Electrical Recommendations
ELECTRICAL CONNECTION PROCEDURE
Wieland mains input connector connection
Connect your incoming mains cable to the Wieland RST female connector (ZHPF8144) as shown below.
Live
Neutral
Earth
Incoming cable
Incoming cable
1
2
3
Phoenix in-line connector connection (for dimming)
Connect suitable 2-core cable to the in-line Phoenix connector as shown below (
note:
images show 3-core cable, but an
earth is not required for the dimming connection). Connect pins 1 (+) and 2 (-) only.
See also: https://bit.ly/2sZKg5B
1
2
3
4
Remove mating part & discard blanking end cap
Insert your cable (2-core)
Connect: Pin 1 (d)
Pin 2 (dimming -)
Trim excess wire
5