WPIR-EXT
Installation Instructions/User Manual
13
Edition Date: 26.07.2021
Doc ID: I-200478
9. Test procedure
Walk Test Procedure:
1.
Allow 3 minutes of warm up time.
2.
Make sure that the protected area is cleared of all people.
3.
Initialize the "Walk test" mode on your control panel.
4.
Start walking across the detection zone.
5.
Listen to ALARM sound whenever motion is detected (the red LED and the Buzzer also turns ON whenever
motion is detected).
6.
Allow 5 sec. between each test for the detector to stabilize.
7.
Upon installation, the unit should be thoroughly tested to verify proper operation.
8.
Walk across the entire area where coverage is desired. Should the coverage be incomplete, readjust
coverage range or relocate the detector.
NOTE:
Walk Test procedure should be conducted at least once a year, to verify proper operation and range
coverage of the detector.