Vanguard FLAME-MAX Скачать руководство пользователя страница 3

OWNER’S MANUAL

3

105187

PRODUCT
IDENTIFICATION

Figure 1 - Product Identification

Control Knob

Base Assembly

Piezo Ignitor

Burner

One Piece Log Set

Flame-Max

®

Vintage Oak Logs

Flame-Max

®

Golden Oak Logs

Flame-Max

®

Birch Logs

Control Knob

Piezo Ignitor

One Piece
Log Set

One Piece
Log Set

Control Knob

Piezo Ignitor

Base Assembly

Base Assembly

PRODUCT
FEATURES

OPERATION

This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
realistic, dancing yellow flames. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANS Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free
heaters. Non-thermostat models may also
be operated as a vented decorative  (ANS
Z21.60) product by opening flue damper.

SAFETY PILOT

This heater has a pilot with an Oxygen
Depletion Sensor Shutoff System (ODS).
The ODS/pilot is a required feature for vent-
free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.

1.

Remove logs and heater base assem-
bly from carton. 

Note:

 Do not pick up

heater base assembly by the burner.
This could damage heater. Always
handle base assembly by grate.

2.

Remove all protective packaging ap-
plied to logs and heater for shipment.

3.

Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.

LOCAL CODES

Install and use heater with care. Follow all local
codes. In the absence of local codes, use the
latest edition of The National Fuel Gas Code
ANS Z223.1
, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

Note: 

Where listed vented decorative logs

are required, thermostat models are not per-
mitted.

Flame-Max

®

Golden Oak Logs T-Stat

Control Knob

Piezo Ignitor

One Piece
Log Set

Base Assembly

 CAUTION: Do not remove the

metal data plates from the grate
assembly. The data plates contain
important product information.

UNPACKING

Содержание FLAME-MAX

Страница 1: ...hanyelectricalswitch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call...

Страница 2: ...s never op erate this heater with glass doors closed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace open ing has vents at the bottom...

Страница 3: ...rs The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater has a piezo ignitor This system requires no matches batteries or other sources to light heater...

Страница 4: ...hods helpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight a...

Страница 5: ...ustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _...

Страница 6: ...ation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilation Ai...

Страница 7: ...heater IMPORTANT Vent freeheatersaddmois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air f...

Страница 8: ...sory GA6050 GA6052 or GA6053 see Acces sories page 29 18 Model Noncombustible material OK Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot ex...

Страница 9: ...e between mantel shelf and top of fireplace opening a hood is not required see Figure 6 Determining Minimum Mantel Clearance When Using a Hood If minimum clearances in Figure 6 are not met you must ha...

Страница 10: ...guard against sooting Raise fireplace floor with noncombustible mate rial Make sure material is secure CAUTION Do not pick up heater base assembly by the burner This could damage heater Only handle b...

Страница 11: ...ocal codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur WARNING Never connect heater to private non utility gas wells...

Страница 12: ...vidual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressur...

Страница 13: ...Piece Log Set Figure 18 Installing Vintage Oak One Piece Log Set Top View One Piece Log Set Burner One Piece Log Set Burner U shaped Cutout in Chassis Chassis WARNING Failuretoposition thepartsinaccor...

Страница 14: ...r window to vent smell This will only last a few hours Note Home owners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there m...

Страница 15: ...s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob...

Страница 16: ...repairs Until repairs are made light pilot with match To light pilot with match see Manual Light ing Procedure 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds rele...

Страница 17: ...ware store or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t...

Страница 18: ...oose at con trol valve 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holdi...

Страница 19: ...mum installation clear ances see pages 7 through 9 4 Clean burners see Cleaning and Mainte nance page 17 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or...

Страница 20: ...1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve...

Страница 21: ...ry Mounting Bracket Adhesive backed Mounting Clip Figure 31 Locating Thermostat Sensing Bulb on Masonry Fireplace Thermostat Sensing Bulb Q Q Q Adhesive backed Mounting Clip Thermostat Sensing Bulb Fi...

Страница 22: ...G HEATER VANGUARD FLAME MAX 22 105187 ILLUSTRATED PARTS BREAKDOWN FLAME MAX VINTAGE OAK LOG MODELS VYS18NA VYS24NA AND VYS30NA 4 1 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 2 18 13 19 17 20 18 20 1 20 2...

Страница 23: ...01 Burner Clip 1 12 102963 01 102773 01 102773 01 Burner 1 13 102568 07 102568 07 102568 07 Control Valve 1 14 098508 01 098508 01 098508 01 Valve Retainer Nut 1 15 098354 01 098354 01 098354 01 Cont...

Страница 24: ...TS BREAKDOWN FLAME MAX GOLDEN OAK AND BIRCH LOG MODELS VYD18NA VYBD18N VYD24NA VYBD24N VYD30NA VYBD30N AND VYD36N 4 20 10 11 12 20 7 20 20 5 6 9 8 15 14 16 18 2 17 13 18 3 19 17 1A 1B Note The Golden...

Страница 25: ...01 Burner Clip 1 12 102980 01 102980 01 102772 01 102772 01 102772 01 102772 01 102772 01 Burner 1 13 102568 07 102568 07 102568 05 102568 05 102568 05 102568 05 102568 05 Control Valve 1 14 098508 0...

Страница 26: ...ATURAL GAS LOG HEATER VANGUARD FLAME MAX 26 105187 ILLUSTRATED PARTS BREAKDOWN THERMOSTATICALLY CONTROLLED MODELS VYD18NTA VYD24NTA VYD30NTA 12 1 2 18 16 17 20 10 9 5 11 4 7 6 19 8 21 13 19 14 19 19 3...

Страница 27: ...ip 1 11 102980 01 102772 01 102772 01 Burner 1 12 101329 21 101329 20 101329 20 Thermostat Gas Valve Assembly 1 13 102979 02 102979 01 102979 01 Thermostat Bracket 1 14 098544 01 098544 01 098544 01 T...

Страница 28: ...3 5 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 10 5 Minimum 5 5 5 Shipping Weight 36 lbs 38 lbs 26 lbs Golden Oak and Birch 24 30 and 36 Golden Oak Golden Oak Variable 18 Thermostat 24 and 3...

Страница 29: ...s Too Low pilot will not stay lit burners will have delayed ignition heater will not produce specified heat When Gas Quality Is Bad pilot will not stay lit burners will produce flames and soot heater...

Страница 30: ...related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EX...