Vanguard B) Скачать руководство пользователя страница 7

7

105539

OWNER’S MANUAL

 WARNING: Read all instruc-

tions completely and thoroughly
before attempting installation.
Failure to do so could result in
serious injury, property damage
or loss of life. Operation of im-
properly installed and maintained
venting system could result in
serious injury, property damage
or loss of life.

 WARNING: Seal all vent con-

nections. Seal only the outer pipe
connections with high temperature
silicone (600

°

F/316

°

 C). Before join-

ing elbows and pipes, apply a bead
of high temperature silicone seal-
ant (GE RTV 106/Loctite RTV 81585)
to the male end of the elbow or
pipe. High temperature silicone
must also be used to re-seal any
connections after maintenance to
venting system.

NOTICE: Failure to follow these
instructions will void the warranty.

INSTALLATION
PRECAUTIONS

Consult local building codes before beginning
the installation. The installer must make sure
to select the proper vent system for installa-
tion. Before installing vent kit, the installer
must read this fireplace manual and vent kit
instructions.

Only a qualified service person should in-
stall venting system. The installer must fol-
low these safety rules:

• Wear gloves and safety glasses for

protection

• Use extreme caution when using ladders

or when on roof tops

• Be aware of electrical wiring locations

in walls and ceilings

The following actions will void the war-
ranty on your venting system:

• Installation of any damaged venting

component

• Unauthorized modification of the vent-

ing system

VENTING
INSTALLATION

 WARNING: This gas fireplace

and vent assembly must be
vented directly to the outside.
The venting system must NEVER
be attached to a chimney serving
a separate solid fuel burning ap-
pliance. Each gas appliance must
use a separate vent system. Do
not use common vent systems.

 WARNING: Horizontal sec-

tions of this vent system require
a minimum clearance of 2" from
the top of the pipe and 1" mini-
mum to the sides and bottom.
Vertical sections of this system
require a minimum of 1" clear-
ance to combustible materials on
all sides of the pipe.

• Installation of any component part not

manufactured or approved by DESA
International

• Installation other than as instructed by

these instructions

INSTALLATION PLANNING

There are two basic types of direct-vent
installation:

• Horizontal Termination

• Vertical Termination

It is important to select the proper length of
vent pipe for the type of termination you
choose. It is also important to note the wall
thickness.

For Horizontal Termination:

 Select the

amount of vertical rise desired. The horizon-
tal run of venting must have 1/4" rise for
every 12" of run towards the termination.

NOTICE: Treatment of firestops
and construction of the chase may
vary from building type to build-
ing type. These instructions are
not substitutes for the require-
ments of local building codes. You
must follow all local building
codes .

Note:

 When installing in a chase, you should

insulate the chase as you would the outside
walls of your home. This is especially im-
portant in cold climates. Minimum clear-
ance between vent pipes and combustible
materials such as insulation is 1".

After framing the chase (see Framing and
Finishing
 on page 4) install the vent system
by following the installation instructions.

Installing Vent System in a Chase

A chase is a vertical boxlike structure built
to enclose venting that runs along the out-
side of a building. A chase is not required for
such venting.

Continued

 WARNING: Never run the vent

downward as this may cause ex-
cessive temperatures which
could cause a fire.

You may use one or two 90

°

 elbows in this

vent configuration. See Horizontal Termina-
tion Configurations
 on pages 10 and 11.

For Vertical Termination:

 Measure the dis-

tance from the fireplace flue outlet to the
ceiling. Add the ceiling thickness, the verti-
cal rise in an attic or second story, and allow
for sufficient vent height above the roofline.

You may use one or two 90

°

 elbows in this

vent configuration. See Vertical Termination
Configurations
 on pages 13 and 14.

Note:

 You may use two 45

°

 elbows in place

of a 90

°

 elbow. You must follow rise to run

ratios when using 45

°

 elbows.

For two-story applications, firestops are re-
quired at each floor level. If an offset is
needed in the attic, additional pipe and el-
bows will be required.

You may use a chase with a vent termination
with exposed pipe on the exterior of the
house. See Installing Vent System in a Chase,
below.

Your Vanguard direct-vent fireplace has
been tested for a minimum 3' rise with a
maximum 10" wall thickness. The maxi-
mum horizontal run is 20' with 8' vertical
rise (see Installation for Horizontal Termi-
nation
, page 8). The maximum vertical run
is 30' (see Installation for Vertical Termina-
tion
, page 12).

It is very important that the venting system
maintain its balance between the combus-
tion air intake and the flue gas exhaust.
Certain limitations apply to vent configura-
tions and must be strictly followed.

Содержание B)

Страница 1: ...ocedures For as sistanceoradditionalinformation consult a qualified installer ser vice agency or the gas supplier This appliance may be installed in an aftermarket manufactured mobile home where not p...

Страница 2: ...This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANS NFPA 70 or the Cana dian Electrical C...

Страница 3: ...BDV Series Figure 2 Vanguard Direct Vent Fireplace DDV Series Glass Door Assembly Blower Adjustment Optional Installation ON OFF Switch Piezo Ignitor Valve Burner Pilot Assembly Log Set Grate Assembly...

Страница 4: ...um 1 clearance to combustibles 37 1 2 41 1 2 34 3 4 36 3 4 20 Vertical Termination 19 Horizontal Termination Note Where two numbers are given the top number is exclusive to the 37 Fireplace and the bo...

Страница 5: ...d or Simpson Dura Vent GS venting components or kits spe cifically approved for this fireplace Minimum clearance between vent pipes and combustible materials is 1 25 mm except where stated otherwise C...

Страница 6: ...side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimum of 24 inc...

Страница 7: ...proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of vertical rise desired The horizon tal...

Страница 8: ...ation of pipe and el bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations...

Страница 9: ...ap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At tach the ve...

Страница 10: ...orner installation UP Horizontal Venting See information in Figure 18 for Vertical V and Horizontal H maximums and minimums The same amounts apply for flexible venting Note Figure 17 applies to rigid...

Страница 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 20 Horizontal Termi...

Страница 12: ...e Pay spe cial attention to these installation in structions for required clearances air space to combustibles when passing through ceilings walls roofs enclo sures attic rafters etc Do not pack air s...

Страница 13: ...using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold th...

Страница 14: ...INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 28 Vertical Rigid Venting Conf...

Страница 15: ...le Gal vanized Pipe 7 12 Firestop Support Roof Flashing RTV Silicone Vertical Termination and 26 screws D1000 7 x 12 Galvanized Coaxial Pipe 6 pcs D1010 7 x 24 Galvanized Coaxial Pipe 6 pcs D1020 7 x...

Страница 16: ...you may run system scirculatingblowerwhile using heater This will help circu late the heat throughout the house In the event of a power outage you can use this heater as your primary heat source WARNI...

Страница 17: ...right side see Figure 34 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installati...

Страница 18: ...tive to test gauge connection Pur chase the A G A design certified manual shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply Follow all local code...

Страница 19: ...rough one of the access holes on side of fireplace 3 Attach a 45 flare union gas connector to flexible gas line from gas supply see Figure 37 Connect flare union to flex ible gas line attached to gas...

Страница 20: ...ve see Fig ure 38 2 Open propane LPsupply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is in the O...

Страница 21: ...ard off of the lower bracket see Figure 42 4 To replace glass door follow the above instructions in reverse FIREPLACE INSTALLATION Continued Figure 42 Removing Replacing Glass Door Continued Figure 41...

Страница 22: ...e firebox see Figure 43 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel usi...

Страница 23: ...s instructed Do not modify logs Only use logs supplied with fireplace Removeglassdoor SeeRemoving Replacing GlassDoor page21 Installlogsaccordingto instructions for fireplace model numbers Fireplace M...

Страница 24: ...see Figure 51 3 Place log 3 crossover assembly onto the front right pin on front burner with the crossover log resting in notch on back log see Figure 52 4 Place lava rock along sides and front of fir...

Страница 25: ...ing 8 Turn gas control knob counterclock wise to PILOT 9 Push in gas control knob all the way and hold Immediately light the pi lot by repeatedly depressing the piezo spark ignitor until a flame appea...

Страница 26: ...e the louver panel Both the GA3700 manual blower and the DA3610T thermostatically controlled blower have an ON setting and an OFF setting The blower will only run when the switch is in the ON position...

Страница 27: ...d Check mechanical supports such as wall straps for rigidity WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of firep...

Страница 28: ...mocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dr...

Страница 29: ...om line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 27 or replace burner orifice 1 Adjust the log set so that the flame does not...

Страница 30: ...og placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF po...

Страница 31: ...ng controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarrantycoveragefor parts replac...

Страница 32: ...c Minimum Inlet Supply Pressure 4 5 w c 11 0 w c 4 5 w c 11 0 w c Dimension Inches mm HxWxD Fireplace 33 x 37 x 18 1 2 33 x 37 x 18 1 2 35 x 41 x 18 1 2 35 x 41 x 18 1 2 838 x 940 x 470mm 838 x 940 x...

Страница 33: ...al quick and easy They are designed to go at the top and bottom of the glass door on BDV units Note Remove the plastic film covering on strips before installing on fireplace BRICK LINER D8037A 37 D804...

Страница 34: ...3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 42 34 3 34 2 34 4 34 1 35 36 35 37 38 5 5 5 50 51 39 45 46 35 47 48 49 44 6 41 40 43...

Страница 35: ...4502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burner 1 26 104506 01 Orifice 37 1 104506 03 Orifice 41 1 27 104507 01 Brass Elbow 1 28 104508 01 Brass Fitting 2 29 104509 01 Aluminum...

Страница 36: ...STRATED PARTS BREAKDOWN BDV37P A B BDV41P A B 1 2 3 4 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 42 34 3 34 2 34 4 34 1 35 36 35 37...

Страница 37: ...23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 02 Burner 1 26 104506 02 Orifice 37 1 104506 04 Orifice 41 1 27 104507 01 Brass Elbow 1 28 104508 01 Brass Fitting 2 29 104509 01 Alu...

Страница 38: ...KDOWN DDV37N A B DDV41N A B 1 2 3 4 5 5 5 6 6 5 6 7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 33 34 35 36 37 38 47 39 1 39 2 39 3 40 40 40...

Страница 39: ...r Natural 37 1 104505 01 Rear Burner Natural 41 1 27 104488 01 Burner Manifold 1 28 104489 01 Burner Gasket 1 29 104506 04 Orifice 37 1 104506 05 Orifice 41 1 30 104506 05 Orifice 1 31 104507 01 Brass...

Страница 40: ...7 7 8 9 10 11 Included in Hardware Pack 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 33 34 35 36 37 38 47 39 1 39 2 39 3 40 40 40 41 55 54 55 54 59 6 59 56 57 58 55 46 49 45 6 33...

Страница 41: ...Rear Burner LP 41 1 27 104488 02 Burner Manifold 1 28 104489 01 Burner Gasket 1 29 104506 07 Orifice 37 1 104506 15 Orifice 41 1 30 104506 06 Orifice 37 1 104506 09 Orifice 41 1 31 104507 01 Brass El...

Страница 42: ...sts related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THISEXPRESS WARRANTYEXCLUDESANYANDALLO...

Отзывы: