Electrical connection of the three position switch
Attention; this pre-mounted three position switch (28) with maximum current protector (29) is
optional.
make sure the main switch is turned off and locked;
make sure all electrical connections are free of any charge;
put the power cable through the transit swivel (27);
connect the earth cable to the earth connection terminal (31);
connect the three phases to the connections L1, L2 and L3 (32);
if these connections have different names; contact manufacturer;
check whether the maximum current protector (29) is set to the correct value;
o
the little wheel (30) must indicate the maximum value, which can be found on the
motor type plate, as mentioned at the delta connection (
);
check the direction of rotation after start-up;
o
the correct direction of rotation is indicated with an arrow on the cooling fan cap;
change if necessary two phases at connection 32 in order to change the direction of rotation.