Engineer programming via the browser
17
Panel status
173
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Communication
The physical status (OK, Fault) and the programmed status (OK, Isolated,
Inhibited) of the keypad cable connection to the expander.
Cabinet Tamper
The physical and programmed status of the expander cabinet tamper.
PACE
Applies only to Keypads with a PACE receiver installed.
Panic
Keypad panic alarm status.
Fire
Keypad Fire alarm status.
Medical
Keypad medical alarm status.
Code Tamper
Keypad PIN tamper alarm status
Performable actions
Restore Alerts
Click the button to restore all alerts on the panel.
Inhibit
Click this button to inhibit a fault condition. The inhibit operation will disable
that fault or zone for one arming period only.
Inhibit operation is not available in Security Grade EN 50131 Grade 3.
Isolate
Click this button to isolate that zone. Isolating a zone will de-activate that zone
until such time as the zone is explicitly de-isolated again. It is recommended
that you exercise caution when isolating zones as those zones will not be
active every time the system is SET.
17.6.2.4
Door Controller Status
1. Select Status > Hardware > X-Bus Status.
2. Select the Door Controllers tab.
A list of detected door controllers is displayed.
Expander ID
This ID number is a unique identifier for the door controller.
!
Содержание SPCK620
Страница 1: ...A6V10276959 Vanderbilt 01 05 2016 SPC42xx 43xx 52xx 53xx 63xx Installation Configuration Manual 3 6 ...
Страница 364: ...23 Appendix ATP Category Timings 364 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 365: ...Appendix 23 ATP Category Timings 365 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 366: ...23 Appendix ATP Category Timings 366 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...
Страница 367: ...Appendix 23 ATP Category Timings 367 Vanderbilt Installation Configuration Manual A6V10276959 01 05 2016 ...