![vanEE 40E 44263 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/vanee/40e-44263/40e-44263_user-manual_3382693011.webp)
11
H
OW
TO
SET
THE
RELATIVE
HUMIDITY
(RH)
LEVEL
AND
CHOOSE
BETWEEN
OFF
IN
STANDBY
OR
RECIRCULATION
IN
STANDBY
Setting the relative humidity level allows to select the maximum desired indoor humidity level (in
percentage). This value will be used to start the dehumidistat override (air exchange in high speed).
OR
OR
U
SE
UP
OR
DOWN
ARROW
TO
CHANGE
TO
RECIRCULATION
IN
STANDBY
.
Press and hold OK for 3 sec. to access the settings menu. The
backlight will be activated during the entire procedure.
The Relative humidity arrow and value will flash
(default setting: 45%).
Use the UP or DOWN arrow to change the value.
The value changes by 1% increments. Lowest
value: 30%. Highest value: 55%. Still flashing.
Press OK button to accept the new value and go to next setting.
Two lines are flashing to show that OFF¹ is in stand by (default
configuration setting).
Press OK button to accept and quit setting
menu.
Recirculation arrows are turning and rE flashes to show that
RECIRCULATION² is in standby.
Press OK button to accept and quit setting menu.
1
OFF in stand by
: On 20 min/h mode, the ventilation unit is OFF during 40 minutes and exchanges
air with the outdoors on low speed during the remaining 20 minutes of the hour.
This is the default value.
2
RECIRCULATION in stand by
: On 20 min/h mode, the ventilation unit recirculates the indoors air
for 40 minutes on high speed and exchanges air with the outdoors
on low speed during the remaining 20 minutes of the hour.
2.3 Deco-Touch Main Control
(cont’d)
2. Controls