Valterra HydroMax P25201 Скачать руководство пользователя страница 1

Valterra Products, LLC    Mission Hills, CA 91346   1-800-806-6159   www.valterra.com 

P25201 HydroMax Automatic Fresh Water Pump 

RV/MARINE 

INSTALLATION AND OPERATION MANUAL 

 

HYDROMAX design delivers smooth

consistent flow at all ranges of operation, while drawing 

low current. The balanced motor design incorporates precision ball bearings for long life, and is 

equipped with an integrated thermal breaker. All RV/marine duty pumps have sealed switches and 

are finished with a Electro Coating to inhibit corrosion. HYDROMAX water pumps have been 

strictly inspected and can run smoothly. RV/Marine duty fresh water pumps are enclosed to 

prevent incidental moisture from entering and when installed correctly, RV/Marine Duty Fresh 

Water Pumps provide years of quiet operation. A HYDROMAX pump in combination with a low 

backpressure water system can exceed all expectations. All HYDROMAX pumps are CE certified. 

 

GENERAL INFORMATION 

HYDROMAX realizes that in many instances our pump is being installed as a replacement pump 

within an existing system. The following guides should be considered to achieve optimum pump 

operation. Always follow all local or national installation codes & standards. 

 

Installation instructions: ( RV ) 

·

Solid surface. 

·

Accessible location away from living quarters. 

·

Properly sized wiring. 

·

Proper electrical protection. 

·

Flexible hose on inlet and outlet. 

·

Strainer on plumbing elbows and valves near the pump. 

·

Minimize flow restrictions in the system. 

 

 

Содержание HydroMax P25201

Страница 1: ...to prevent incidental moisture from entering and when installed correctly RV Marine Duty Fresh Water Pumps provide years of quiet operation A HYDROMAX pump in combination with a low backpressure water...

Страница 2: ...e mounted in any position If mounting the pump vertically The pump head should be in the down position The mounting feet are intended to isolate the pump from the mounting surface over tightening flat...

Страница 3: ...causing a failure Failure due to foreign debris is not covered under warranty Rapid cycling may be caused by excessive back pressure created by one or more of the following within a plumbing system Wa...

Страница 4: ...enance to deliver a consistent flow of fresh water Depending on use and the environment the system is subject to sanitizing is recommended prior to storing and before using the water system after a pe...

Страница 5: ...ong with other particulars of your system PUMP WILL NOT START BLOWS CIRCUIT Is the motor hot Thermal breaker may have triggered it will reset when cool Electrical connections fuse or breaker main swit...

Страница 6: ...th pump head removed Is noise from motor or pump head RAPID CYCLING Pressure switch shut off adjustment Water filter purifier should be on separate feed line For restrictive plumbing flow restrictors...

Страница 7: ...ROMAX will not warrant any pump that is physically damaged or altered outside the HYDROMAX factory Warranty claims may be resolved by an authorized dealer service center or by a HYDROMAX service cente...

Отзывы: