11.2 Connecting a reader to an SPCA210 in Wiegand mode

You can connect a VR series reader in Wiegand mode directly to an SPCA210 door controller.

Wire the connections between the reader and an ACTpro-15xx controller as follows:

AB-+ Terminal block

SPCA210 door controller

Reader 1 block

A

D0

B

D1

-

0V

+

+12V

R Y/T G H Terminal block

SPCA210 door controller

Reader 1 block

R

VD1

Y/T

G

VA1

H

Reader jumper settings

Jumper 1 OFF

Jumper 2 ON top 2 links

Jumper 3 OFF

Mullion Reader VR20 VR50 – Installation Manual

Connecting the VR series reader to SPC

© Vanderbilt 2021

40

A-100410-d

12.02.2021

Содержание VR20M-MF

Страница 1: ...Mullion Reader VR20 VR50 Installation Manual Document ID A 100410 d Edition date 12 02 2021 ...

Страница 2: ...pose other than for which it was delivered to him MIFARE and MIFARE Classic are trademarks of NXP B V MIFARE DESFire are registered trademarks of NXP B V and are used under license Hereby Vanderbilt International IRL Ltd declares that this equipment type is in compliance with the following EU Directives for CE marking Directive 2014 30 EU Electromagnetic Compatibility Directive Directive 2014 53 E...

Страница 3: ...17 5 6 2 Connecting the reader in Wiegand mode 17 5 7 Setting the Jumpers 20 5 8 Setting the Jumpers for OSDP 20 5 9 Setting the Jumpers for Wiegand 21 5 10 Reverse mode Wiegand 23 5 11 Programming a reader for reverse mode transmission 24 5 11 1 Reverting to standard mode Wiegand 24 5 12 Programming a Reverse mode transmission reader for 26 Bit Wiegand 24 5 12 1 Re programming a reverse mode tran...

Страница 4: ...3 Setting the jumpers for OSDP mode 35 10 3 1 Setting the OSDP address for the reader 35 10 4 Connecting an entry reader to ACT in Wiegand mode 36 10 5 Connecting an Entry and an Exit reader to ACT in Wiegand mode 37 10 5 1 Set the jumpers for Wiegand mode 38 11 Connecting the VR series reader to SPC 39 11 1 Connect a single reader to an SPCA210 door controller through an SE1190 OSDP interface 39 ...

Страница 5: ...ication from the reader or the controller they are connected to cannot be compromised The readers are made of hard wearing materials and will endure most weather conditions The readers are easy to mount and can be mounted on a flat surface The readers can be cleaned with most kinds of domestic detergents All readers have a multicolour light frame The VR50M MF has a keypad for PIN code Vanderbilt 2...

Страница 6: ...Classic up to 6 cm MIFARE Plus up to 6 cm MIFARE DESfire EV1 EV2 the card must be held to the reader Indicators 3 x LED red yellow green 1 x Buzzer Multicolour light frame 3 x LED red yellow green 1 x Buzzer Multicolour light frame Keypad No Yes Operating temperature 40 C to 70 C 40 C to 70 C IP rating IP54 IP66 Mounting and connecting on page 12 IK class 08 08 Housing Zinc cast metal bezel with p...

Страница 7: ...Cable Length Cable OSDP 1 km Screened twisted pair For example Belden 9501 Wiegand 30m Screened multicore For example Belden 9538 Mullion Reader VR20 VR50 Installation Manual Technical data Vanderbilt 2021 7 A 100410 d 12 02 2021 ...

Страница 8: ...operate the equipment Performance levels per UL294 are l Destructive attack Level I l Line Security Level I l Endurance Level IV l Standby Level I 2 3 FCC statement Model No FCC ID VR20M MF 2AHDLMULL VR50M MF 2AHDLMULL This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accep...

Страница 9: ... consider any additional country specific local laws safety standards or regulations concerning installation operation and disposal of the product Liability claim l Do not make any changes or modifications to the device l Use only spare parts and accessories that have been approved by the manufacturer Vanderbilt 2021 9 A 100410 d 12 02 2021 ...

Страница 10: ... packaged with the reader 4 1 Reader components 1 Front 6 Tamper base 2 Knockouts x 2 7 Screw for tamper protection 3 Base 8 Mounting holes 4 Hook 19 Upper and lower terminal block locations 5 Location where cables can come through the back 4 2 Reader Components Package contents Vanderbilt 2021 10 A 100410 d 12 02 2021 ...

Страница 11: ... Wiegand upper terminal block 3 Mounting Tamper screws 4 Cover screw 5 Opening tool 6 IP 55 Foam backing for outdoor installation 7 IP 66 Gasket for outdoor installation Mullion Reader VR20 VR50 Installation Manual Reader components and package contents Vanderbilt 2021 11 A 100410 d 12 02 2021 ...

Страница 12: ...e wall with three screws one in the middle at the top of the base and one in each of the corners at the bottom of the base 1 Cable entry through base gasket 2 Tamper screw 3 Tamper base 2 If additional wall removal tamper protection is required fix the screw item 2 into the tamper base item 3 Do not over tighten the screw as this can damage the tamper base 3 Continue to follow the instructions det...

Страница 13: ...f the reader to avoid water channeling to the inside of the reader 5 Attach the base to the wall with three screws one in the middle at the top of the base and one in each of the corners at the bottom of the base 1 Cable entry through base 2 Tamper screw 3 Tamper base 4 Self adhesive foam base 6 If additional wall removal tamper protection is required fix the screw item 2 into the tamper base item...

Страница 14: ...3 Tamper base 4 IP 66 rubber gasket 4 If additional wall removal tamper protection is required fix the screw item 2 into the tamper base item 3 Do not over tighten the screw as this can damage the tamper base 5 Continue to follow the instructions detailed in Connecting the cables on page 17 The reader is automatically tamper protected when removing the front of the reader from the reader base with...

Страница 15: ...entify which of the knockouts the cables should be fed through 3 Use a pliers to pull the knockout away from the base 4 Remove the corresponding knockout on the cover Mullion Reader VR20 VR50 Installation Manual Mounting and connecting Vanderbilt 2021 15 A 100410 d 12 02 2021 ...

Страница 16: ...utomatically tamper protected when removing the front of the reader from the reader base with the help of the opening tool The wall removal tamper is an additional protection against physical attacks 7 Feed the cables through the opening and reinsert the gasket Follow the instructions for Connecting the cables on the next page Vanderbilt recommend sealing the gap that the knockout creates with a s...

Страница 17: ...on For more information on setting the Jumpers in OSDP mode see Setting the Jumpers for OSDP on page 20 For more information on setting the Jumpers in Wiegand mode see Setting the Jumpers for Wiegand on page 21 On the reverse of the front plate Jumper 3 is used to determine EOL see the diagram in Connecting the cables above By default EOL is ON and the reader acts as the last reader on the bus How...

Страница 18: ...ction may alternatively be configured to provide a Yellow input to the reader The Tamper output Yellow input options are mutually exclusive 1This connection is optional When the tamper output option is configured there is no yellow indication input In this instance you can turn on the yellow indication LED by setting both the red and green indication inputs low Both the red and green indication LE...

Страница 19: ...rmine EOL By default the reader has EOL ON EOL is always off in Wiegand mode Please note that you must set the Jumpers to configure your application For more information on setting the Jumpers in Wiegand mode see Setting the Jumpers for Wiegand on page 21 Mullion Reader VR20 VR50 Installation Manual Mounting and connecting Vanderbilt 2021 19 A 100410 d 12 02 2021 ...

Страница 20: ...de 2 Set OSDP addressing or Wiegand formats 3 Set End Of Line EOL status for the reader This indicates the bottom of the reader 5 8 Setting the Jumpers for OSDP The diagrams below show how to position the Jumpers to get the desired functions from the terminal blocks Note that the EOL is ON for a sole reader or for the last reader on the RS485 bus Jumper 1 Vanderbilt 2021 20 A 100410 d 12 02 2021 M...

Страница 21: ...egand or 56 Bit Wiegand Some installations may require transmission in Reverse Mode for 26 Bit Wiegand 32 Bit Wiegand or 56 Bit Wiegand If you are adding this reader to an existing Reverse Mode installation you must follow the procedure to program the reader to Reverse Mode Wiegand For more information please refer to l Reverse mode Wiegand on page 23 If the existing installation uses 26 Bit Wiega...

Страница 22: ...or reverse mode transmission on page 24 37 Bit Yes No 32 Bit Yes Yes Yes Programming a reader for reverse mode transmission on page 24 26 Bit Yes Yes Programming a reader for reverse mode transmission on page 24 Programming a Reverse mode transmission reader for 26 Bit Wiegand on page 24 The diagrams below show how to position the Jumpers to get the desired functions from the terminal blocks Note ...

Страница 23: ... Mode installation you must follow the procedure to program the reader to Reverse Mode Wiegand For more information see Programming a reader for reverse mode transmission on the facing page If the existing installation uses 26 Bit Wiegand you must follow an additional procedure to program the reader to transmit in Reverse Mode 26 Bit Wiegand For more information see Programming a Reverse mode tran...

Страница 24: ... the installation 5 11 1 Reverting to standard mode Wiegand To return the reader to the standard data sequence for Wiegand follow the steps below 1 Remove the Base of the reader from the Front of the reader 2 Power down the reader if connected 3 Connect the Green to the Tamper connection 4 Remove Jumper 1 and Jumper 2 5 Power up the reader The reader beeps the affirmation tone and the green indica...

Страница 25: ... 6 Power down the reader 7 Disconnect the Red input and the Tamper connection 8 Place Jumper 2 in the appropriate position for the number of Weigand bits upper position for 32 Bit lower position for 56 Bit and remove for 37 Bit 9 Power up the reader l The RED indication LED flashes twice if the reader is configured for 26 Bit Wiegand operation l The GREEN indication LED flashes twice if it is conf...

Страница 26: ... in the bottom of the reader front until the snap lock confirms a secure attachment 3 Screw the cover screw see number 4 in Reader Components on page 10 into the bottom of the reader If you are using the IP66 gasket hold the tab at the bottom of the IP66 gasket clear of the reader while closing After closing the reader press the tab up into the correct sealed position Vanderbilt 2021 26 A 100410 d...

Страница 27: ...n the tab at the bottom of the IP66 gasket before inserting the opeining tool 1 Remove the cover screw 2 Insert the opening tool in the slot between the base and the front and push gently upwards 3 Use the opening tool to pull the reader outwards and upwards Vanderbilt 2021 27 A 100410 d 12 02 2021 ...

Страница 28: ...ards to disengage from the hook at the top 7 2 To remove the terminal block 1 Push the terminal block gently away from the cable entry hole 2 Tilt the terminal block away from the base Mullion Reader VR20 VR50 Installation Manual Disassembling the reader Vanderbilt 2021 28 A 100410 d 12 02 2021 ...

Страница 29: ...r card read 100 milliseconds Reception for card time before the same card will be detected in the field again Inactive Min background illumination 12 Max background illumination 255 Off line indication Yes Buzzer volume for key press 2 Buzzer volume for card read 2 System sound 10 8 1 3CT Tool To change the default configuration of the reader use the 3CT tool You can purchase the 3CT tool as a sep...

Страница 30: ...w freetos org 8 2 Setting burst mode using the keypad The default burst mode is 4 bit This can be changed to 8 bit To change from 4 bit to 8 bit burst 1 Power up the reader while holding the X key The red and green indicators alternately turn on 2 Press the key sequence 1818 to specify that 8 bit burst is required 3 Hold down the key until you hear the two tone affirmative beep 4 To change back to...

Страница 31: ...M is as follows RIM DRI ERI VRxx MF 12 V 0V Tx A Rx B SiPass integrated can support both the VR and NGCR readers on the same OSDP bus 9 2 Setting OSDP address for the reader You can set the reader address to 1 default setting 2 or programmed with a value from 1 to 8 using the Jumper Place the Jumper in one of the three positions shown in the diagram below to achieve the desired address Additional ...

Страница 32: ...note that a new reader will always get the next free bus address For example if a reader with bus address 5 is removed and a new reader is installed the new reader gets address 5 9 3 Connecting the reader to SiPass integrated in Wiegand mode For more detail on connecting the reader to SiPass integrated via Wiegand see Connecting the reader in Wiegand mode on page 17 Mullion Reader VR20 VR50 Instal...

Страница 33: ... mode on page 36 l Connecting an Entry and an Exit reader to ACT in Wiegand mode on page 37 l Setting the Jumpers for Wiegand mode on page 1 10 1 Connecting a single reader to ACT in OSDP mode An ACTpro 1520 controller can support all VR series readers on the same OSDP bus l For OSDP mode set the jumpers on the VR series reader as shown in 1 2 3 in the diagram l Set the End Of Line EOL jumper on t...

Страница 34: ...ame OSDP bus A B C Address 1 Address 2 Address 3 End Of Line Jumper 1 ON Jumper 1 ON Jumper 1 ON Jumper 2 OFF top 2 links Jumper 2 OFF top 2 links Jumper 2 OFF top 2 links Jumper 3 OFF Jumper 3 OFF Jumper 3 ON l Set the End Of Line EOL jumper on the ACT pro controller as shown Wire the connections between the VR series readers and an ACTpro 1520 controller as follows VRxx MF AB Terminal block ACTp...

Страница 35: ... is possible to select Jumper 2 in the OFF position in OSDP mode which is automatically selecting the address depending on the number of readers added to the system Therefore it is not necessary to select a specific OSDP address for each reader via the Jumper setting 10 3 1 Setting the OSDP address for the reader In the OSDP reader section of the ACTPro Software use the auto discovery function to ...

Страница 36: ... block ACTpro 1520 12 24 V 0V GND A DATA D0 B CLOCK D1 R Y T G H Terminal block ACTpro 15xx R RED Y T G GREEN H For more information on how to correctly locate and fit the terminal blocks see Connecting the cables on page 17 Cable length guide Mode Max Cable length Cable OSDP 1 km Screened twisted pair For example Belden 9501 Mullion Reader VR20 VR50 Installation Manual Connecting VR20 VR50 reader...

Страница 37: ...erminal block ACTpro 1520 A DATA D0 B CLOCK D1 0V GND 12 24 V R Y T G H Terminal block ACTpro 15xx R RED Y T G GREEN H Connect Exit reader to ACTpro 15xx controller Wire the connections between an Exit reader and an ACTpro 15xx controller as follows AB Terminal block ACTpro 1520 A SENSE B CLOCK D1 0V GND 12 24 V Vanderbilt 2021 37 A 100410 d 12 02 2021 Mullion Reader VR20 VR50 Installation Manual ...

Страница 38: ...jumpers for Wiegand mode ENTRY reader EXIT reader Jumper 1 OFF Jumper 1 OFF Jumper 2 ON top 2 links 32 bit Jumper 2 ON top 2 links 32 bit Jumper 3 OFF Jumper 3 OFF Cable length guide Mode Max Cable length Cable Wiegand 30m Screened multicore For example Belden 9538 Mullion Reader VR20 VR50 Installation Manual Connecting VR20 VR50 readers to ACT Vanderbilt 2021 38 A 100410 d 12 02 2021 ...

Страница 39: ...an connect a single VR series reader in OSDP mode to an SPCA210 door controller A B Terminal block SPCA210 door controller SE1190 OSDP interface A A B B 0V 12V DP51 TA Reader jumper settings Jumper 1 ON Jumper 2 OFF Jumper 3 ON Cable length guide Mode Max Cable Length Cable OSDP 500m Screened twisted pair For example Belden 9501 Vanderbilt 2021 39 A 100410 d 12 02 2021 ...

Страница 40: ...an ACTpro 15xx controller as follows AB Terminal block SPCA210 door controller Reader 1 block A D0 B D1 0V 12V R Y T G H Terminal block SPCA210 door controller Reader 1 block R VD1 Y T G VA1 H Reader jumper settings Jumper 1 OFF Jumper 2 ON top 2 links Jumper 3 OFF Mullion Reader VR20 VR50 Installation Manual Connecting the VR series reader to SPC Vanderbilt 2021 40 A 100410 d 12 02 2021 ...

Страница 41: ...n connect 2 VR series reader in Wiegand mode directly to an SPCA210 door controller Reader 1 wiring AB Terminal block SPCA210 door controller Reader 1 block A D0 B D1 0V 12V R Y T G H Terminal block SPCA210 door controller Reader 1 block R VD1 Y T G VA1 H Vanderbilt 2021 41 A 100410 d 12 02 2021 Mullion Reader VR20 VR50 Installation Manual Connecting the VR series reader to SPC ...

Страница 42: ...der 1 block R VD1 Y T G VA1 H Reader 1 and Reader 2 jumper settings Jumper 1 OFF Jumper 2 ON top 2 links Jumper 3 OFF Cable length guide Mode Max Cable length Cable Wiegand 30m Screened multicore For example Belden 9538 Mullion Reader VR20 VR50 Installation Manual Connecting the VR series reader to SPC Vanderbilt 2021 42 A 100410 d 12 02 2021 ...

Страница 43: ...erbilt International Ltd Clonshaugh Business and Technology Park Clonshaugh Dublin D17 KV 84 Ireland vanderbiltindustries com contact Vanderbilt 2021 Data and design subject to change without notice Supply subject to availability Document ID A 100410 d Edition date 12 02 2021 ...

Отзывы: