Installation Instructions
1. If not already installed lubricate the by‐pass valve o rings with some vegetable oil or silicone grease and
connect the bypass assembly to the Clack WS1 control by sliding the bypass valve firmly into the body of the
Clack WS1. Once bypass is in far enough, hand tighten unions.
(Fig.4)
2. See by‐pass valves. If red valve handles are in‐line with pipe they are in service, not bypass. Move both valves
clockwise (Fig. 8) to the bypass position if not already in bypass.
3. Now install your water pipes to the Clack WS1 bypass end connectors. Make sure inlet is installed to the 'In"
pipe connector on the bypass valve and outlet is on the “Out” connector.
4. Connect some flexible tubing from the drain connection on the Clack WS1 control valve to a suitable drain
such as a septic tank or drain to a sewer complete with air gap. It is OK to run the drain line up and over the
Clack WS1 filter up to 4 feet above the top of the tank. If the drain line will be more than 20 feet, use larger
diameter tubing such as ¾” or 1”. Note that it is desirable to be able to run the drain line into a bucket in order
to test the backwash flow rate in the future. This is why hard piping the drain line is discouraged, however, if you
do use hard PVC piping for the drain line, and you are able to remove the hard PVC drain piping and attach
flexible tubing should you ever desire for testing purposes, it is OK to use rigid PVC pipe for the drain. Make sure
the drain tubing is firmly clamped to the barbed fitting with a hose clamp to prevent leaks.
5. Plug in your Clack WS1 control valve to an outlet.
6. Set Current Time of Day. Press “Set” button until of time of day is displayed. The hour will start to flash. Use
the “up” or “down” arrows to select the hour. Make sure you select AM or PM. PM will have an arrow pointed
at it when selected. Press the “Up” or “Down” button until the correct hour is displayed. Then press the “Set"
button to select the minutes. Press “Set” once more to exit.
7. Press Set and the Up arrow together for about 5 seconds. Set Regeneration Time hour using up and down
arrows not forgetting AM or PM. 2:00AM is the default.