Panel: maximum dimensions 1800x1100 mm (21 kg)
Panel: maximum dimensions 2100x1100 mm (24 kg)
Windmap Belgium
Required ballast | Belgium
General
The ValkTriple® mounting system must be reinforced by means of tiles, which must be placed on the
indicated ballast foundations. In
three steps
you can easily calculate the required ballast;
• determine the wind area on the windmap
• choose the wind area and building height in the table
• you can now read the number of tiles / kg
Note 1:
The extra ballast must be equally divided over the ballast foundations.
Note 2:
The max. of 32 tiles can be placed for extra ballast (288 kg).
Building height
0 - 5
meter
5 - 7
meter
7 - 9
meter
9 - 12
meter
12 - 15
meter
23 m/s
11,0
45,0
71,0
103,0
128,0
kg
1,5
5,0
8,0
11,5
14,5
tiles
24 m/s
30,0
67,0
96,0
130,0
158,0
kg
3,5
7,5
11,0
14,5
18,0
tiles
25 m/s
50,0
90,0
121,0
158,0
188,0
kg
6,0
10,0
13,5
18,0
21,0
tiles
26 m/s
70,0
113,0
147,0
188,0
220,0
kg
8,0
13,0
16,5
21,0
24,5
tiles
Building height
0 - 5
meter
5 - 7
meter
7 - 9
meter
9 - 12
meter
12 - 15
meter
23 m/s
38,0
77,0
108,0
145,0
174,0
kg
4,5
9,0
12,0
16,5
19,5
tiles
24 m/s
60,0
103,0
136,0
176,0
209,0
kg
7,0
11,5
15,5
20,0
23,5
tiles
25 m/s
83,0
129,0
166,0
209,0
244,0
kg
9,5
14,5
18,5
23,5
27,5
tiles
26 m/s
106,0
157,0
196,0
244,0
281,0
kg
12,0
17,5
22,0
27,5
31,5
tiles
Environmental factors
Position
Middle zone roof
Terrain category
III (villages, suburban terrain, permanent forest)
Roofing materials
Bitumen
X
= the required ballast is higher than will fit under the system. The system must be mechanically attached to the roof. Please contact Van der Valk Solar Systems.
* If you use tiles of different sizes and thus another weight, you need to adjust the number of tiles to get the right weight.
Ballast foundations
Содержание ValkTriple
Страница 1: ...Installation manual ValkTriple Version 01 December 2021...
Страница 28: ...09 Mount cable clamp on the panel...