17
EN
7. Operating instructions
LED operations and acoustic alarms
The machine is equipped with acoustic alarms and light signals.
The green LED indicates the status of the operation.
The red LED indicates the status of the potential errors.
The keyboard controls the operations
7.1 Prepare the pipes and the fitting to be welded according to the reccomendations
given in the "General Welding Criteria" chapter and the instructions of the pipe and
fitting manufacturers.
7.2 Connect the power supply plug to the mains: the green LED will flash slowly.
7.3 Connect the welding terminals to the fitting and press START. The green LED will flashes
quickly to warn that the machine is ready to weld. If the welding does not start in 10
seconds, the machine returns back to stand-by state (slow flashing).
7.4 Press START again: the machine starts welding. The green LED will stay on till the
welding ends.
7.5 Both LEDs flash at the end of welding. Press STOP to return back to the to stand-by
status.
Summary
Operation
Green LED
Red LED
Acoustic alarm
Status
Electric
connection
Flashing
1 beep
Power supply is
recognized
Terminals
connected to the
fitting. Press START
Flashing quickly
for 10 seconds
1 beep
Fitting connection
recognized.
Ready to weld
Press START
Always on
1 beep
Welding
Welding ended
Flashing
Flashing
Intermittent beeps
Welding ended
Press STOP
Flashing
1 beep
Stand by
If the fitting is non-compliant or is faulty, it is not possible to weld.
Press the STOP button and repeat the operation with another fitting.
Welding is not possible when the ambient temperature detected by the thermal probe
does not conform to the range indicated in the technical characteristics.
LEDs