![Valor V71P3T-M Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/valor/v71p3t-m/v71p3t-m_instruction-manual_4551576036.webp)
EN-34 Valor™ 7000
Series
Non-Check Weighing application:
Field
Weight
(Right
aligned)
Space
Unit
(Right
aligned)
Space Stability
(?)
Space
T/N/G/PT
(Right aligned)
Term.
Length
11
1
5
1
1
1
2
2
Each field is followed by a single delimiting space (ASCII: 32).
Definitions:
Weight
- Up to 11 characters, right justified, - at immediate left of most significant
character (if negative).
Unit
- Up to 5 characters, right justified. If the Unit in the Print Content menu was set to
OFF, the unit will be removed in the weight string and replaced by spaces.
Stability
- “?” character is printed if not stable. If weight is stable a space is printed.
T/N/G/PT - “T” is printed for a tare weight, “N” printed if weight is net weight, ‘G’ or nothing
printed if weight is a gross weight, 'PT' is printed if the tare weight is Pre-set Tare.
Application Status (for Check) – Fixed to 6 characters. Display status like " Under", "Accept"
and "Over" for check weighing.
Terminating Character(s) - terminating character(s) printed depending on FEED menu setting.
7.6 Compliance
Compliance to the following standards is indicated by the corresponding mark on the product.
Mark
Standard
This product conforms to the EMC Directive 2004/108/EC, the Low Voltage
Directive 2006/95/EC and the Non-Automatic Weighing Instrument
Directive 2009/23/EC.
The Declaration of Conformity is available online at
europe.ohaus.com/europe/en/home/support/compliance.aspx.
AS/NZS CISPR 11
CAN/CSA-C22.2 No. 61010-1-12, UL Std. No. 61010-1 (3
rd
edition)
NSF/ANSI 169–2009
NSF/ANSI/3-A 14159-1-2010