CAUTION
Failure to comply with the following can cause erratic operation of the control and/or unit:
• Never install more than one main wall control per ventilation unit.
• Keep control low voltage wiring at least 1 foot (305 mm) away from motors, lighting balast, light dimming circuit
and power distribution panel. Do not route control wiring alongside house power wiring.
• Ensure the wires are securely connected.
Unplug the ventilation unit.
VC0217
VC0219
Unscrew the screw located on the
underside of the wall control.
Separate the front module from the
mounting plate by lifting its bottom
part.
12V D- D+ Gnd
Strip the end of the cable to access
the 4 wires (about 3"). Strip the end
of each wire (about 1/4"). Connect the
wires to the terminals, regardless of
the wire color. Note which wire color
has been chosen for each terminal.
VC0218
Install the front module on the
mounting plate. Fix both parts by
screwing the screw on the underside
of the wall control.
Be careful not to pinch wires when reinstalling the
front module on the mounting plate.
CAUTION
Plug the ventilation unit in power source.
This control is compatible with all AI and N series units.
VC0245A
P
RELIMINARY
SETTINGS
VC0246A
Set the Language and the Day and time screens following your preferences.
23840 rev. 02
Perform the electrical connection to the terminal connector of
the unit, as shown below. For more details, refer to the
installation manual of the ventilation unit.
12V D- D+ Gnd
VC0232
NOTE: To avoid miswiring, refer to the notes taken at step
to match the wire color with the right terminal.
W
ALL
CONTROL
REAR
VIEW
NOTE: If the control is to be installed in an electric box, do
not perform steps 3 and 4.
I
NSTALLATION
AND
U
SER
G
UIDE
FOR
A
DVANCED
T
OUCHSCREEN
C
ONTROL
VÄN
EE
PART
NO
. 41303 V
ENMAR
PART
NO
. 41403
READ AND SAVE THESE INSTRUCTIONS
The illustrations in this document are generic; your control appearance may be slightly different from the ones shown.
Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards.
Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally. Always wear safety glasses and gloves while
performing these instructions.
WARNING
!
VC0255
Using the mounting plate, mark the
hole opening and screw locations at
the desired height on the wall.
VC0244A
Ø 3/16", typ.
Cut the hole opening using the mark
previously drawn (1/8" outside the
mark is recommended). Drill both
screw holes (3/16" Ø) in wall and
insert the wall anchors (included).
Fix the mounting plate to the wall using the screws provided.