Installation
Open
Open
Close
Close
NG
Flashback
shield (for
LPG only)
LPG Air Shutter
Slider
Open
Close
LPG
NG Air Shutter
Slider & Cover
Check Operation
Turn the
fi
replace
fl
ame up and down using the
remote control to con
fi
rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 9–13.
Set Aeration
Light the
fi
re and allow the unit to warm up for 10–15
minutes to evaluate the
fl
ame picture. Burners are
equipped with an adjustable shutter to control primary
aeration. See the
fi
gures below. The shutter is
factory-set to an aeration gap which will give optimum
performance for the vast majority of installations.
In a few unusual installations, the
fl
ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the ceramic rocks and window installed.
Increasing aeration
will cause the
fl
ames to appear
more transparent and blue showing more ceramic
effects glow.
Decreasing aeration
will cause the
fl
ames to appear
more yellow or orange showing less ceramic effects glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
Air Shutter
Install Front, Trim and Barrier Screen
Install the front chosen by the customer for the
fi
replace. Install as well the barrier screen which is
provided with the front or trim.
Show the customer how to access the controls when
the front or trim are installed and how to remove them
the front or trim.
Follow the instructions provided with the front or trim
and leave those instructions behind for the customer’s
further reference.
QUALIFIED