Minimum Wire Size for a 10% voltage drop on a 12VDC, 10Amp Circuit. Length is the distance 

from the power source to pump and back to ground. 

·

The total current draw on the circuit must not exceed 15 amps. If the pump is used in conjunction 

with other components, overload current protection (fuse or circuit breaker) and wire size must be 

for the total amp requirements of all devices on the circuit. 

Feet              [Meters] 

AWG              [mm 2 ] 

0-25              [0-7.6] 

 

14                    [2.1]  

25-50      [7.6-15.2]   

12          [3.3]  

50-70      [15.2-21.3]  

10          [5.3]  

70-110     [21.3-33.5]  

 8          [8.4]  

 

PLUMBING 

HYDROMAX recommends at least 1ft[.3m]of 1/2"[13mm]I.D. flexible high pressure tubing to 

both ports. Ideally the pump's ports/strainer should not be connected to plastic or rigid pipe. The 

pump's normal oscillation may transmit through rigid plumbing causing noise, and possibly loosen 

or crack components. 

Installation of a 50 mesh strainer such as the HYDROMAX P25206VP is recommended to 

prevent foreign debris from entering the pump. HYDROMAX P25205VP is a hex/swivel barb 

fittings that provides easy removal if maintenance or access is required. The fittings are designed 

with a "taper-seal", creating a water tight connection when hand-tightened. Always secure barb 

tubing connections with properly sized stainless steel clamps to prevent leaks. Never use Teflon 

tape or sealing compounds on threads. Sealer may enter the pumps causing a failure. Failure due 

to foreign debris is not covered under warranty. 

 

Rapid cycling may be caused by excessive back pressure created by one or more of the following 

within a plumbing system: Water filters and purifiers not on separate feed lines, Flow restrictors in 

faucets and shower heads, Small ID lines Pipe/tubing should be at least 1/2”(13mm) for main lines, 

Restrictive fittings and connections (elbows, “T” s, feeder lines to faucets, etc).    The pump with 

by-pass do not need to use pressure tank. 

If the pump is cycling rapidly increase the setting by turning the screw clockwise (1 1/2 turn 

MAX.) until the pump operates for 1 sec. with at least 2 sec.” OFF time”. 

 

The pump's duty cycle is: intermittently. Do not use the pump under anti-osmosis filtering system. 

Continuous running under higher pressure may reduce pump life and it is not under the warranty. 

 

Operation

only for HYDROMAX Automatic Fresh Water Pumps-42series) 

This pump is designed for intermittent duty only. 

The pump operates normally up to about 40-psi, where a spring-loaded by-pass valve opens, 

allowing flow back from the output side to the input side, providing smooth, steady flow with 

virtually no cycling, all the way down to a trickle. As a faucet is opened back up, the pressure will 

drop, the by-pass will close and full flow is again obtained. This allows good flow, even with 

today's restrictive showers and pullout sprayer faucets. Performance will vary, of course, 

depending on the voltage to the pump; lower voltage=lower flow, higher voltage=higher flow. 

Remember your electrical safety: It is always best to shut off power to the pump OFF when 

Содержание HydroMax P25201

Страница 1: ...to prevent incidental moisture from entering and when installed correctly RV Marine Duty Fresh Water Pumps provide years of quiet operation A HYDROMAX pump in combination with a low backpressure water...

Страница 2: ...e mounted in any position If mounting the pump vertically The pump head should be in the down position The mounting feet are intended to isolate the pump from the mounting surface over tightening flat...

Страница 3: ...causing a failure Failure due to foreign debris is not covered under warranty Rapid cycling may be caused by excessive back pressure created by one or more of the following within a plumbing system Wa...

Страница 4: ...enance to deliver a consistent flow of fresh water Depending on use and the environment the system is subject to sanitizing is recommended prior to storing and before using the water system after a pe...

Страница 5: ...ong with other particulars of your system PUMP WILL NOT START BLOWS CIRCUIT Is the motor hot Thermal breaker may have triggered it will reset when cool Electrical connections fuse or breaker main swit...

Страница 6: ...th pump head removed Is noise from motor or pump head RAPID CYCLING Pressure switch shut off adjustment Water filter purifier should be on separate feed line For restrictive plumbing flow restrictors...

Страница 7: ...ROMAX will not warrant any pump that is physically damaged or altered outside the HYDROMAX factory Warranty claims may be resolved by an authorized dealer service center or by a HYDROMAX service cente...

Отзывы: