Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. 
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust 
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-
circulated back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct 
work, if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option 
is not possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal fi lters are required on top of its standard 
Aluminum Mesh Filter set. Order according to its part number below. The standard Aluminum Mesh Filters are 
intended to capture residue from cooking and the optional charcoal fi lters help to purify fumes exhausted from 
cooking for re-circulation.

RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)

Kit includes charcoal fi lters, charcoal fi lter brackets and air diverter plate.

Hood Models 

    Part No. 

          Filters & Brackets in pkg.                         

VLA 

    VRC-00LA   

 

         2 

1.   Purchase recirculating kit per the part number above

2.   Secure air diverter plate to wall below duct cover bracket. (FIG. C) Run 

6” ducting from top of hood and secure to air diverter plate.

3.  Remove aluminum mesh fi lters from hood. Install charcoal fi lter 

brackets inside fi lter opening. Note: screws to secure charcoal fi lter 
brackets are already pre-installed in the hood and must fi rst be 
removed. Clip charcoal fi lters onto charcoal fi lter brackets. (FIG. C)

4.   Re-Install  aluminum mesh fi lters. 

For more details refer to manual 

included with recirculating kit.

5.  Charcoal fi lters must be replaced after every 120 hours of use (or 

approximately every 3 to 4 months based on an average of 1 - 2 hrs. of 
daily cooking time).

Charcoal Filter Replacements

Hood Model 

 

Part No. 

          Qty to Order

VLA 

 

V0F-C002   

   1

DO NOT WASH CHARCOAL FILTERS.  Charcoal fi lters may need
to be changed more often depending on cooking habits.

Installation – 

Ductless Recirculating

FIG. C

Содержание VLA-E30AS

Страница 1: ...Use Care and Installation Guide Model number Serial Number Lateral Wall VLA E30AS VLA E36AS JUN11 0101...

Страница 2: ......

Страница 3: ...Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Electronic Controls 11 MAINTENANCE Hood and Filter Cleaning 12 Light Bulbs 13...

Страница 4: ...of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or me...

Страница 5: ...is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes...

Страница 6: ...s Extension duct cover accessory V1C 00LA Recirculating kit accessory VRC 00LA HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS VLA E30AS VLA E36AS 1 Hood with internal blower 1 Duct cove...

Страница 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Страница 8: ...performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differe...

Страница 9: ...e unless using the recirculating option Use single wall rigid metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting O...

Страница 10: ...od Specifi cation 6 CL 29 15 16 35 7 16 14 1 8 2 13 16 20 1 16 STANDARD min ducted 26 min recirc 31 max 53 V1C 00LA EXTENSION min ducted 42 min recirc 46 max 80 11 7 1 16 9 7 16 10 9 16 2 3 16 3 9 16...

Страница 11: ...just below the ceiling or soffit using 2 M6 x 1 screws FIG A 3 10 Install duct work and seal with aluminum duct tape Re install junction box with cable lock and install the electrical FIG B 2 11 Power...

Страница 12: ...usted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filters charcoal filter brackets and air diverter plate Hood Models Part No Filters Bracket...

Страница 13: ...Blower Speed Selection 2 Delay Off Timer 4 Blower On Off Press to turn blower on and off If lights are on they will also switch off when this button is pressed Press to cycle through light levels Brig...

Страница 14: ...otton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to fil...

Страница 15: ...by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach the included glass suction cup or...

Страница 16: ...e defective part The unit is vibrating 1 The motor is not secured in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the insta...

Страница 17: ...15 Wiring Diagrams...

Страница 18: ...ght Bulb GU 10 50W each Z0B 0020 Optional Accessories Recirculating Kit VRC 00LA Replacement Charcoal Filters Qty 2 V0F C002 Extension Duct Cover V1C 00LA Order replacement parts from us by calling 1...

Страница 19: ...labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE F...

Отзывы: