DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

®

BHDV34NA, PA

PILOT AND BURNERS

• Remove ember material before cleaning

burners and replace when cleaning is
complete.

• Burner and controls should be cleaned

with compressed air to remove dust, dirt,
or lint.

• Use a vacuum cleaner or small, soft

bristled brush to remove excess dust, dirt,
or lint.logs

 WARNING: Only parts sup-

plied by the manufacturer should
be used when replacing broken
or damaged glass door panel (see
Replacement Parts, page 32). This
glass door panel is a complete
unit. No substitute materials may
be used.

CLEANING AND
MAINTENANCE

If glass has been broken, carefully remove
glass door (see Removing/Replacing Glass
Door,  
page 22). Vacuum all glass pieces
with a shop vac.

 CAUTION: Wear gloves and

safety glasses while handling or
removing broken glass. Do not
remove if glass is hot. Keep chil-
dren and pets away from glass.

 WARNING: Do not operate

fireplace with the glass door re-
moved, cracked, or broken.

VENTING SYSTEM

Conduct annual inspection of the venting
system following these guidelines:

1.

Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced imme-
diately by a qualified service person.

2.

Remove the vent cap and shine a flash-
light into the vent. Remove any foreign
material.

3.

Check for evidence of excessive con-
densation. Continuous condensation
can cause corrosion of caps, pipes, and
fittings and can be caused by having
excessive lateral runs, too many elbows,
or exterior portions of the system be-
ing exposed to cold weather.

4.

Inspect joints to verify that no pipe sec-
tion or fitting has been disturbed and
loosened. Check mechanical supports
such as wall straps for rigidity.

 WARNING: Turn off fireplace

and let cool before cleaning.

 CAUTION: You must keep con-

trol areas, burners, and circulat-
ing air passageways of fireplace
clean. Inspect these areas of fire-
place before each use. Have fire-
place inspected yearly by a quali-
fied service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.

 WARNING: Do not use abra-

sive cleaners as this may damage
glass. Use a nonabrasive house-
hold glass cleaner to clean glass.
Do not clean glass when hot.

  WARNING: Handle glass door

panel with care. Do not strike,
slam, or otherwise abuse glass.
Do not operate fireplace with the
glass door removed, cracked, or
broken.

GLASS DOOR

Glass must be cleaned periodically. During
start-up it is normal for condensation to
form on the inside of the glass causing lint,
dust, and other airborne particles to cling to
the glass surface. During initial start-up a
slight film may form on the glass due to
paint curing. The glass should be cleaned
several times with a non-ammonia, non-
abrasive household cleaner and warm water
after the first two weeks of operation. There-
after, clean the glass two or three times
during each heating season, depending on
the usage and circumstances present. Refer
to Removing/Replacing Glass Door on page
22 of this manual when removing glass door
for cleaning.

Use only the ceramic glass door replace-
ment intended for this fireplace (see Re-
placement Parts
, page 32 for detail on or-
dering). No substitutions may be made. See
Removing/Replacing Glass Door, page 22
for instructions for replacing glass door.

• If you remove logs for cleaning, refer to

Installing Logs, Lava Rock, and Glowing
Embers
, page 24, to properly replace logs.

• Use a vacuum cleaner to remove any car-

bon buildup on logs.

• Replace log(s) if broken. See Replace-

ment Parts on page 32.

• Replace ember material periodically as

needed. See Replacement Parts on page 32.

 CAUTION: Do not vacuum if

pieces are hot.

Содержание BHDV34P(A)

Страница 1: ...ssis tance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal in jury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation ...

Страница 2: ...lass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the fireplace may not have been installed properly Get fresh air at once Have ...

Страница 3: ...at PIEZO IGNITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BHDV Series Glass Door Assembly Blower Adjustment Optional Installation Piezo Ignitor Valve Burner Pilot Assembly Log Set Grate Assembly Lava Rock Glowing Embers Top Louver Panel Lower Louver Panel Vent Opening Nailing Flange Sta...

Страница 4: ...4 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 0 mm Perpendicular walls 6 152mm Floor 0 mm Ceiling to louver opening 42 1067mm Front 36 914mm Top of Standoffs 0 mm See General Venting on page 5 for specific venting clearances FRAMING AND FINISHING Figures 4 and 5 show typical framing of th...

Страница 5: ...ipes and combustible materials is 1 25 mm except where stated otherwise Combustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding Installhorizontalventingwitha1 4 risefor every 12 of run toward the termination You may paint the vent terminal with 450ºF 232ºC heat resistant paint to co ordinate with the e...

Страница 6: ... paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inches 610mm above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches 457mm vent shall not terminate directly above a sid...

Страница 7: ...oper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizon tal run of venting must have 1 4 rise for every 12 of run towards the termination NOTICE Treatment of firestops andconstructionofthechasemay vary from building type to build ing type These instructions are ...

Страница 8: ... to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide straight into matching slots on the male ends of adjacent pipes and fit tings All connections must be sealed with high temperature silicone sealant as specified in the second warning state ment on page ...

Страница 9: ...of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At tach the vent cap with four wood screws supplied see Figure 13 Note Re place the wood screws with appropri ate fasteners for stucco brick concrete or other types of siding For vinyl siding use vinyl...

Страница 10: ...with corner installation UP Horizontal Venting See information in Figure 17 for Vertical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting Note Figure 16 applies to rigid venting only BGFVK Vent Kit Shown recommended for use with cabinet mantels BVK Vent Kit Shown BFGFVK and FGFVK Vent Kits Shown Horizontal Termination Configurations Figures 16 through 20 show d...

Страница 11: ... max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termination Configuration for Rigid Venting Using Two 90 Elbows Figure 20 Horizontal Termination Configuration for Rigid Venting Using Two 90 Elbows with Termination at 90 with Fireplace Continued ...

Страница 12: ...d clearances air space to combus tibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of the venting system and any maximum hori zontal offset limitations Offsets must fall within the parameters shown in Figure 8 on page 6 2 Set the fireplace in desired location Drop a plumb line down from the ceil ing ...

Страница 13: ...ntally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold the resulting flaps over the roof sheathing see Figure 24 Apply a bead of non hardening mastic around the top edges of the support box to make a seal between the box and the roof Nail in place wit...

Страница 14: ...VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Venting Configuration Using Two 90 Elbows RVF Kit Shown Note Install restrictor into 4 collar of stove as shown Note Install restrictor into 4 collar of stove as shown ...

Страница 15: ...ial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustable 7 12 Galvanized Coaxial Pipe 6 pcs D1050 7 x 6 Galvanized Coaxial Pipe 6 pcs D2000 7 x 90 Elbow 6 pcs D2010 7 x 45 Elbow 6 pcs D2020 7 x 30 Elbow 6 pcs D2030 7 x 60 Elbow 6 pcs D3000 Wall Strap Offset Support 6 pcs D3010 Storm Collar 6 pcs D3020 Wall Thimble 6 pcs D3040 Vertical ...

Страница 16: ...stall this fireplace as your primary heat source If you have acentralheatingsystem youmay run system s circulating blower while using fireplace This will help circulate the heat through out the house In the event of a power outage you can use this fireplace as a heat source Note Your fireplace is designed to be used inzeroclearanceinstallations Wallorfram ing material can be placed directly agains...

Страница 17: ...e see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is recessed and or pre wired a qualified installer must make all elec trical connections for the outlet kit included with the fireplace Figure 30 Mounting Blower to Firebox Top Mounting Tab Exhaust Port WAR...

Страница 18: ... alternative to test gauge connection Pur chase the A G A design certified manual shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply Follow all local codes CAUTION For propane LP units never connect heater di rectly to the propane LP supply This heater requires an external regulator notsupplied Installthe external regulator between the heater a...

Страница 19: ...ne provided by installer from manual shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup ply to control valve see Figure 36 4 Check all gas connections for leaks See Checking Gas Connections CONNECTING FIREPLACE TO GAS SUPPLY FIREPLACE INSTALLATION Continued Flexible Gas Line from Manual Shutoff Valv...

Страница 20: ...f valve see Figure 37 2 Open propane LP supply tank valve for propane LP fireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in the OFF position 4 Check all joints from manual shutoff valve to thermostat gas valve see Fig ure 38 for propane LP or Figure 39 for natural Apply commercial leak test so lution to all gas joints Bub...

Страница 21: ...uch as lamps direct sunlight fireplace or heat and air conditioning ducts 5 Gently remove the cover of the ther mostat from the base Grasp the sides of the cover firmly and pull to separate from the base 6 Feed the electrical wires through the rectangular slots from the back on each side of the base see Figure 42 WARNING Do not connect thisthermostattoapowersource Electrical shock and or fire haz ...

Страница 22: ...rminal wires to a 9 volt alka line battery not included Place bat tery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 45 Installing Alkaline Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal Wires Remote Control Unit Battery Housing Installing 9 Volt Alkaline Battery into Receiver 1 Open bottom louver and locate the switch bracket on ...

Страница 23: ...e 48 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using the same method described in step 3 6 Slide the right retainer bracket against the right side brick panel Loosely se cure the bracket screw This secures the right side brick panel 7 Install rear brick panel Rest bott...

Страница 24: ...or page22 Installlogsaccordingto the following instructions WARNING Failure to position thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury 1 Place log 1 back log on top of grate Make sure the notches in the bottom of the log fit over the grate see Figure 50 2 Restlog 2 largefrontlog onthepinson...

Страница 25: ...d LO The burners will turn on and off automatically to maintain the comfort level you select The ideal comfort setting will vary by household depending upon the amount of space to be heated the output of the central heating system etc NOTICE You must light the pilot before using the hand held re mote control unit See Lighting Instructions 6 Wait five 5 minutes to clear out any gas Then smell for g...

Страница 26: ...e the blower controls by opening the lower louver panel on the fireplace Blower controls are located on the left side of the switch bracket to the left just inside the louver panel Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON setting and an OFF setting The blower will only run when the switch is in the ON position In the OFF position the blower will n...

Страница 27: ...spect the flames after installationtoensureproperinstallationand performance Figure 59 shows a typical flame pattern for BHDV34NA and BHDV34PA If burner flame pattern differs from that described turn fireplace off see To Turn Off Gas to Appliance page 25 see Troubleshooting pages 29 through 31 Figure 58 Pilot Assembly Figure 59 Typical Flame Pattern for models BHDV34NA and BHDV34PA Thermocouple Th...

Страница 28: ...rigidity WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each use Have fire place inspected yearly by a quali fiedserviceperson Fireplacemay need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc WARNING Do not use ab...

Страница 29: ...loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located behind the mounting bracket 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace pilot assembly 7 Replace pilot assembly 1 Turn on gas supply or open manual shuto...

Страница 30: ...rner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 28 or replace burner orifice 1 Adjust the log set so that the flame does not excessively impinge on it 2 Inspect the opening at the base of the burner to see that it is NOT packed with any type of material 1 This is common If noise is excessive cont...

Страница 31: ...et blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark residue on logs or inside of fireplace REMEDY 1 Locate and correct all leaks see Check ing Gas Connections pages 19 and 20 1 Fireplace has been tested for up to 40mph winds However extreme con dition...

Страница 32: ...sconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarrantycoveragefor parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can not supply original replacement part s call DESA International s Technical Service...

Страница 33: ...sure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges or 817 x 873 x 470mm 817 x 873 x 470mm stand offs Carton 37 x 40 x 21 37 x 40 x 21 940 x 1016 x 533mm 940 x 1016 x 533mm Weight lbs kg Fireplace 123 lbs 56 kg 123 lbs 56 kg Shipping 126 lbs 57 kg 12...

Страница 34: ...G3004W Series Off White Paint Thehearthbasecreatesahandsomeriserfor the fireplace cannot be used with corner mantel Dimensions WxHxD 58 x61 2 x289 16 CORNER MANTEL GM200F Series Walnut Stained Hardwood Veneer GM201U Series Unfinished GM202F Series Stained Oak Veneer Shown with optional laminate mantel trim accessory Dimensions WxHxD 60 7 8 x 48 3 4 x 345 8 HEARTH BASE TRIM KIT Not Shown For Use Wi...

Страница 35: ...lation and removal quick and easy They are designed to go at the top and bottom of the glass door on BHDV units Note Remove the plastic film covering on strips before installing on fireplace BRICK LINER D8037A Not Shown This brick liner adds a touch of style to your direct ventfireplaceandcomeswitheasyto follow instructions for installation WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allow...

Страница 36: ...DV34NA PA ILLUSTRATED PARTS BREAKDOWN BHDV34NA BHDV34PA 48 1 2 3 4 6 6 36 5 5 6 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 31 1 31 4 31 2 31 3 33 32 32 34 35 40 37 38 41 39 44 42 43 6 46 45 47 ...

Страница 37: ...lot Propane LP 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burner Natural 1 104504 02 Burner Propane LP 1 26 104506 01 Orifice Natural 1 104506 02 Orifice Propane LP 1 KEY NO PART NUMBER DESCRIPTION QTY 27 104507 01 Brass Elbow 1 28 104508 01 Brass Fitting 2 29 10...

Страница 38: ...s related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THISEXPRESS WARRANTYEXCLUDESANYANDALLOTHEREXPRESSEDWARRANTIESANDLIMITSTHEDURATIONOFANYANDALLIMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR 4 YEARS ON ALL COMPONENTS FROM THE DATE OF F...

Отзывы: