background image

7

8

   

Caution:

a. 
    previous operation, then press “CHARGE” key, the previous screen will appear.
b. If you want to finish earlier during charge mode, press “CLEAR” key to stop.

If you press a wrong key during charge mode, press “ENTER” key to cancel the

5.6 RECOVER MODE

   
with a recovery/recycle machine component of a system.

 The scale is not only a stand-alone scale but also can be compared

1. Make sure all connections are correct and tight (refer to following
    illustration):

2. Turn the scale on.
3. Place refrigerant tank on scale. Wait for the reading to settle out.
    e.g. The refrigerant tank is 12 Kg, the following screen will appear:

VES-50B/100B

VES-50B/100B

Kg

Kg

Kg

6. If the scale is not connected to the AC power, the solenoid valve will
    not work. The scale’s buzzer will alarm when charging nearly finish

    (refrigerant 

0.05 Kg). when the charge is completed, stop the charge

    system manually. Press the “Enter” key exit to screen, the scale will
    display the gross weight of refrigerant tank.

2. Turn the scale on.
3. Place refrigerant tank on scale. Wait for the reading to settle out.
    e.g. The refrigerant tank is 12 Kg, the following screen will appear:

4. Press “Charge” key, the Charging Indicator will appear, and enter the

    

weight to be charged, then press “Enter” key. The solenoid valve will

    

open and the refrigerant will start to transfer.

    

e.g. The weight to be charged is 1

 

K

g, press “Charge”

“1”

 

“Enter”

  

step by step.

5. When the entered amount of refrigerant has been transferred, the
    solenoid valve will shut off automatically and the scale will display
    the gross weight of refrigerant tank.

Power Supply

Air-conditioning

System

RECOVERYSYSTEM

Tank

Отзывы: