IMI 1.381 E 05.14
Excessive back pressure.
Damaged float.
Replace the steam trap by a
superior DN or use ADCAMAT.
Replace.
Temporary condensate
accumulation
Steam blocking.
Downsizing.
Use a steam trap with SLR.
Check maximum flow rate (during
start-up)
Slow initial start up
Damaged air eliminator.
The air flow is too high for the trap.
Downsizing.
Replace.
Install an additional air eliminator.
Check maximum flow rate (during
start-up)