gas water heater ___________ Btu Hr Gas furnace ___________ Btu Hr Vented gas heater ___________ Btu Hr Gas replace logs ________...

Страница 8: ...door into adjoining room see option 3 Figure 3 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Fig...

Страница 9: ...ace insert WARNING This appliance is equipped for natural or pro pane LP gas Field conversion is not permitted INSTALLATION Continued ELECTRICAL HOOKUP Blower Accessory This replace insert includes a...

Страница 10: ...ly Make sure each part fits properly Firmly tighten all screws installed during assembly INSTALLATION Continued Figure 5 Removing Screws and Screen Shipping Screw DISCARD Screen Mounting Shoulder Scre...

Страница 11: ...Phillips screws provided to attach hood to replace insert and 2 Phillips screws provided to attach hood and surround sides to replace insert Figure 10 Installing Hood to Firebox Screws INSTALLATION CL...

Страница 12: ...ever connect natural gas replace insert to private non utility gas wells This gas is commonly known as wellhead gas Installation Items Needed Before installing replace insert make sure you have the it...

Страница 13: ...Figure 13 External Regulator with Vent Pointing Down Propane LP Supply Tank External Regulator Vent Pointing Down Locate sediment trap where trapped matter is not likely to freeze A sediment trap tra...

Страница 14: ...tor Provided with Fireplace Insert To Fireplace Gas Regulator Equipment Shutoff Valve Propane LP To External Regulator Natural To Gas Meter CHECKING GAS CONNECTIONS WARNING Testallgaspiping and connec...

Страница 15: ...e Figure 19 Apply a noncorrosive leak detection uid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light replace insert see Operating Fireplace Insert page 19 Check all other...

Страница 16: ...LATION Continued ASSEMBLING AND ATTACHING TRIM 1 Remove three pieces of surround trim from packaging 2 Locate four 6 screws two adjusting plates with set screws and two shims in the hardware packet 3...

Страница 17: ...that no ame comes in contact with any log With the heater set to HI check toseeif amescontactanylog If so reposition logs according to the log installation instructions in this manual Flames contact...

Страница 18: ...STALLING 9 VOLT BATTERIES Two 9 volt batteries not included are required to operate this heater with the wireless hand held remote control set Install one battery in the receiver and one in the hand h...

Страница 19: ...system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING You must oper ate this heater with the replace insert screen in place Make sure replace insert screen is installed...

Страница 20: ...nob clockwise to the OFF position 2a Set selector switch in the OFF position 2b If Using Optional Hand Held Remote Set remote selector switch in the OFF position to keep from draining battery Shutting...

Страница 21: ...nt object Manual Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote control 2 Press the MANU button to turn on the replace 3 Press the POWER and LOCK buttons together to...

Страница 22: ...rate In the AUTO position the blower will start when the thermostat senses a suf cient increase in rebox temperature Note Your gas logs and thermostat blower will not turn on and off at the same time...

Страница 23: ...cool before cleaning CAUTION You must keep control areas burner and circu latingairpassagewaysofheater clean Inspect these areas of heater before each use Have heater inspected yearly by a quali ed s...

Страница 24: ...le LOGS If you remove logs for cleaning refer to Install ing Logs page 17 to properly replace logs Replace log s if broken or chipped dime sized or larger BURNER PRIMARY AIR HOLES Air is drawn into th...

Страница 25: ...en installed 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing...

Страница 26: ...2 AfterODS pilotlights keepcon trol knob pressed in 30 seconds 3 Fully open equipment shutoff valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance p...

Страница 27: ...on requirements page 6 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural or propane LP gas company...

Страница 28: ...urner 2 Gas leak See Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting ame pattern 3 Air holes at burner inlet blocked 4 Burner ame holes blocked REMEDY 1 Open...

Страница 29: ...urchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA He...

Страница 30: ...01B 30 ILLUSTRATED PARTS BREAKDOWN MODELS VI33NRB AND VI33PRB 17 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 5 9 28 14 13 25 15 16 21 11 10 19 20 19 23 24 22 18 1B 1A 1C 27 4 Note Items 27 and 28 a...

Страница 31: ...10 104236 01CK 104236 01CK Painted Base Assy 1 11 M12461 26 M12461 26 Screw 10 x 32 4 12 Firebox Bottom 1 13 103284 03 103284 03 Wiring Harness 1 14 098265 02 098265 02 Elbow Male 1 15 103782 01 10378...

Страница 32: ...w desatech com 113195 01B 32 ILLUSTRATED PARTS BREAKDOWN FIREPLACE INSERT MODELS VI33NRB AND VI33PRB 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 15 23 4 6 6 17 16 18 19 20 21 22 22 23 14 24 25 14 2...

Страница 33: ...05518 01CK Firebox Hood 1 8 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 Firebox Top 1 11 Outer Base 1 12 Firebox Wrapper 1 13 101614 02 Cover and Switch Assembly 1 14 M11084 26 Hex Screw 10 46 1...

Страница 34: ...STAT REMOTE CONTROL KIT GHRCTB SERIES For all models Allows the gas log heater to be operated in a manually or thermostatically con trolled mode You can turn the gas log heater on and off without ever...

Страница 35: ...____ _____________________________________________________ _____________________________________________________ _____________________________________________________ _________________________________...

Страница 36: ...r defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner T...

Отзывы: