background image

INSTALLER’S GUIDE

Page 6

         

Figure 1. Dimensions & clearances

Содержание Regency OXYSAFE 2

Страница 1: ...o be installed and maintained satisfactorily However if further information is required our Valor Technical Helpline will be pleased to help Please telephone 08706 061 065 National call rates apply in the United Kingdom INSTALLER Please leave this guide with the owner Valor Heating F i r e l i t e R e g e n c y OXYSAFE 2 OXYSAFE 2 MODEL 3370 MODEL 3371 GC No 32 032 31 C o n t o u r OXYSAFE 2 MODEL...

Страница 2: ... 16 7 1 Check Control Settings 16 7 2 Flame Supervision Spillage Monitoring System 16 7 3 Check Reference Pressure 17 8 OUTER CASE FITTING 17 9 SPILLAGE CHECK 18 10 FINAL REVIEW 19 11 SERVICING PARTS REPLACEMENT 20 11 1 To Replace Radiant s 20 11 2 To Remove the Outer Case 20 11 3 To Replace the Pilot Unit 20 11 4 To Remove the Piezo Generator 21 11 5 To Remove The Complete Burner Module Pipes and...

Страница 3: ... assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy bending Do not lean forward or sideways whilst handling the fire Always grip with the palm of the hand Do not use the tips of fingers for support Always keep the fire as close to the body as possible This will minimise ...

Страница 4: ...de It is visible when the outer case is removed Gas Natural G20 Inlet Pressure 20mbar Gross Heat Input Max 5 6kW 19 100Btu h Min 1 25kW 4 300Btu h Burner Test Pressure Cold 17 95 0 75mbar 7 2 0 3in w g Gas Connection 8mm pipe Burner Injector Upper Centre Radiant Bray Cat 16 Size 120 Lower Outer Radiants Bray Cat 28 Size 250B Pilot Atmosphere Sensing Device OP9093 Ignition Twin spark Piezo electric...

Страница 5: ...s the current edition of the Building Regulations issued by the Department of the Environment and the Welsh Office In Scotland the current edition of the Building Standards Scotland Regulations issued by the Scottish Executive In Northern Ireland the current edition of the Building regulations Northern Ireland issued by the Department of the Environment for Northern Ireland In the republic of Irel...

Страница 6: ...INSTALLER S GUIDE Page 6 Figure 1 Dimensions clearances ...

Страница 7: ... at either side See figure 1 No side clearance is necessary to non combustible surfaces 4 7 Allow a minimum clearance of 90mm from the top surface of the appliance case to the underside of any shelf whether it is made from combustible or non combustible materials This clearance is necessary to allow the case to be lifted off for servicing and also allows the owner sufficient access to operate the ...

Страница 8: ...nder should be at least 50mm above floor level to discourage the placing of carpets or rugs over it The appliance can be fitted to a purpose made proprietary class O 150 C surround 4 9 2 Wall Mounted The wall opening must be within the following dimensions Width Max 440mm Min 305mm Height Max 610mm Min 350mm Though the total height of the closure plate will accommodate a maximum opening height of ...

Страница 9: ...ove the appliance 2 Any opening visible below the appliance may be closed in 4 9 4 Metal Flue Box The appliance can be installed to a metal flue box conforming to BS715 Section 6 For gas fires to BS5258 Part 5 having a minimum internal depth of 165mm The opening must be within the following dimensions Width Max 440mm Min 380mm Height Max 610mm Min 525mm Though the total height of the closure plate...

Страница 10: ...de atmosphere Where the appliance is connected to an unlined brick chimney it is generally unnecessary for the chimney pot to be replaced or for a terminal to be fitted unless the flue has a diameter smaller than 170mm 4 11 If the fireplace opening is an underfloor draught type it must be sealed to stop any draughts 4 12 The flue spigot and any spigot extension must be capable of passing through t...

Страница 11: ...f a fire surround or marble to reduce the opening This may cause cracking of the surround back or marble 5 P R E I N S T A L L A T I O N P R E P A R A T I O N 5 1 Unpacking This appliance is supplied completely assembled except for 3 radiants which are in a cardboard pack inside the firebox The closure plate Literature pack An olive olive nut for gas line connection Remove all the items carefully ...

Страница 12: ... safe place 5 3 6 Remove the radiant pack 5 3 7 Remove any protective film from all the bright trims 5 3 8 Check ignition spark Before attempting to install it is worth checking that the piezo electric spark ignition system operates satisfactorily To initiate the spark temporarily refit the control knob to the spindle Depress the knob and while keeping it depressed turn to the 1 IGN position A spa...

Страница 13: ...eplace opening using a suitable heat resistant material If necessary cut the closure plate but make sure that it overlaps the fireplace opening sufficiently to allow satisfactory sealing Make sure that the rectangular air relief opening is fully within the fireplace opening 5 4 2 Wall mounting See figure 8 The closure plate must be fitted and sealed to the hearth and fireplace opening using a suit...

Страница 14: ... check described in section 5 2 should have confirmed that the fireplace itself is satisfactory 6 A P P L I A N C E I N S T A L L A T I O N 6 1 Installing To A Hearth 6 1 1 Place the fire centrally on the hearth making sure that the spigot lines up with the spigot hole in the closure plate Gently slide the appliance into place The spigot must enter the closure plate to a depth of at least 25mm 6 1...

Страница 15: ... the radiants ensuring that their rear face rests against the horizontal ribs in the rear panel There will be a small gap between their bottom front edges and the retaining channel at the front of the radiant box 6 5 Flue Restrictor Adjustment See figure 10 The appliance has an integral adjustable flue draught restrictor This is supplied set in the fully open unrestricted position and in most case...

Страница 16: ...air has been purged that the pilot orifice is clear and that the thermocouple connections are sound Replace the pilot unit if necessary see servicing section of this manual 7 1 5 Check all the control settings These are Knob Position Radiants Condition 2 Centre radiant on low Outer radiants off 3 Centre radiant fully on Outer radiants off 4 Centre radiant fully on Outer radiants on low 5 All radia...

Страница 17: ...t maximum output Control position 5 7 3 3 After checking turn off the appliance Remove the pressure gauge and replace the test point sealing screw Relight the appliance Turn to the maximum output position and test around the sealing screw for gas soundness with a suitable leak detection fluid 7 3 4 If all the above checks are satisfactory continue with the installation If not check the control and...

Страница 18: ...the maximum setting for a further ten minutes and then repeat the test If the smoke is still not drawn into the appliance inspect the sealing of the closure plate If the sealing is satisfactory but the appliance is installed with the flue restrictor in the closed position see section 6 5 reopen the restrictor reseal the appliance and retest If smoke is still not drawn into the appliance Disconnect...

Страница 19: ... radiants Advise that the fire may give off a slight odour while new This is quite normal and it will disappear after a short period of use Advise that any cleaning must only be carried out when the fire is off and cold Advise the customer that they should read the Owner s guide before operating the fire and always follow the advice in the section headed Cleaning your fire Advise the user that the...

Страница 20: ...nt edges and the retaining channel at the front of the radiant box 11 1 3 Replace in the reverse order 11 2 To Remove the Outer Case 11 2 1 Remove the control knob by pulling clear of the gas tap spindle 11 2 2 Remove the two case retaining screws located at the front of the case near the bottom corners 11 2 3 Lift the case up and forward to clear the rear top location 11 2 4 Replace in the revers...

Страница 21: ... spindle is correctly turned to agree with the gas tap position before refitting the split pin 11 5 To Remove The Complete Burner Module Pipes and Pilot 11 5 1 Remove the outer case as section 11 2 above 11 5 2 Support the inlet isolating elbow to avoid straining the pipework and disconnect the appliance from the elbow 11 5 3 Disconnect the control spindle adapter from the gas tap by removing the ...

Страница 22: ... 8 Push the plug back into the tap body Line up the slot in the plug with the mark previously made on the tap body 11 6 9 Reassemble in the reverse order making sure that the components are correctly engaged Check the operation of the tap and piezo Make sure that the control knob with spindle is correctly turned to agree with the gas tap position before refitting the split pin 1 2 R E P L A C E M ...

Отзывы: