Vanguard BHDV34N(A) Скачать руководство пользователя страница 16

16

105454

DIRECT-VENT FIREPLACE (NATURAL/PROPANE)

®

INSTALLING OPTIONAL
BLOWER ACCESSORY

IMPORTANT

: For clarity, gas valve assem-

bly and grate/burner assembly are not shown
in Figures 30 through 33, page 17. They will,
however, be in your fireplace when you are
installing the blower. Also for clarity the
firebox is shown with dotted lines.

1.

Open lower louver panel or remove for
easier access.

2.

Place the blower against the lower rear
wall of firebox outer wrapper with the
exhaust port directed upward. Align the
holes in the top mounting tabs of blower
with holes in wall of wrapper (see Fig-
ure 30, page 17). Using the two screws
provided, mount blower and tighten
screws securely.

Note:

 For DA3610T, make sure the

thermal switch is comfortably under the
back of the firebox as shown in Figure
31, page 17.

3.

Be sure to securely attach all wire ter-
minals to terminals on blower motor
(and thermal switch where applicable)
and that the screw retaining the green
ground wire is tight.

4.

Remove screws securing the plate con-
taining the ON/OFF switch to the bot-
tom of the firebox and set aside.

5.

Place speed control against back of this
plate and push the plastic control shaft
through opening (see Figure 32, page 17).

6.

While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise
until tight against the plate. Place control
knob provided onto shaft (see Figure 32,
page 17).

7.

Replace plate containing switches and
tighten screws securely.

NOTICE: If installing blower in an
existing fireplace with gas con-
nections, shut off gas supply and
disconnect heater from gas sup-
ply. Contact a qualified service
person to do this.

CHECK GAS TYPE

Use proper gas type for the fireplace unit
you are installing. If you have conflicting
gas types, do not install fireplace. See dealer
where you purchased the fireplace for proper
fireplace according to your gas type.

FIREPLACE
INSTALLATION

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

NOTICE: A qualified service per-
son must install fireplace. Follow
all local codes.

 CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

Note: 

Your fireplace is designed to be used

in zero clearance installations. Wall or fram-
ing material can be placed directly against
any exterior surface on the rear, sides, or top
of your fireplace, except where stand-off
spacers are integrally attached. If stand-off
spacers are attached to your fireplace, these
spacers can be placed directly against wall
or framing material. See framing details on
page 4.

Place the fireplace into position and shim
with noncombustible material if needed.
Nail the side flanges to the framing to secure
the unit in place. There are two floor brack-
ets included with each unit. Use these as an
alternative method of securing the fireplace.

IMPORTANT: 

Make sure fireplace is level

before securing. If fireplace is not level it
will not work properly.

Attaching Thermal Switch to
DA3610T Thermostatically
Controlled Blower

When installing the DA3610T thermostati-
cally controlled blower accessory, you must
first secure the thermal switch to the blower.

1.

Remove the two hex head screws on the
blower assembly as shown in Figure 29.

2.

Place the green wire between the bot-
tom hole on the thermal switch bracket
and the bottom hole on the blower as-
sembly.  Insert one of the hex screws
into all three pieces and tighten.

3.

Insert the top screw through the ther-
mal switch bracket and into the blower
assembly. Tighten screw.

4.

Connect the blue wire on the blower
assembly to the right side of the ther-
mal switch.

5.

Connect the black wire to the left side
of the thermal switch.

Installing GA3700/DA3610T
Blowers

Figure 29 - Attaching Thermal Switch to DA3610T Thermostatically Controlled
Blower Accessory

Blower Assembly

Blue Wire

Green Wire

Black Wire

White Wire

Hex Head
Screws

Thermal Switch
with Bracket

Содержание BHDV34N(A)

Страница 1: ...efer to this manual for correct in stallation and operational procedures Forassistance or additional information consultaqualifiedinstaller service agency or the gas supplier This appliance may be ins...

Страница 2: ...glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poi...

Страница 3: ...ITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BHDV Series Glass Door Assembly Blower Ad...

Страница 4: ...ure 3 34 1 2 34 3 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 0 mm Perpendicular walls 6 152mm Flo...

Страница 5: ...pe cifically approved for this fireplace Minimum clearance between vent pipes and combustible materials is 1 25 mm except where stated otherwise Combustible material may be flush with the top front of...

Страница 6: ...de walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inche...

Страница 7: ...proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizon tal...

Страница 8: ...appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slide straight i...

Страница 9: ...dge of the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintain...

Страница 10: ...on for use with corner installation UP Horizontal Venting See information in Figures 17 and 18 for Vertical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting BGFVK...

Страница 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Страница 12: ...ce to combus tibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of the venting system and any maximum...

Страница 13: ...e Figure 23 Align the support box vertically and horizontally using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the sup...

Страница 14: ...d Venting Configuration With No Horizontal Run VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Ve...

Страница 15: ...xial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustable 7 12 Galvanized Coaxial Pipe 6 pcs D1050 7 x 6 Galvanized Coaxial Pipe 6 pcs D2...

Страница 16: ...un system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source NOTICE A quali...

Страница 17: ...the right side see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system insta...

Страница 18: ...con nector if allowed by local codes not provided AnA G A design certifiedmanualshutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the A G A design certifie...

Страница 19: ...ne provided by installer from manual shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup ply to contr...

Страница 20: ...e Figure 37 2 Open propane supply tank valve for propane fireplace or main gas valve lo cated on or near gas meter for natural gas fireplace 3 Make sure control knob of fireplace is in the OFF positio...

Страница 21: ...h as lamps direct sunlight fireplace or heat and air conditioning ducts 5 Gently remove the cover of the ther mostat from the base Grasp the sides of the cover firmly and pull to separate from the bas...

Страница 22: ...ve battery cover on back of re mote control unit 2 Attach terminal wires to a 9 volt bat tery not included Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figu...

Страница 23: ...4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using the same method descr...

Страница 24: ...s for fireplace model numbers WARNING Failure to position thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or pe...

Страница 25: ...ort level between HI and LO The burners will turn on and off automatically to maintain the comfort level you select The ideal comfort setting will vary by household depending upon the amount of space...

Страница 26: ...e left just inside the louver panel Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON setting and an OFF setting The blower will only run when the switch is i...

Страница 27: ...pect the flames after installationtoensureproperinstallationand performance Figure 60 shows a typical flame pattern for BHDV34N A and BHDV34P A If burner flame pattern differs from that described turn...

Страница 28: ...G Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before each use Have f...

Страница 29: ...n loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut ho...

Страница 30: ...warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas company 3 Clean burner see Cleaning and Maintenance page 28 or replace burner orifice 1...

Страница 31: ...es at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during...

Страница 32: ...n servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Red Variable Fan Switch Fan Switch N O Black Black Green White On 110 115 V A C Blo...

Страница 33: ...ssure 3 5 w c 10 0 w c Minimum Inlet Supply Pressure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace 33 x 34 x 18 1 2 33 x 34 x 18 1 2 838 x 940 x 470mm 838 x 940 x 470mm...

Страница 34: ...02W Series Off White Paint Shown with optional base and laminate hearth and mantel trim accessories Dimensions WxHxD 563 4 x483 4 x22 3 4 HARDWOOD HEARTH BASE G3000F Series Walnut Finished G3001U Seri...

Страница 35: ...F STATUS ON LO HI TEMP RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC SERIES For all models Allows the heater to be turned on and off conveniently RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT...

Страница 36: ...OPANE ILLUSTRATED PARTS BREAKDOWN BHDV34N A 1 2 3 4 6 6 36 5 5 6 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 31 1 31 4 31 2 31 3 33 32 32 3...

Страница 37: ...T Pilot Natural 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burn...

Страница 38: ...ROPANE ILLUSTRATED PARTS BREAKDOWN BHDV34P A 1 2 3 4 6 6 36 5 5 6 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 31 1 31 4 31 2 31 3 33 32 32...

Страница 39: ...18 104497 02 SIT Pilot Propane LP 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1...

Страница 40: ...ing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED...