4008057-05

Hot glass 

will cause burns.
Do not touch glass 

until cooled.
Never allow children 

to touch glass.

A barrier designed to reduce 

the risk of burns from the hot 

viewing glass is provided with this 

appliance and must be installed for 

the protection of children and 

other at-risk individuals.

DANGER

WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings 

exactly could result in serious 

injury, death, or property damage.

Do not store or use gasoline or other 

fl

 ammable vapors and liquids in the 

vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do 

not use any phone in your building.

Leave the building immediately.

Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 

supplier’s instructions.

If you cannot reach your gas supplier, 

call the 

fi

 re department.

Installation and service must be 

performed by a quali

fi

 ed installer, service 

agency or the gas supplier.

Direct Vent Zero Clearance

Gas Fireplace

natural gas    1800KN

propane gas   1800KP

Installation Manual

L3

Installer: Leave this manual with the appliance.

Consumer: Retain this manual for future reference.

Installer: Place model/serial number here.

Содержание L3 1800KN

Страница 1: ...iquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and se...

Страница 2: ...ts reserved Designed and manufactured for Miles Industries Ltd Valor Fireplaces 190 2255 Dollarton Highway North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appliance may be installed in an after market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating p...

Страница 3: ...ermination 23 Vertical Vent Termination 24 Installation 25 Appliance Preparation 25 Unpack Appliance 25 Fit Standoffs 25 Fit Appliance into Framing 25 Remove Window 26 HeatShift System if used 27 Remove Convection Baffle 27 Install HeatShift Take Off Collars to Appliance 27 Electrical Wiring 28 Gas Supply 30 Liners 32 Fuel Beds 34 Driftwood Log Kit 1800DWKV2 34 Decorative Glass Murano Kit 1800DGMV...

Страница 4: ...3 C depending on elevation of hearth Be careful of touching these Tem perature of projection surfaces will be reduced when barrier screens are installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other combustible objects sensitive to heat or furniture within 36 inches ...

Страница 5: ...ing a separate solid fuel burning ap pliance Each gas appliance must use a separate vent system Common vent systems are prohibited WARNING Do not operate this appliance with the glass front removed cracked or broken Replacement of the glass front should be performed by a licensed or qualified service person Do not strike or slam the glass front Intended use This appliance is designed and approved ...

Страница 6: ...eft hand side of the firebox A shut off valve not supplied is required on the supply line to isolate the unit during service See Gas Supply Installation section for details Conversion Kits The 1800K are supplied as natural gas or propane gas and are field convertible between fuels See instructions packaged with the conversion kits for further information Electrical The 1800K are designed to run on ...

Страница 7: ...0PBL Plain Black Liners Trims choose one Barrier Screen 1830CIK Clean Install Kit Fine Mesh REQUIRES HeatShift 4007940 1850LSB Linear 3 1 2 Surrounds 4005460 1875LFB Linear 1 Finishing Trim Black 4005413 Gas Conversion Kits 1800KNGK Conversion to natural gas 1800KPGK Conversion to propane gas Other Accessories GV60WIFI WiFi kits REQUIRES GV60VM Kit GV60CKO Outdoor Fireplace Conversion Kit 1506DRK ...

Страница 8: ...l Outlet DO NOT CONVERT TO HORIZONTAL OUTLET 72 18 15 1 16 15 1 16 15 1 1 18 5 8 3 3 4 20 32 3 8 9 3 8 14 1 2 66 1 4 64 LDK HeatShift Duct Kit outlets remove plates E ectrical le et Inle int Po 3 2 2 1 16 8 5 8 4 Zero Clearance to Stand offs at Back and Sides Zero Clearance at back corners 1 0 2 1 4 2 5 9 7 m m 72 1 4 1835 mm 20 1 2 519 mm Zero Clearance at back corners Face of Framing Top View Di...

Страница 9: ... Con tent sheet Also check that you have Fuel bed packed separately Liner panels packed separately Remote Battery and Wall Switch Kit HeatShift System components if used Gas conversion kit if necessary Venting accessories Electrical accessories if used 4 Carefully read the Installer s Checklist included with the fireplace for the installation sequence Caution Only qualified licensed or trained per...

Страница 10: ...mperatures in excess of 200 F 93 C depending on choice of trims Do not touch Finish wall using materials suitable for these temperatures Framing See Framing Requirements Mantel See Mantel Hearth Clearances 1 2 inch thick non combustible cement board NOT supplied Supplied as vertical outlet SHOULD NOT be field converted to horizontal outlet Note Minimum 24 vertical rise required right at appliance ...

Страница 11: ...t Fireplace Opening Ceiling 36 Min to Ceiling 54 52 50 48 23 7 8 9 3 8 4 minimum to combustible or non combustible hearth Combustible Mantel Left Side View Installation Planning Mantel Clearances NOTE Use for the optional HeatShift System affects mantel and hearth clearances See HeatShift section in Appendix D of this manual WARNING HeatShift System MUST be installed on this appliance when using 1...

Страница 12: ...12 Combustible Sidewall Mantel Leg Top View Installation Planning Mantel Clearances 64 1626 mm Fireplace Opening Wall Min 4 102 mm to wall or combustible mantel leg Face of Finished Wall FIREPLACE ...

Страница 13: ...ide and below engine opening NOT supplied NOTE Height of cavity may be affected by vent configuration see page 26 Between underside of header and bottom of firebox No hearth required If using a hearth see page 22 NOTE This unit requires a solid platform to support it Combustible framing allowed beneath fireplace When the appliance is installed directly on carpeting tile or other combustible materi...

Страница 14: ...vity Min 1 25 4 mm clearance to combustibles around vertical vent pipe Approx 10 3 4 274 mm from back surface of wall finish to front surface of appliance case w no vent offset 15 3 16 386 mm 14 1 2 369 mm 9 3 8 238 mm 24 1 8 613 mm Fireplace Opening PARTIAL SHELF top outlet 1 2 thick non combustible Cement Board ...

Страница 15: ...Vent elbows Elbow curve radius dimensions will vary when using other brands In general other brands have slightly bigger radius Minimum 24 inches vertical pipe section required right at unit Refer to venting chart on page 30 for allowable horizontal runs 3 inches clearance to combustibles required above horizontal pipe Slope horizontal pipe upwards 1 4 inch per foot 1 inch clearance required aroun...

Страница 16: ...terials in a Vertical Tube Furnace at 750 C shall be considered non combustible materials Combustible Materials made of or surfaced with wood compressed paper plant fibers plastics or other material that can ignite and burn whether flame proofed or not or plastered or unplastered shall be considered combustible materials Non Combustible Cement Board The L3 Linear fireplace requires a 1 2 13 mm thi...

Страница 17: ... Over Cement Board Additional non combustible material such as tile etc may be applied over top of the cement board or you may choose to leave it finished clean with no tile etc Be aware that a trim is always required Finish should not cover the trims 1875 and 1850 Trims Only the 1875 and 1850 style trims will accept tile etc tucked behind them up to 5 8 thick for the 1875 and up to 1 inch thick f...

Страница 18: ... HeatShift System MUST be installed on this appliance when using 1830CIK Clean Installation Kit Always pre drill screw holes through cement board and use screws specific for material used Always use mesh tape over joints Always stagger joints in wall board Behind joints double up studs or use studs on the flat to add extra support to the joint Adhesive on the backside of wall board behind any join...

Страница 19: ...run of vent pipe allowed for the particular installation Framing Vent in Combustible Walls Ceilings When penetrating through combustible walls and ceilings frame a minimum of 10 in x 10 in opening and ensure that the insulation is kept clear of the vent pipe using either a wall thimble or an attic insulation shield Follow the installation instructions supplied with the individual venting component...

Страница 20: ... PIECE WALL THIMBLE PIPE LENGTH PIPE LENGTH PIPE LENGTH PIPE LENGTH CEILING FIRESTOP ATTIC FIRESTOP ATTIC INSULATION SHIELD FLASHING STORM COLLAR VERTICAL TERMINATION 90 ELBOW Typical Co axial Venting Components Venting Co Axial ...

Страница 21: ...the appliance 6 Each 90 degrees elbow installed on the horizontal plane is equivalent to a 3 feet horizontal pipe therefore 3 feet must be subtracted from allowable horizontal run 45 degrees elbow is equivalent to 18 inches horizontal pipe 7 All horizontal pipe runs must be graded 1 4 inch per foot upwards in the direction of the exhaust flow The final pipe length when terminating through the wall...

Страница 22: ...r venting with no vertical rise The level of restriction required depends on the vertical rise in the venting system and to a lesser degree the horizontal run and number of elbows The amount of restriction is based on laboratory tests The ideal restrictor position may vary slightly especially when the vent pipe length is near the limits of the acceptable configurations for each type of restrictor ...

Страница 23: ... regulator assembly located within 15 feet 4 6bm below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the building or the combustion air inlet to any other appliance 12 30 K Clearance to a mechanical air supply inlet 72 180 L Clearance above paved sidewalk or a paved driveway located on public property Note A vent must not te...

Страница 24: ... Vertical wall Min 24 unvented soffit Min 36 vented soffit Termination cap Min 18 Storm collar Roof flashing H Vertical Vent Termination Roof Pitch Minimum H feet Flat to 7 12 1 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 Over 12 12 to 14 12 5 ...

Страница 25: ...ack Appliance Beware of sharp edges Wear gloves 1 Remove the cardboard wrapping and the wood pal let from the appliance and discard 2 Unpack any loose items from around the appliance 3 Remove the window and set aside in a safe place to avoid damage see Remove Window on page 26 4 Verify that you have all the components re quired for the installation including approved cement board liners and fuel b...

Страница 26: ...ve the window locate the levers on each side of the window towards the top Using your fin ger pull the lever towards you and unhook it from the window frame bracket 2 Gently pull the top of the window outward 3 Lift the window out of its bottom railing and set it aside in a safe place to avoid damage Installation Appliance Preparation ...

Страница 27: ...e appliance It is held in place by 3 screws located right behind the upper edge of the fireplace opening Recycle this panel as it is no longer needed Remove convection baffle Appliance front panel shown transparent for clarity Convection baffle Install HeatShift Take Off Collars to Appliance 1 Remove the four cover plates on top of the appli ance case 6 screws each 2 Install the take off collars on th...

Страница 28: ...prong grounded plug to plug into a grounded receptacle installed within the fireplace en closure by a qualified electrician The receptacle housing and strain relief are supplied and installed as part of the fireplace Notes We recommend connecting the electrical box even if the optional accessories have not been purchased It is much easier to wire before wall finish is applied Wiring within the rec...

Страница 29: ...ate grounded receptacle using wire nuts not included Place the connected receptacle back in the fireplace and pull excess cable back through the strain relief 6 Place the inner cover and receptacle in position and replace 2 screws 7 Leave your desired cable slack in the electrical box and tighten the strain relief cable clamp outside of fireplace casing and secure and excess wire to framing Instal...

Страница 30: ...onstituents including LP gas Sealant should be applied lightly to male threads to ensure excess sealant does not enter gas lines 3 3 4 95 mm Gas line access hole 2 1 2 64 mm diam 4 102mm Front of the appliance Left side view Installation Gas Supply X Replace the Bypass Screw if using 1800SWK Splitwood Kit ONLY You can access the bypass screw on the valve through the hole in the lower front panel o...

Страница 31: ...alight and at its highest setting See Appendix A Lighting Instructions on page 58 for full operating details Installation Gas Supply Caution Never use an open flame to check for leaks Correct any leak detected immediately Pressure test the supply line for leaks The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that ...

Страница 32: ...tate 2 Place the right end panel against the right wall of the firebox and secure it with the anchor 3 Install the left end panel in the same manner 4 The rear panel is supplied in three sections which overlap each other The two outer sections are identical and overlap the center section e Identify the right side outer section From the middle of the firebox insert the section upwards behind the to...

Страница 33: ...ections are beveled and the smooth black fire side is notched at the front and straight at the back When installed the top panel rests on the front and back railings j Insert one section of the top panel smooth black surface down Push the section on the left side as far as it will go there is a stop tab at the left end of the railings k Insert the second section in the same manner Push it against ...

Страница 34: ...n Fuel Beds Left Right Driftwood Log Kit 1800DWKV2 Materials Required 1800DWKV2 Driftwood Log Kit which contains 8 Driftwood logs 10 pebbles of assorted colors 1 bag of beige vermiculite Left and right hand platforms ...

Страница 35: ...e rear corner of the burner A cutout under the log helps place it 3 Place log L16 on top of L15 across the burner to the front of the media platform as shown L15 L15 L16 4 Place log L17 on top of the pilot shield across the burner to the front of the media platform as shown 5 Place the pin on log L18 into the hole on the rear media platform Place L18 over the burner to the front of the media platf...

Страница 36: ... L20 L18 7 Place log L22 on the rear corner of the burner A cutout under the log helps place it 8 Place log L21 on top of L22 resting on the front of the media platform L22 L22 L21 Finished AssemblyL22 L22 L21 L20 L19 L18 L17 L16 L15 WARNING Choking Hazard Ensure that the fireplace area is clear of vermiculite particles as these could be ingested by small children Vacuum area after installation IM...

Страница 37: ...are oriented toward the middle and the bags at the bottom The tabs fit into the slots of the burner supports 2 Install the sheet metal cross runners at each end of the assembly linking the front and rear runners by inserting the cross runners tabs into the slots of the runners 3 Place the glass pieces as shown smooth side up on the runners All around the runners vertical tabs keep the glass pieces...

Страница 38: ...es as these could be ingested by small children Vacuum area after installation Installation Fuel Beds 4 Carefully place by hand the fireglass on the surface of the burner patting it gently to form a single layer to the approximate level of the top edge of the flange around the burner Do not pour from the bag or put too much to avoid blocking the burner ports 5 Some fireglass may be added on the pl...

Страница 39: ...d in kit ac cording to gas used See page 30 for instructions 2 Place left and right sides platform around the burner as shown note pilot light cutout The platform rests in place and is not screwed down The openings go underside Installation Logs The following instructions show the best positions for the logs and other pieces to obtain the best fire 1 Place log 12 with the right angle cutout under ...

Страница 40: ...nserted as shown 6 Place log 14 on top of 5 onto the front platform 2 12 3 2 12 3 13 3 12 2 13 5 12 2 5 13 14 7 Place log 17 across the burner with the pin in the hole in the front platform 8 Place log 7 on top of 17 and onto the front platform 9 Place log 9 across the burner with the pin in the hole as shown 10 Place log 15 on top of 9 onto the rear platform 14 13 5 17 13 14 5 17 7 7 17 9 7 17 9 ...

Страница 41: ...ust can block burner ports 14 Place splinters in the embers 9 15 16 15 9 16 11 Finished Assembly 16 11 15 11 17 7 13 14 5 12 2 3 IMPORTANT Approved for use only with the ceramic embers and splinters provided with your Valor fire place The use of any other products may void your fireplace warranty WARNING Choking Hazard Ensure that the fireplace area is clear of embers splinters as these could be i...

Страница 42: ...h log is stamped with its number only on the bottom to identify it Installation The following instructions show the best positions for the logs and other pieces to obtain the best fire Note that logs that are placed across the burner are above the burner and do not touch it 1 Place left and right sides platform around the burner as shown note pilot light cutout The platform rests in place and is n...

Страница 43: ...y 4 Place log L5 with the pin in the hole behind the burner as shown and the left end just behind the pilot shield L2 L2 L1 L5 L2 5 Place log L4 from the top of L5 across the burner to the front of the media tray 6 Place log L3 on top of L4 and rest it on the front of the media tray 7 Place log L8 with the pin in the hole behind the burner as shown L4 L5 L5 L4 L3 L8 L5 ...

Страница 44: ...y 13 Place log L12 on the front of the media tray as shown L9 L11 L9 L11 L10 L11 L10 L12 8 Place log L7 on top of L8 across the burner and resting on the front of the media tray 9 Place log L6 on top of L7 and rest it on the front of the media tray 10 Place log L9 on the rear media tray as shown The log can rest just over the edge of the burner L8 L7 L8 L7 L6 L8 L9 ...

Страница 45: ... preferred Installation Fuel Beds IMPORTANT Approved for use only with the ceramic embers and splinters provided with your Valor fire place The use of any other products may void your fireplace warranty WARNING Choking Hazard Ensure that the fireplace area is clear of embers splinters as these could be ingested by small children Vacuum area after installation L10 L11 L12 L9 L7 L6 L8 L5 L4 L3 L2 L1...

Страница 46: ...om the front lower corner of the window re install it by sliding it between the glass and the frame as indicated WARNING The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the appliance may result To ensure a safe operation Double check that the bottom of the window frame is correctly installed in the bottom support railing Ver...

Страница 47: ...d 3 Connect switch to auxillary 5 pin junction and power connection to jack 4 Run harness assembly to mounted position of junc tion box securing harness to framing using insu lated staples not included 5 Feed harness assembly through a restrain on rear of junction box feeding through until harness sheath is pinched by retainer and providing suf ficent length to make connection to rear of switch an...

Страница 48: ... the snap connection load 4 AA alkaline bat teries into holder included with fireplace then feed back into junction box assembly Note Do not put batteries in the receiver only in the battery holder by the wall switch 14 Test the operation of the wall switch see Appen dix C Wall Switch Operation on page 66 Snap connector Cable tie Side slot Rear view Front view Caution DO NOT USE a screwdriver or o...

Страница 49: ...ing the pairing sequence The handset will count up from 1 to 8 and you will hear two short beeps confirming the pairing is done If you hear one long beep the pairing sequence has failed or the wiring is incorrect This is a one time pairing only and is not required when changing the batteries of the handset or battery holder The remote control system is now ready to use Radio Frequency 918 0 MHz fo...

Страница 50: ...are provided with the kit Cover the screws with the included caps to finish the mounting Once mounted the holder is magnetic simply place the remote gently into the holder IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between 3 and 15 feet away from the appliance but...

Страница 51: ...l bed used altitude and other considerations the flame picture may be improved by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the fuel bed panels and window installed and evaluating the flame picture after a 15 minute warm up Increasing aeration will cause the flames to appear more transparent and blue showing more ceramic effects glow De...

Страница 52: ...tomer s further reference Installation Trim Barrier Screen WARNING HeatShift System MUST be installed on this appliance when using 1830CIK Clean Installation Kit 1830CIK Clean Installation Kit If you are installing the 1830CIK Clean Installation Kit you need to do it BEFORE the cement board 1 Break off tabs from each corner of the fireplace s front opening 9 tabs 2 at each corner and 1 more at the ...

Страница 53: ...optional POWER V Module optional 120V Low voltage Fan optional FAN AC Power MAN Knob Combination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button RBWSK Connector Battery Holder Battery Power Thermocouple 8 Wire Cable bundled Required for optional fan or wifi kits V module required ...

Страница 54: ...le Pipe Length and Pipe Extensions 4 x 6 5 8 Galvanized or Black 46DVA 08A 46DVA 08AB 3 to 7 4DT ADJ 4D7A or 4D7AB 3 to 5 94610608 4 to 8 1 2 4DT ADJ B Galvanized or Black 46DVA 16A 46DVA 16AB 3 to 14 1 2 TC 4DLS1 SV4LA 4D12A or 4D12AB 3 to 10 94610616 4 to 16 TC 4DLS1B SV4LBA Galvanized or Black 46DVA 17TA 46DVA 17TAB 11 to 17 TC 4DLS2 TC 4DLS2B 1 7 8 21 SV4LA12 4D16A or 4D16AB 3 to 14 SV4LBA12 G...

Страница 55: ...012 Roof Flashing 7 12 12 12 46DVA F12 4DT AF12 TF 4FB SV4B 4DF12 6 12 12 12 949606712 Flat Roof Flashing 46DVA FF TF 4F SV4F 949606001 Masonry Flashing TF 4MF New Siding Flashing 658NSFK Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT 949064U Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC 94960608 Decorative Plate 46DVA DC 4DT CS TM 4TR TM 4TP SV4PF 4DFPB 94940612 Cath...

Страница 56: ...ext adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each c...

Страница 57: ... side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved ...

Страница 58: ...WRQ RQ KDQGVHW DLW YH PLQXWHV WR FOHDU RXW DQ JDV WKHQ VPHOO IRU JDV LQFOXGLQJ QHDU WKH ÀRRU If you VPHOO JDV 6723 ROORZ LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO gas go to the next step 3 AUTOMATIC IGNITION 0 1 NQRE LQ 21 SRVLWLRQ QVXUH ODPH GMXVWPHQW NQRE LV VHW WR ORZHVW VHWWLQJ 3 LJ RFDWH WKH SLORW LJ LQVLGH RI UHER 2Q WKH KDQGVHW SUHVV WKH 3RZHU EXWWRQ D VKRUW DFRXVWLF VLJ...

Страница 59: ...ION Always check the ȴre and pilot visu ally to ensure they are o AM ON OFF PM AM Thermostatic Mode Signal Indicator Child Proof Light Fan if included Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Eco Mode F or C To Turn On Fire One Button lighting default Two Button lighting simultaneously Press and hold for 4 seconds until 8 short beeps and a blinking se...

Страница 60: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ȵashing 2 While the icons are ȵashing press the relevant func tion button and hold for 10 seconds 3 The function icon will ȵash until deactivation is com plete Deactivation is complete when the function icon and two horizontal bars are displayed Note If a deactivated button is pressed there is no function a...

Страница 61: ... only works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light turns o Setting 1 Press and hold until ȵashes 2 To adjust light between 20 100 press or 3 To conȴrm setting either press or wait is displayed Note The light works independently of the pilot ȵame If you ...

Страница 62: ...r WiFi the handset will display APP Manual Mode The on o status of the ȴreplace as well as ȵame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset temperature displays brieȵy followed by the room temperature Setting Desired Temperature 1 Press and hold until is dis played and set temperature ȵashes 2 To adjust set temperature press or 3 To con...

Страница 63: ... 5 To conȴrm press ON ON Off Time Setting PROGRAM 1 1 1 OFF are displayed ALL is displayed brieȵy Hour ȵashes 2 To select hour press or 3 To conȴrm press 1 OFF are displayed ALL displayed brieȵy Minutes ȵash 4 To select minutes press or 5 To conȴrm press Note Either continue to PROGRAM 2 and set ON and OFF times or stop programming at this point and PROGRAM 2 remains deactivated Note PROGRAM 1 and...

Страница 64: ...mum countdown time is 9 hours and 50 minutes CAUTION Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit Low Battery Receiver With low battery power in the battery holder the system shuts o the ȴre completely This will not happen if the power is completely interrupted Seven Day Shut Off The system shuts o...

Страница 65: ... no pilot ȵame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot oriȴce if valve has been converted from LPG to NG or vice versa F07 Low battery symbol Permanent Battery icon ȵashes on handset display Low battery in handset F09 F09 4 sec Fire is not responding No electronic control of ȴre Down arrow button was not pressed during pairing Receiv...

Страница 66: ...o gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can turn the pilot on or off and you can increase or decrease the flame height Note that the thermostat and programming functions are not available with the wall switch Appendix C Wall Switch Operation ...

Страница 67: ...is manual Planning Installation Linear with HeatShift Instructions for use with the following Valor Heater Models 1500 1600 1700 and 1800 J or K Incompatible with earlier models 1500I 1600I and 1700I ɄWARNING DO NOT cover or place objects in front of or on top of air outlet s AVOID locating outlet within 7 feet above ȵoor level as discharge temperatures are hot ɄWARNING When placing discharge clos...

Страница 68: ...n Plates 2 for wall valance discharge ONLY LDK9 30 Plenum 7 3 4 197 mm LDK1 48 x 2 LDK4 38 x 2 LDK3 2 14 x 6 2 14 x 6 grilles included white 4 take off collars included 4 take off collars included 4 take off collars included Kits Contents 15 3 4 400 mm LDK7 2 Duct termination plates 4 take off collars included LDK9 30 x 2 4 5 Ø take off collars included ...

Страница 69: ...um 2 ply Flex Kit 2 x 10 0 lengths may be cut to required length LDK10 30 Finishing Frame to use with LDK9 3 5 8 92 mm 3 5 8 92 mm LDK6 2 10 x 5 aluminum ȵex LDK5 supplied separately 38 frame white LDK2 supplied separately 48 frame white 39 5 8 1007 mm 49 5 8 1261 mm Kits Contents 3 11 16 94 mm LDK10 supplied separately 30 frame white 31 11 16 805 mm ...

Страница 70: ...The termination duct plates are approved for vertical upward discharge ONLY DO NOT install plenum or termination plates in ȵoor or ceiling DO NOT COVER OR PLACE objects in front of or on top of air outlet s AVOID locating outlet within 7 feet of the ȵoor level as discharge air temperatures are hot D O N O T D I S C H A R G E T H R O U G H E X T E R I O R W A L L S Note Vertical venting straight o ...

Страница 71: ...ble or rigid 5 diameter UL 181 Class 1 Air Duct 4 use LDK6 kit or equivalent Min 2 1 2 clearance to ceiling Min 30 Max 12 0 See table for offsets Linear 32 3 8 LX2 33 1 4 Linear 8 1 2 LX2 5 1 4 Linear 14 1 2 LX2 17 Linear 9 3 8 LX2 11 Ceiling Min 1 clearance to combustibles around pipe ...

Страница 72: ...1 Class 1 Air Duct 4 use LDK6 kit or equivalent Min 2 1 2 opening required at ceiling Min 30 Max 12 0 6HH WDEOH IRU R VHWV Min 14 32 3 8 8 1 2 14 1 2 9 3 8 Ceiling Min 1 clearance to combustibles around pipe NOTE Discharge opening must be located in the same room as fireplace when using LDK7 ...

Страница 73: ...12 0 Maximum allowable Horizontal Offset X offset for take off that s furthest away Ceiling LDK 1 LDK 3 or LDK 4 Min bend radius Top of fireplace Min 1 clearance to combustibles around pipes Support horizontal sections of pipe using strapping every 24 DO NOT RUN pipe horizontal Minimum slope 4 12 Min bend radius 14 min 5 5 4 12 Vertical Rise Y Min 30 Max 12 0 Maximum allowable Horizontal Offset X ...

Страница 74: ...ng bracket and 1 1 2 standoff mounting bracket and 1 2 standoff 3 1 2 standoff 3 5 8 7 7 8 11 1 2 Top View Front View Right Side View LDK 4 38 LDK 4 5 dia collars 4 C L 8 14 8 4 4 3 3 5 8 7 7 8 11 1 2 1 2 standoff Front View Top View 2 8 1 2 standoffs 6 knock out each end for optional 1270RBK connection 11 1 2 8 4 1 2 wallboard mounting bracket and 1 1 2 standoff mounting bracket and 1 2 standoff ...

Страница 75: ...mounting bracket and 1 2 standoff 8 11 1 2 1 2 wallboard 1 2 standoffs Front View Right Side View 1 2 standoff LDK 9 30 LDK 9 5 dia collars 4 C L 7 1 16 7 1 16 7 1 16 4 3 8 4 3 8 3 9 1 2 Front View Top View 2 6 9 1 2 6 4 1 2 wallboard mounting bracket and 1 1 2 standoff mounting bracket and 1 2 standoff Right Side View 6 1 2 3 ...

Страница 76: ...mensions 5 dia collars 4 C L 7 4 1 2 9 3 4 9 3 4 4 1 2 19 1 2 2 1 2 13 1 2 16 19 1 2 9 3 4 9 3 4 Stand offs fold down for shipping Warning Label Stand offs Front View Top View Right Side View Perimeter of plates may be trimmed to suit installation ...

Страница 77: ...gs LDK9 Minimum 31 4 Min 1 below ȴQLVKHG FHLOLQJ LDK 1 49 LDK 4 39 LDK 1 LDK 4 LDK 3 LDK 3 15 4 5 LDK 1 13 LDK 4 11 UDPLQJ RQ HGJH Top of plenum VXSSRUW UDPLQJ RQ HGJH Min 1 below ȴQLVKHG FHLOLQJ 8 C L LDK 9 Min 1 below ȴQLVKHG FHLOLQJ UDPLQJ RQ HGJH ...

Страница 78: ...tible cavity dimensions Note Min cavity dimensions may be dictated by LDK plenum when installing across corners Min 1 2 clearance to combustibles at ends See detail LDK 1 49 LDK 4 39 LDK 3 15 LDK 9 31 LDK 1 4 LDK 4 4 LDK 3 8 LDK 9 4 2 x 4 on edge 2 x 4 on edge Framing on edge 5 Framing and Clearances Plenums front view ...

Страница 79: ...es all around pipes Plenum support wood Maintain 1 clearance to pipes Framing on edge 1 1 2 min clearance to combustibles top Ceiling Min 2 1 2 clearance to ceiling 1 2 1 2 min clearance to combustibles rear sides 1 min clearance to combustibles all around pipes 4 LDK9 Framing on edge 1 1 2 min clearance to combustibles top 2 min clearance to combustibles use steel stud for LX1 appliances Ceiling ...

Страница 80: ...around pipes 2 x 4 on edge to support plates as necessary maintain 1 clearance to pipes DOO ȴQLVK UHTXLUHG to form plenum above duct termination plates LDK 7 Duct Termination Plates 2 for horizontal installation ONLY Continuous ceiling UHTXLUHG ZLWKLQ FDYLW Note Staining or streaking may occur on light colored ceilings due WR DQ GXVW HWF LQ DLU ȵRZ Maximizing the opening size will help reduce any ...

Страница 81: ...1 2 19 1 2 16 13 1 2 4 4 Stand off Non combustible zone above plates Perimeter of plates may be trimmed to suit installation Combustible framing allowed below plates 5 dia pipes maintain 1 clearance to combustible materials Front View Top View Right Side View Stand off Stand offs ...

Страница 82: ...ZHU WKDQ SOHQXP SRVLWLRQ ȋ GLD SLSLQJ LDK1 or LDK4 plenum LDK9 cannot be installed with1270RBK See HeatShift System manual in Appendix of fireplace installation manual Universal take off supplied with 1270RBK kit Can mount to either end of plenum Maximum 1 x 1270RBK kit per plenum NOTE DO NOT CONNECT 1270RBK directly to fireplace when using LDK Kit connect to LDK plenum ONLY as this will ensure co...

Страница 83: ... kept behind this line 23 3 4 29 3 4 33 3 4 45 NOTE These Mantel Clearances apply ONLY when HeatShift System is installed Mantel Height from Bottom of Unit COMBUSTIBLE Mantel Clearances Linear appliances when using HeatShift System ONLY NON COMBUSTIBLE Flush Hearth Mantel Projections when using HeatShift System ONLY ɄWARNING RISK OF OVERHEATING AND FIRE Ensure HeatShift installation is complete AN...

Страница 84: ...ase be removed to allow the hot airȵow to convect upwards into ducts installed on the ȴreplace Remove the convection baɞe from the appliance It is held in place by screws located right behind the upper edge of the ȴreplace opening 3 screws baɞe Recycle this panel as it is no longer needed Remove convection baɞe 1500 1700 1800 J or K Appliance front panel shown transparent for clarity Convection ba...

Страница 85: ...F O U R 4 t a k e o f f s M U S T B E C O N N E C T E D T O P L E N U M S Install HeatShift collars 1 Remove the four cover plates on top of the appli ance case 6 screws each 1500 1700 1800 J or K 1500 1700 1800 J or K 1600 J or K 1600 J or K 2 Install the collars on the holes on top of the appli ance s case 6 screws each ...

Страница 86: ...181 Class 1 approved air duct to each of the collars and secure it with gear clamps provided DO NOT SPLICE DUCTS 5 Attach the top of the pipe sections to the plenum securing them with the gear clamps provided An upward slope must be maintained in horizontal sec tions of pipes for proper convection Use straps as necessary to maintain the pipes positions Support horizontal sections every 24 inches 6...

Страница 87: ...ecessary to maintain the pipes posi tions Support horizontal sections every 24 inches 6 Continue with the ȴreplace installation 2 stand offs per plate Description Part no LDK1 48 Quad Hot Air Plenum Kit 48 x 2 quad plenum 4005476 5 take off collars 4 4005478 Top mounting bracket standoffs 4007211 8 slotted drive screws 1 4 7 798601 LDK2 48 Outlet Frame Kit for LDK1 Aux Frame SPL 48 x 2 white 40056...

Страница 88: ...t gaskets 2 4000715 40 Pilot stand 4006907 Description Part No 41 Burner mounting bracket A 4006918 42 Burner mounting bracket C 4007223 43 L3 Air shutter stopper 4008078 44 Injector Burner mount 4007702 45 Gas orifice DMS 30 natural gas 4007000 30 Gas orifice DMS 48 propane gas 4007000 48 46 Air shutter 4007748 47 Brass socket pipe plug 4008003 48 Burner module plate 4007076 49 Gaskets module pla...

Страница 89: ... 149 Splitwood log 16 4006682 150 Splitwood log 17 4006695 151 Coal ember bag 4 4006684 152 Splinters grey bagged 1 4005813 153 Bypass screw 185 4000300 154 Bypass screw 170 4006737 155 Right hand platform 4004955AH 156 Left hand platform 4004956AH Description Part No Reflective Glass Liners 1825RGL 82 Retainer clip hardware for 1825RGL kit only 1725RGL 3 83 Top panel Black 2 4006286 Black 2 40062...

Страница 90: ...71 72 73 74 75 76 77 78 79 70 62 63 69 80 67 66 65 64 1 2 4 3 3 5 5 5 5 6 6 8 9 7 7 10 11 12 12 14 13 15 17 18 19 19 20 21 22 23 24 26 25 27 28 29 30 36 37 38 39 40 41 42 43 44 45 46 47 48 49 49 50 50 51 52 53 54 55 56 57 58 59 60 61 ...

Страница 91: ...8 1800DWKV2 1800SWK 1800DGMV2 1800BLK 1815FBL 1825RGL 1840SSL 93 81 87 82 83 84 85 86 88 89 90 91 92 2 3 5 7 9 11 12 13 14 15 16 17 94 95 96 97 98 99 100 100 100 100 101 101 102 116 117 118 119 129 134 135 136 137 151 152 153 154 155 156 ...

Отзывы: