Vanguard SDVBN Скачать руководство пользователя страница 23

23

105499

OWNER’S MANUAL

Each log is marked with a number. These
numbers will help you identify the log when
installing. It is very important to install
these logs exactly as instructed. Do not
modify logs. Only use logs supplied with
freestanding burner system. Do not use if
any log(s) are broken (see Replacement
Parts
, page 31).

1.

Remove glass door. See Removing/Re-
placing Glass Door, 
page 22.

2.

Place log #1 (back log) on top of grate.
Make sure the notches in the bottom of
the log fit over the grate (see Figure 53).

2.

Rest log #2 (large front log) on the pins on
the front part of the grate (see Figure 54).

3.

Place log #3 (crossover log) onto the
rear and front logs. Make sure it is seated
properly into the notch on the front log
and over the raised triangular portion of
the rear log as shown in Figure 55.

 WARNING: Failure to position

the parts in accordance with these
diagrams or failure to use only parts
specifically approved with this
burner system may result in prop-
erty damage or personal injury.

INSTALLING LOGS, LAVA
ROCK AND GLOWING
EMBERS

STOVE AND
DIRECT-VENT
BURNER SYSTEM
INSTALLATION

Continued

1

2

3

4

Figure  53 - Installing Log No. 1

Figure 54 - Installing Log No. 2

Figure 55 - Installing Log No. 3

Figure 56 - Installing Log No. 4

 WARNING: The glass door

must be securely in place before
running this burner system. Do
not run this burner system if glass
is missing or broken.

NOTICE: Do not put lava rock on
burner or under burner. Placing
lava rock on burner could cause
performance problems.

4.

Place  log #4 (small log) onto the front
left part of the grate making sure the
notches fits over the prong of the grate.
See Figure 56.

Figure 57 - Placing Ember Material on
Burner

5.

Lava rock may be placed along sides
and front inside burner system bottom.
This may not be visible when you have
replaced the front of the stove. It is not
necessary to use all of the lava rock
provided.

6.

Pull ember material apart into pieces
no larger than a dime. Place these
pieces loosely and sparingly directly
onto the exposed section of the front
burner and along the space between the
burner and grate prongs (see Figure 57).
This will create the glowing ember ap-
pearance as the flame touches the em-
ber material. Do not block air slots by
using too much ember material in one
area. It is not necessary to use all of the
ember material provided.

7.

Replace the glass door and stove
front. See Removing/Replacing Glass
Door
, page 22.

8.

Place lava rock plate in space between
the front of the cast iron stove and the
glass front of the insert. Place lava rock
on the plate for a decorative appear-
ance. It is not necessary to use all of
the lava rock provided.

Содержание SDVBN

Страница 1: ...consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not followedexactly afireorexplosionmayresultcaus ing property damage personal injury or...

Страница 2: ...installedbyaquali fied service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed...

Страница 3: ...er system has a piezo ignitor This system requires no matches batteries or other sources to light burner system Figure1 VanguardDirect VentBurnerSystemShownInstalledinApprovedVanguard Cast Iron Stove...

Страница 4: ...see Figure 3 and Figure 4 on page 5 4 This stove is a freestanding unit de signed to set directly on the floor If your stove is to be installed directly on carpeting vinyl tile or any combustible mate...

Страница 5: ...t Wood From The Bottom of The Stove Figure 9 Locating Threaded Holes for StoveBottom Legs andDoorAttachment Figure 6 Removing Back Panel Bolt Product Identification Label Back Stove Panel Pallet Wood...

Страница 6: ...law Make final adjustment and door leveling after stove is in nor mal standing position 13 Carefully lift stove back up on its four attached legs 14 Set top grate into stove top INSTALLING DIRECT VENT...

Страница 7: ...n ob NOTICE If installing blower in an existingstoveburnersystemwith gas connections shut off gas supply and disconnect stove burner system from gas supply Contact a qualified service per son to do th...

Страница 8: ...l over vent pipe connec tion on burner system Rear cover will rest on the bottom ledge of the stove body 2 Usingscrewsprovided attachrearcover to back of stove body See Figure 17 IMPORTANT This rear c...

Страница 9: ...paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inches 610mm abov...

Страница 10: ...Termination Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Terminat...

Страница 11: ...Rigid vent pipes and fittings have spe cial twist lock connections Assemble the desired combination of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twi...

Страница 12: ...up Insure proper clearance of 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 23 Note Re place the wood screws with appropri ate fasteners for stucco br...

Страница 13: ...e 14 show different configurations for venting with horizontal termination Each figure includes a chart with vertical mini mum maximum and horizontal maximum dimensions which must be met Seal all conn...

Страница 14: ...30 to avoid cutting loadbearing members Note Pay spe cial attention to these installation in structions for required clearances air space to combustibles when passing through ceilings walls roofs encl...

Страница 15: ...outer pipe connection with high temperature sili cone sealant as specified in the second warning statement on page 10 Note If the vent pipe passes through any occupiedareasabovethefirstfloor includin...

Страница 16: ...ith high temperature sili conesealantasspecifiedinthesecondwarn ing statement on page 10 Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 m...

Страница 17: ...Support RoofFlashing RTVSilicone Ver tical Termination and 26 screws D1000BK 7 x 12 Black Coaxial Pipe 1 pk D1010BK 7 x 24 Black Coaxial Pipe 1 pk D1020BK 7 x 48 Black Coaxial Pipe 1 pk D1030BK 7 Adj...

Страница 18: ...s line with gas con nector if allowed by local codes not provided AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the A G A...

Страница 19: ...ed fittings for leaks CHECKING GAS CONNECTIONS WARNING Test all gas pip ing and connections for leaks after installing or servicing Cor rect all leaks at once WARNING Neveruseanopen flame to check for...

Страница 20: ...off valve see Figure 41 2 Open propane LPsupply tank valve for propane LPburner system or main gas valve located on or near gas meter for natural gas burner system 3 Make sure control knob of burner s...

Страница 21: ...erminal W and R Figure 44 Control Valve Terminals W R Terminal W Terminal R Continued To Control Switch or Optional Accessory 5 Gently remove the cover of the ther mostat from the base Grasp the sides...

Страница 22: ...ery clip andconnecttoterminals seeFigure48 5 Place receiver into valve bracket and align holes see Figure 49 6 Use push in fasteners included with receiver to secure to bracket 7 Connect the wires fro...

Страница 23: ...No 4 WARNING The glass door must be securely in place before running this burner system Do notrunthisburnersystemifglass is missing or broken NOTICE Do not put lava rock on burner or under burner Plac...

Страница 24: ...n the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosi...

Страница 25: ...or OFF buttons on the hand held remote control unit Inautomode theroomtemperature iscontrolledbythethermostatinthe hand held remote control unit To increase the room temperature press the top arrow o...

Страница 26: ...rols are located on the left side of the switch bracket to the left just inside the door Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON setting and an OFF...

Страница 27: ...edbythemanufacturershould be used when replacing broken ordamagedglassdoorpanel see ReplacementParts page31 This glass door panel is a complete unit No substitute materials may be used If glass has be...

Страница 28: ...gged pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep...

Страница 29: ...emoved from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 27 or replace burner orifice 1 Adjust the log set so that the flame...

Страница 30: ...ontrol valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system produces unwanted...

Страница 31: ...Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarrantycoveragefor parts replaced under wa...

Страница 32: ...1 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Stove and Burner System 27 x 26 1 4 x 26 1 8 27 x 26 1 4 x 26 1 8 685 8 x 666 7 x 663 4mm 685 8 x 666 7 x 663 4mm Carton Insert Only 23 1 4 x...

Страница 33: ...tems THERMOSTATICALLY CONTROLLED BLOWER KIT DA3610T Provides better heat distribution Blower turns off and on automatically as needed Completeinstallationandoperationinstruc tions included in this man...

Страница 34: ...D BURNER SYSTEM 105499 SDVBN A AND SDVBP A ILLUSTRATED PARTS BREAKDOWN SDVBN A SDVBP A LO H I P I L O T OFF ON 24 27 19 20 21 23 26 1 26 4 26 2 26 3 29 30 4 25 1 2 4 4 7 8 9 10 11 13 12 31 15 16 17 18...

Страница 35: ...l 1 105523 02 Burner Propane LP 1 20 104506 01 Orifice Natural 1 104506 18 Orifice Propane LP 1 21 104507 01 Brass Elbow 1 22 104508 01 Brass Fitting 2 23 105493 01 Aluminum Tubing Assy 1 24 104510 01...

Страница 36: ...IRON STOVE AND BURNER SYSTEM 105499 SDVBN A AND SDVBP A ILLUSTRATED PARTS BREAKDOWN AMITY SCIVF SERIES PSCIVF SERIES Indicates Color Suffix Designation 1 2 5 8 7 4 6 5 5 7 1 7 2 5 4 7 3 3 AMITY STOVE...

Страница 37: ...eg Metallic Charcoal 4 Total Per Stove 1 104175 07 One Leg Porcelain Enamel Red 4 Total Per Stove 1 104175 08 One Leg Porcelain Enamel Teal Green 4 Total Per Stove 1 104175 09 One Leg Porcelain Enamel...

Страница 38: ...ostsrelatedtorepairingadefectivestoveandburnersystemwillbetheresponsibilityoftheowner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY A...

Отзывы: