www.vanco1.com
800.626.6445
10
•
To select an EDID Preset for one input
Operation: Long-press EDID for 3 seconds to enter EDID configuration mode, and then press INPUT# + OUTPUT# + ENTER
Example: Invoke the first type of embedded EDID for INPUT 4
PRESS
(Hold for 3 seconds)
INPUT:
OUTPUT:
•
To select an EDID Preset for several inputs
Operation: Long-press EDID for 3 seconds to enter EDID configuration mode, and then press INPUTS# + INPUTS# + ... +
OUTPUT# + ENTER
Example: Invoke the first type of embedded EDID for INPUT 2, 4
PRESS
(Hold for 3 seconds)
INPUT:
OUTPUT:
Output check
Press any output button to check its corresponding input.
Example: Check which one is the corresponding input for output 2. (Presume Output 2 corresponds to Input
1.)
Operation: Press Output 2 button, LCD screen display AV: 1->2 IR: 1->2, and indicators of input 1 and output
2 turn on and last for 3 seconds. Then output 2 corresponds to input 1.
Clear operation
When the output channel is switched, learn EDID data, or set EDID data, press the Clear button to cancel the
operation before ENTER is pressed.
IR Control
By using IR & HDBaseT transmission technology, the matrix has some additional functions as follows:
1) Control displays from the matrix unit location
2) Control sources from each display location
3) Control switching of the matrix unit