6) If any set(s) of wire are short,
only the shorted pair of wires
will be shown. For example, if
the display is shown as right,
it means that line 1 and 2 are
short.
7) If more than one pair of wires are shorted, the meter will the
shorted pair one by one.
8) After testing, switch off the Main Body by holding down
the button for 3 seconds.
For connecting to the
LOOPBACK
and the
RJ45
jack on the receiver,
1) Unplug all the cable(s) connected to the main body and receiver;
2) Plug one side of the testing cable to the
LOOPBACK
jack on
the Main Body and the other side to the
RJ45
on the receiver;
3) The upper part of the secondary display will move from 1 to 8, and
the corresponding LED on the receiver will also be switched on;
4) If the connection is correct, the number showing on the Main Body
will be matched with the LED on the receiver;
5) Otherwise, the connection is incorrect.
6) After tracing, switch off the Main Body by holding down
the button for 3 seconds;
7) There is no need to switch off the receiver.
a
Uto
p
oWeR
o
ff
The equipment will automatically switch off if there is no function or button
press for 30 minutes.