11
103661
Figure 7 - Minimum Clearance to Wall and Ceiling
52"
20"
20"
Door
Handle
INSTALLING
Continued
INSTALLING GA3700 BLOWER ACCESSORY
1. Install blower assembly per instruction sheet included in blower accessory kit.
2. Route blower power cord out the back of the stove and to a grounded, three-
prong 120-volt electrical outlet. Plug electrical cord into outlet.
2. Attach gas log heater base to stove bottom with two screws included with base
(see Installing Heater Base Assembly in log set owner’s manual).
NOTICE
Most building codes do not permit concealed gas connections. A
flexible gas line is provided to allow accessibility from the stove.
The manual shutoff valve should be accessible.
INSTALLING LOG HEATER IN STOVE
WARNING ICON
G 001
CAUTION
Do not pick up log base assembly by burners. This could damage
burners. Only handle base by grates.
1. If installing GA3700 Blower Accessory , see Installing GA3700 Blower Acces-
sory, above.
B. Clearances from the side of the stove opening to any combustible wall should not be
less than 20 inches (see Figure 7).
C. Clearances from the top of the stove opening to the ceiling should not be less
than 52 inches (seeFigure 7).