background image

  

 

VAL

S

TEAM

 

ADCA

                       

  

 

We reserve the right to change the design and material of this product without notice.

 

 

 

 

        IMI 1.381 E 05.14

 

 

 
 
Excessive back pressure. 
 
 
Damaged float. 
 

 
 
Replace the steam trap by a 
superior DN or use ADCAMAT. 
 
Replace. 

 
Temporary condensate 
accumulation 
 

Steam blocking. 
 
Downsizing. 

 
Use a steam trap with SLR. 
 
Check maximum flow rate (during 
start-up) 

Slow initial start up 

 
Damaged air eliminator. 
 
The air flow is too high for the trap. 
 
Downsizing. 

 
Replace. 
 
Install an additional air eliminator. 
 
Check maximum flow rate (during 
start-up) 

 
 

PARTS LIST FOR FLT32- 

STEAM TRAPS DN 1/2”- 1”, DN15-DN25 

TRAP SIZE

DN

A.92.2402.015 Valve,seat,float&gasket D.P.4,5bar

DN1/2”-1” 

3,4,5,6,7

1Set

A.92.2403.015 Valve,seat,float&gasket D.P.10 bar

DN1/2”-1” 

3,4,5,6,7

1Set

A.92.2404.015 Valve,seat,float&gasket D.P.14 bar

DN1/2”-1” 

3,4,5,6,7

1Set

A.92.2405.015

Valve,seat,float&gasket D.P.21 bar

DN1/2”-1” 

3,4,5,6,7

1Set

A.92.2402.115  Float & gasket

DN1/2”-1” 

3,7

1Set

A.92.2402.215

Air vent & gasket

DN1/2”-1” 

3,7

1Set

CODE

DESIGNATION

QTY.

POS.NR.

 

 

Recommended tightening torques FLT32 DN 1/2”-1”, DN15-DN25 

TRAP SIZE

DN

4

1/2

”-1” 

50±5

8

1/2

”-1” 

50±5

9

1/2

”-1” 

70±5

POS.NR.

Nm

 

Remarks: Tighten cover bolts uniformly. 

 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 