INSTALLATION AND MAINTENANCE INSTRUCTIONS 

HIGH PURITY BALL VALVES 

M3HP TRUE BORE 

 
 
GENERAL 
 

  These instructions must be carefully read before any work involving products supplied by VALSTEAM ADCA 

ENGINEERING S.A. is undertaken. 

 

  The installation procedure is a critical stage in a life of a valve and care should be taken to avoid damage to the 

valve or equipment. 

 

  They  give  their  maximum  performance  only  when  the  equipment  associated  with  them  is  correctly  sized  and 

installed in accordance with our recommendations. 
 

  M3HP  three  pieces  body  ball  valves  are  isolating  valves  designed  for  use  on  clean  steam,  condensate  and 

other gases and liquids used in high purity and aseptic processes. The valve is not designed as a control valve 
and should be used only as an isolating valve, fully open or fully closed. 
 

  The  product  was  mainly  designed  for  the  pharmaceutical,  biotech,  semiconductor,  cosmetics,  fine  chemical, 

food and beverage industries. 

 
 
Note: 
 

  Current regional safety regulations should be take in to account and followed, while doing the installation and 

maintenance work. 

  Handling, installation and maintenance work must be carried out by trained personnel. A supervisor must follow 

and check all activities. 

  For the problems that cannot be solve with the help of this instructions, please contact the supplier or the 

manufacturer. 

  The manufacturer reserves the right to change the design and material of this product without notice. 

 

 
CE Marking: 

This product has been designed for use on water, clean steam and other liquids or gases which are in 

Group  1  and  2  of  the  PED-European  Pressure  Equipment  Directive      97/23/EC  and  it  complies  with  those 
requirements.  
 

PN 100

PN 64

Category

DN 1/2" to 1"

/

SEP - art. 3, paragraph3

/

DN 11/2" -2"

1 (CE Marked)

CE MARKING (PED - European Directive 97/23/EC)

 

 

 

 

 

If malfunction of any other equipment or system operation failure may result in a dangerous overpressure, over 
temperature or even vacuum condition, a safety device must be included in the system to prevent such 
situations. 

At start up, the presence of small particles in the fluid (dirt, scale, weld splatters, etc) may cause an imperfect 
closure of the seat. If this occurs, proceed to an accurate cleaning. 

Do  not  touch  the  equipment  without  appropriate  protection  during  working  operation  because  it  may  conduct 
heat if the used fluid is at high temperature. 

Before starting maintenance be sure that the equipment is not pressurized or hot. 

Содержание M3HP

Страница 1: ...tallation and maintenance work must be carried out by trained personnel A supervisor must follow and check all activities For the problems that cannot be solve with the help of this instructions pleas...

Страница 2: ...contractor Valves are designed to be applied in places protected from exposure to weather CLEANING AND PACKING This equipment is packed by a proper machine with a special film used by food industry Th...

Страница 3: ...o weight especially in bigger valves In those cases follow these steps 1 Remove the bolts to separate the valve body from the body connectors 2 Carefully remove the body seals and put them on a clean...

Страница 4: ...tions if necessary MAINTENANCE We recommend the ball valves to be serviced as necessary Ball valves should be checked periodically at least yearly to verify if they are operating correctly if they hav...

Страница 5: ...pression nut 15 4 Remove the belleville spring washers 14 and the spacer 11 5 Remove the stem seals 10 6 Carefully push the stem 5 into the body to remove it 7 Replace all the stem seals and the o rin...

Страница 6: ...Damaged stem seals Remove the lever 12 13 the lock washer 16 and inspect If the spring washers 14 are in good conditions but loosen retighten the compression nut 15 if the spring washers are damaged...

Страница 7: ...vice AISI316 1 4401 21 O ring VITON Remarks FDA USP Class VI seals certificate on request All valves have a serial number In case of non standard valves this number must be supplied if spare parts are...

Отзывы: