Vanguard ARISTOCRAT V36EC2 Скачать руководство пользователя страница 7

7

55504

Figure 23

12 

1

/

4

" REF

6"
REF

33 DEG

MINIMUM 12"

3"
NOM

6" MINIMUM

1

/

2

"

MAX

TOP OF
LOUVERED
OPENING

COMBUSTIBLE
MATERIAL

SAFE ZONE FOR
PROJECTION OF
COMBUSTIBLE
MATERIALS

NOTE: DRAWING NOT
TO SCALE

UPPER
SECTION OF
FIREPLACE

DAMPER

WEIGHT

TO CLOSE

DAMPER

TO OPEN
DAMPER

NOTE:

  Firebox must be wired to the house electrical system in

order for the blowers to operate. This blower system does not require
a wall switch. Refer to the VCBK3 blower assembly installation
instructions for details.

Electrical connections are made through the cover on the right side
of the firebox as illustrated in Figure 21.  Use 14 AWG copper wire
for all connections.  Be certain the firebox is properly grounded to the
green wire.

BLOWER
SWITCH

GROUND SCREW

ELECTRICAL
COVER PLATE

STRAIN RELIEF

Figure 20

Figure 21

10', 14 GA. W/GROUND
ROMEX ADDED TO U.L.
LISTED (MH11306)
FIREPLACE AT THE
FACTORY

COVER PLATE WITH
STRAIN RELIEF

TO WALL SWITCH

EXISTING “J” BOX
IN FIREPLACE

WIRE NUT (TYP.)

FINISHING YOUR FIREBOX

Combustible materials may make direct contact with the sides and

the top of the firebox face.  It is important that combustible materials
do not overlap the face itself.  Brick, tile or other noncombustible
materials may be applied to the face provided that any gap between
the material around the firebox opening is caulked to prevent the
seepage of combustible products.

CAUTION:  DO NOT COVER UP THE TOP OR BOTTOM
FACE LOUVERS.

Figure 22

MANTEL

A mantel may be installed if desired (see Figure 22) for minimum
heights above and beyond opening of firebox face.

Woodwork, such as wood trim and mantels, and other combustible
material, shall not be placed within 6 inches of a firebox opening.
Combustible material above and projecting more than 1 

1

/

2

 inches

from a firebox opening shall not be placed less than 12 inches from
the top of the firebox opening.  NFPA Standard 211 sections 7-3.3.3.

DAMPER OPERATION

The flue gas damper is located inside the firebox similar to a

conventional masonry fireplace. Look within the top of the firebox
and locate the damper handle extending from the damper (see Figure
23) for operating the damper. This can be easily accomplished with
a firebox poker.

FIRE:

  Use seasoned hardwood or when using vent-free or

decorative gas appliance use natural or propane/LP gas.

Содержание ARISTOCRAT V36EC2

Страница 1: ...NG GREEN KY 42102 9004 55504 Rev B 08 99 ARISTOCRAT MODEL V36EC2 LOUVERED CIRCULATING WOOD BURNING FIREBOX 21 3 8 42 35 36 41 23 1 4 0 IN TO TOP SPACER AIR KIT K O GAS LINE K O 3 4 AIR SPACE BACK AND...

Страница 2: ...ar sidewall A 2 inch minimum air space clearance between combustible materials and the chimney must be absolutely maintained A 16 1 2 inch inside chase dimension is recommended as a minimum size A 3 4...

Страница 3: ...rt if properly locked It is not necessary to add screws to keep the chimney together FIRESTOP SPACERS VFS 8DM Firestop spacers are required at each point where the chimney penetrates a floor or ceilin...

Страница 4: ...ar opening must be cut STEP 1 Determine the center point through which the pipe will penetrate the roof STEP 2 Determine the pitch of the roof Pitch is the distance the roof drops over a given span us...

Страница 5: ...TION TEMPORARILY DO NOT DISCARD REMOVE GAS CONDUIT COVER Figure 14 OUTSIDE OF FIREPLACE GAS LINE CONDUIT REPACK INSULATION INCOMING 1 2 BLACK IRON PIPE PROVIDE ENOUGH THREADED END FOR FITTING CONNECTI...

Страница 6: ...handling during installation These should be sealed with non combustiblematerials Ifthefireboxismountedonaraisedplatform insulate below the platform to prevent the entry of cold air through the firebo...

Страница 7: ...e sides and the top of the firebox face It is important that combustible materials do not overlap the face itself Brick tile or other noncombustible materials may be applied to the face provided that...

Страница 8: ...8DM 0 to 6 12 V12F 8DM 6 12 to 12 12 EMBER PROTECTOR EP 36 ROUND TOP TERMINATION VRTL 8DM VRTTL 8DM VADS 8DM ECONO TOP TERMINATION VETO 8DM VETLO 8DM GLASS DOOR KIT VDG36E Brushed Brass VDP36E Polishe...

Отзывы: