background image

 

 

 

 

WPIR-EXT 

Two Way Wireless Outdoor Double PIR 

Detector with Anti-masking 

 

 
 
 

INSTALLATION INSTRUCTIONS & USER MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
Edition Date: 01.11.2021 

 

Doc ID: I-200478 

 
 

Содержание WPIR-EXT

Страница 1: ...WPIR EXT Two Way Wireless Outdoor Double PIR Detector with Anti masking INSTALLATION INSTRUCTIONS USER MANUAL Edition Date 01 11 2021 Doc ID I 200478...

Страница 2: ...We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject ther...

Страница 3: ...duction 3 2 Features 3 3 Operation 4 4 Assembly Description 5 5 Installation and Discovery Enrollment Process 7 Select Mounting Location 7 6 Detector Installation 8 7 Discovery Enrollment Process 9 8...

Страница 4: ...allation environment and protection site The WPIR EXT is designed to protect large areas and can easily be installed on walls toprovide a solid protection of the area while rejecting interference from...

Страница 5: ...attery Low signal will be sent When Battery level drops below Cut Off level 2 3V the device will stop functioning and the Red LED will blink for 10 seconds and then turned Off TAMPER Whenever the cove...

Страница 6: ...s a robust detector which includes indication LED prism that can be easily observed from long distance Having a back metal bracket the WPIR EXT can be easily mounted to walls and poles using mounting...

Страница 7: ...al 6 Edition Date 26 07 2021 Doc ID I 200478 Front view Back view with battery 2 LED Detector 9 Battery Cover 4 Upper PIR Element 10 Back Tamper Switch Removal 5 Anti Mask Sensor 6 Lower PIR Element 7...

Страница 8: ...than 10 from perpendicular line Mounting at more than 10 Deviation from horizontal line Facing metal doors Do not install near direct source of heat or air gust Clear all physical obstacles from the...

Страница 9: ...the wall leaving 15cm from all sides for easy installation and maintenance 4 Install the metal bracket on the wall or a pole using either mounting screws or Jubilee clips metal bands 5 Install the det...

Страница 10: ...o observe correct polarity Inserting the batteries starts the discovery process from the device III Enroll the device by configuring the Description Zone Zone Type and other settings in the SPC system...

Страница 11: ...IR EXT Installation Instructions User Manual 10 Edition Date 26 07 2021 Doc ID I 200478 5 Close the battery cover DISCOVERY FAILED Remove the batteries wait for around 10 seconds and repeat the proces...

Страница 12: ...and 180 In order to change the detection beam direction rotate the internal detection element housing to thedesired direction Detection range setting The WPIR EXT detection range may vary between 3m a...

Страница 13: ...tempt is made to mask the lens with a sticker or to put a masking object close to the lens a troublealert will result up to 180 seconds after masking The Red LED will blink and the TROUBLE Tamper will...

Страница 14: ...n to ALARM sound whenever motion is detected the red LED and the Buzzer also turns ONwhenever motion is detected 6 Allow 5 sec between each test for the detector to stabilize 7 Upon installation the u...

Страница 15: ...ssion Alarm Anti Mask Tamper Supervision Low Battery Supervision Time 7 min by default configurable between 1 to 30 minutes Detection Range Configurable from 3m to 12m Installation Height From 0 8m to...