VALTRONICS 2011 Скачать руководство пользователя страница 4

 
 

Copyright 2011 VTI-Valtronics Inc. 

 

 

 

                                                  
 
                                                  

Features 

   

               NDIR Technology 
               Triple displays of CO

2

, temperature, and humidity.  

               Statistics of weighted averages. 
                         TWA (8 hours of weighted averages) 
                         STEL (15 minutes weighted averages) 
               Audible 

CO

warning alarm 

               Backlight on display 
               Easy manual calibration for 

CO

and humidity 

               PC connector via RS232 interface 

 

 
 
 
 
 
 
 
 
 

Applications

  

 
 

  Indoor air quality 

  Wineries and breweries 

 Greenhouses 

 Food 

processing 

 Detection 

of 

CO

for NFPA 12 regulations 

 

CO

2

 storage facilities 

 
 
 
 
 
 
 
 

Содержание 2011

Страница 1: ...VALTRONICS IAQ Monitor Model 2011 Instruction Manual 990116...

Страница 2: ...eatures 3 Applications 3 Display 4 Key Pad 5 OPERATION 6 Power Operation 6 Measurements 6 Data Hold 6 Backlight 6 STEL TWA MIN and MAX 6 Alarm 6 Auto Power Off 7 Set up 7 CO2 Alarm 7 Temperature Scale...

Страница 3: ...outstanding reliability and long term stability The unit is powered by four AA batteries or a DC adapter When the DC Adapter is used it cuts off the batteries The Adapter can not be used as a battery...

Страница 4: ...TWA 8 hours of weighted averages STEL 15 minutes weighted averages Audible CO2 warning alarm Backlight on display Easy manual calibration for CO2 and humidity PC connector via RS232 interface Applica...

Страница 5: ...8 hours STEL Short term exposure limit 15 minutes weighted average HOLD Readings are frozen unchanged MIN MAX Minimum maximum readings Low battery indicator DP Dew point temperature Air Air temperatu...

Страница 6: ...nters CO2 calibration with MODE Enters RH calibration with DP WBT Freezes the current readings Cancels data hold function Activates or cancels the backlight Selects unit or increases value in set up S...

Страница 7: ...the HOLD button will freeze all readings except the STEL and TWA Pressing the HOLD button again will cancel the hold mode Backlight Pressing and holding the MODE button for more than 1 second will ac...

Страница 8: ...et the CO2 alarm note the CO2 display will be blinking at the current alarm level Each press of the MODE button will increase the value by 100 ppm Pressing the DP WBT will decrease the alarm value The...

Страница 9: ...it indicates 400ppm 25ppm it is not necessary to go any further The accuracy is ok and it is not necessary to go through the entire calibration process If the reading is out of specification press and...

Страница 10: ...Resolution 0 1 Rh Accuracy 3 from 10 to 90 Warm up time 30 seconds Operating temperature 0 to 50 C Storage temperature 20 to 60 C Humidity 0 to 95 Rh non condensing Power AA batteries 4X Battery life...

Страница 11: ...pering of internal electronics RETURN POLICY Valtronics will honor warranty repairs within one year of purchase and will make every attempt to repair non warranty damage defects or functional failures...

Страница 12: ...Copyright 2011 VTI Valtronics Inc 11 Notes For ordering information contact Valtronics Sales Department Phone 209 754 0707 FAX 209 754 0104 e mail vti val tronics com www val tronics com...

Страница 13: ...Copyright 2011 VTI Valtronics Inc 12 Notes For ordering information contact Valtronics Sales Department Phone 209 754 0707 FAX 209 754 0104 e mail vti val tronics com www val tronics com...

Отзывы: