Vanguard MBDV37 Скачать руководство пользователя страница 35

35

106497

OWNER’S MANUAL

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply might be low

(propane/LP units only)

When Gas Quality Is Bad

• pilot will not stay lit

• burners will produce flames and soot

• fireplace will backfire when lit

If you feel your gas pressure is too low or gas
quality is bad, contact your local natural or
propane/LP gas supplier.

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-DESA LOG
(1-800-337-2564).

You can also visit DESA International’s
technical service web site at

www.desatech.com

.

REPLACEMENT
PARTS

WIRING DIAGRAM

 CAUTION: Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Note: 

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can not supply original replacement
part(s), call DESA International’s Techni-
cal Service Department at 1-800-DESA
LOG (1-800-337-2564).

When calling DESA International, have ready

• your name

• your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can not supply original replacement
part(s), call DESA International’s Parts De-
partment at 1-800-972-7879 for referral in-
formation.

When calling DESA International, have ready

• model number of your fireplace

• the replacement part number

Thermocouple

Incoming
Main
Gas
Supply

Piezo Ignitor

Control
Valve

Variable
Speed
Control

Electrical Rating:
120v, 60Hz, 0.7A

Pilot

TH

TP

TH/TP

Thermopile

Piezo Ignitor

Do Not

Connect
To 120V

N.O.SW

(Wall Switch)

Remote

Control

Pilot 

Gas Line

Wireway

GND

BLK

WHT

GRN

Incoming

120V AC

(Fuse Box

or

Breaker)

Connectors
(Not Supplied)

Field Wire

N.O.SW

MBDV37

MBDV41

Dimension, Inches/mm (HxWxD)

Fireplace

33" x 37" x 18 

1

/

2

"

35" x 41" x 18 

1

/

2

"

838 x 940 x 470mm

838 x 1041 x 470mm

Carton

36" x 39" x 19 

1

/

2

"

36" x 43" x 19 

1

/

2

"

914 x 991 x 495mm

914 x 1092 x 495mm

Weight, lbs/kg

Fireplace

127 lbs/58 kg

137 lbs/62 kg

Shipping

130 lbs/59 kg

140 lbs/64 kg

SPECIFICATIONS

Содержание MBDV37

Страница 1: ...hbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or...

Страница 2: ...bjects 14 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fire place nameplate 15 This appliance when installed must be electrically groun...

Страница 3: ...ncy backup heat PIEZO IGNITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Direct Vent Fireplace Glass Door Assembly Blowe...

Страница 4: ...e to combustibles 37 1 2 41 1 2 34 3 4 36 3 4 20 Vertical Termination 19 Horizontal Termination Note Where two numbers are given the top number is exclusive to the 37 Fireplace and the bottom number i...

Страница 5: ...using the following guidelines Only use Vanguard or Simpson Dura Vent GS venting components or kits spe cifically approved for this fireplace Minimum clearance between vent pipes and combustible mater...

Страница 6: ...or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inches 610mm...

Страница 7: ...are two basic types of direct vent installation Horizontal Termination Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose It is also i...

Страница 8: ...all local building codes Note Wheninstallinginachase youshould insulate the chase as you would the outside walls of your home This is especially im portant in cold climates Minimum clear ance between...

Страница 9: ...wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 13 Note Re place the wood scr...

Страница 10: ...llation UP Horizontal Venting See information in Figure 17 for Vertical V and Horizontal H maximums and minimums The same amounts apply for flexible venting Note Figure 16 applies to rigid venting onl...

Страница 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Страница 12: ...obstruct the venting system consider an offset see Figure 21 to avoid cutting loadbearing members Note Pay spe cial attention to these installation in structions for required clearances air space to c...

Страница 13: ...using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold th...

Страница 14: ...ION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Venting Configuration...

Страница 15: ...izontal Termination RTV Silicone and 20 Screws CVK Corner Vent Kit Includes 7 x 30 Elbow 7 x 90 Elbow 7 AdjustableGalva nized Pipe 7 12 6 Pipe Wall Thimble Horizontal Termina tion RTVSiliconeand20Scre...

Страница 16: ...lace IMPORTANT Make sure fireplace is level before securing If fireplace is not level it will not work properly SIMPSON DURA VENT GS 4 x 6 5 8 Number Description Available from DESA International SD20...

Страница 17: ...und wire is tight 4 Remove screws securing the plate con taining the ON OFF switch to the bot tom of the firebox and set aside 5 Place speed control against back of this plate and push the plastic con...

Страница 18: ...STALLATION Continued Figure 36 Installing Remote Receiver Shown from Rear of Mounting Bracket Figure 37 Installing Battery in Receiver Battery Clip 9 Volt Battery Receiver Terminal Wires Receiver Moun...

Страница 19: ...the external regulator between the heater and propane LP supply CAUTION Usepipejointseal ant that is resistant to liquid pe troleum LP gas Figure 39 External Regulator with Vent Pointing Down Propane...

Страница 20: ...knockout hole on firebox bottom 3 Attach a 45 flare union gas connector to flexible gas line from gas supply see Figure 41 Connect flare union to flex ible gas line attached to gas regulator of firep...

Страница 21: ...pen propane LPsupply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in the OFF position 4 Check a...

Страница 22: ...ews from the three tabs at the top of the glass door while hold ing door securely keeping it from fall ing forward 3 Grasp door by both sides and ease it upward off of the lower bracket see Figure 47...

Страница 23: ...gure 48 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using the same meth...

Страница 24: ...plied with fireplace Removeglassdoor SeeRemoving Replacing GlassDoor page22 Installlogsaccordingto instructions for fireplace model numbers Fireplace Models MBDV37 and MBDV41 1 Place log 1 back log on...

Страница 25: ...re move the broken glass door Dis card safely A glass door kit can be ordered through your local distributor Do not substitute other material for the glass WARNING Children and adults should be alerte...

Страница 26: ...ing for lighting 7 Turn gas control knob counterclock wise to PILOT 8 Push in gas control knob all the way and hold Immediately light the pi lot by repeatedly depressing the piezo spark ignitor until...

Страница 27: ...ATING BLOWER Locate the blower controls by opening the lower louver panel on the fireplace Blower controls are located on the left side of the switch bracket to the left just inside the louver panel T...

Страница 28: ...Inspect joints to verify that no pipe sec tion or fitting has been disturbed and loosened Check mechanical supports such as wall straps for rigidity WARNING Turn off fireplace and let cool before cle...

Страница 29: ...S FOR CONVERSION NATURAL TO PROPANE LP BURNER AIR SHUTTER ADJUSTMENT MAIN BURNER ORIFICE AND PILOT ORIFICE CONVERSION 1 Remove the upper louver panel and glass door see Removing Replacing Glass Door p...

Страница 30: ...on nut Main Burner Orifice 18mm Hex Brass Elbow Apply Thread Sealant Here Only Figure 62 Removing Replacing Main Burner Orifice Thermopile Pilot Burner Thermocouple Piezo Ignitor 12mm Hex Pilot Orific...

Страница 31: ...n loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut ho...

Страница 32: ...defective REMEDY 1 Check to see if you have gas supply 2 Hold control valve in the PILOT position for2to3minutestopurgeair Ifyousmell gasstopandwaitforafewminutesbefore trying to light the fireplace...

Страница 33: ...P or natural gas company 2 Clean burner see Cleaning and Maintenance page 28 or replace burner orifice 1 Adjust the log set so that the flame does not excessively impinge on it 2 Inspect the opening a...

Страница 34: ...Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odo...

Страница 35: ...supply original replacement part s call DESA International s Techni cal Service Department at 1 800 DESA LOG 1 800 337 2564 WhencallingDESAInternational haveready your name your address modelandserial...

Страница 36: ...6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 42 34 2 34 4 34 1 34 5 35 36 35 37 38 5 5 5 50 51 39 45 46 35 47 48 49 44 6 41 40 43 6 5...

Страница 37: ...7 Natural 1 104506 03 Orifice 41 Natural 1 27 104507 01 Brass Elbow 1 28 104508 01 Brass Fitting 2 29 104509 01 Aluminum Tubing Assy 1 30 104510 01 Pilot Tubing Assy 1 31 101628 04 Flexible Connector...

Страница 38: ...magnetic backing which makes installation and removal quick and easy They are designed to go at the top and bottom of the glass door on BDV units Note Remove the plastic film covering on strips befor...

Страница 39: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 40: ...sts related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THISEXPRESS WARRANTYEXCLUDESANYANDALLO...

Отзывы: