Operation Checks

Check ignition, pilot stability, burner flames, and the full range of the thermostat using the rotary switch inside the 

appliance and the remote control. See the 

Lighting Instructions

 on page 30 of this manual for full details.

Aeration adjustment

As described on page 21, the burner aeration is adjustable. For the vast majority of installations, no adjustment will 

be necessary. However, in a very few instances, performance may be improved by adjusting the aeration by sliding 

the shutter. Evaluate the aeration only after the unit has warmed up—approximately 15 minutes.

The shutter setting is very sensitive. Small adjustments can make a substantial difference to the flames. We 

strongly advise that adjustments be made in steps of no more than 1/64” (0.4 mm).

Increasing aeration will cause the flame to appear more transparent and blue making the ceramic fuel effects glow 

more.

Decreasing aeration will cause the flames to appear more yellow or orange making the fuel effects glow less. 

Too little aeration may result in black carbon forming and dropping into the firebox.

Operating Your Fireplace

For your safety, this appliance is fitted with a flame supervision device which will 

shut-off the gas supply if, for any reason, the pilot flame goes out. This device 

incorporates a fixed probe, which senses the heat from the pilot flame. If the probe 

is cool, the device will prevent any gas flow unless the MAN knob is in position MAN 

and the metallic core on the valve is pushed in. See the section 

Lighting Instructions

 

on page 30 of this manual.

Cleaning

It will be necessary to clean the glass periodically. During startup, condensation, which 

is normal, forms on the inside of the glass and causes dust and lint to cling to the glass 

surface. Initially, paint, while curing, may deposit a slight film on the glass. We therefore 

recommend that, during the first few weeks of use, the glass be cleaned two or three times 

with non-abrasive common household cleaners (such as dish soap) and warm water. 

Ammonia based cleaners should NOT be used

.

Subsequently, the glass should be cleaned two or three times a season depending on the 

circumstances. Do not clean the glass while it is hot. Always securely replace the window 

before lighting. 

If broken, the glass pane may only be replaced as a complete window 

unit as supplied by the manufacturer.

To remove the window for cleaning, release its top by pulling forward and rotating outwards 

the two bars at the top corners. Unscrew the two spring-loaded bolts at the bottom of the 

window. Lift the window and set it aside with the bolts to avoid damage. See page 16.
To refit the window, place it centrally against the firebox while resting it on the support at 

the bottom of the firebox. Pull the clamping bars forward and rotate inwards to secure the 

top of the window. Fit the two spring-loaded bolts through the bottom of the window and 

tighten to secure. Pull the top of the window forward and release to check that the window 

opens slightly and returns in the event of a delayed ignition. Similarly, check the bottom of 

the window by pulling it forward and releasing. Then, apply light hand pressure against the 

window frame sides to bed-in the window seal. See page 24.
Dust can be brushed from the ceramic logs and firebox walls after removing the front unit 

and opening the window. Dust can also be removed from the burner using a soft brush 

after removing the ceramic logs. When cleaning, make sure that no particles are brushed 

into the slots of the burner.

Owner’s Information

Performance of LPG 

appliances may be 

affected by the quality 

of commercial gas 

supplied in your area.

Содержание Portrait 530ILN/ILP

Страница 1: ...ion Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified i...

Страница 2: ...uld you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation ma...

Страница 3: ...ns 13 Vertical Termination Installations 15 Appliance Preparation 16 Air Restrictors Installation 19 Gas Supply Installation 20 Aeration Setting Check 21 Ceramic Walls Installation 21 Ceramic Logs Ins...

Страница 4: ...lation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate soli...

Страница 5: ...pment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the require...

Страница 6: ...de wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manuf...

Страница 7: ...cations and should be on site when the engine is installed as the parts to make the engine suitable for zero clearance are supplied with the front trim kits except 549 front Fuel Beds The 530I engine...

Страница 8: ...supply pressure must be between the limits shown in the Ratings table on the previous page The supply connection is 3 8 NPT female The opening for the gas supply line is at the rear left corner of the...

Страница 9: ...prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cle...

Страница 10: ...ard may be required if terminating within 7 0 of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length Terminal guard may be required if t...

Страница 11: ...es 32 33 for allowable components 14 36 cm max combustible wall 530 engine Top Outlet w Vertical Rise Horizontal Termination See Conversion to Top Outlet for Solid Direct Vent Co axial Piping in Appli...

Страница 12: ...rough the outer tube and the appliance collar with 6 screws Make sure the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two 6 thread cutting screws su...

Страница 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Страница 14: ...y systems no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear ada...

Страница 15: ...ter Place the appliance in its proper location Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position Dete...

Страница 16: ...orizontal run as shown on page 14 in this manual Fit the termination kit and flashing if required to the exterior of the chimney Secure the appliance to the floor or wall if necessary 1 Vertical Termi...

Страница 17: ...inner vent collar and seal by unscrewing 8 screws To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar Position the inner collar and seal vertically ins...

Страница 18: ...the adapter to the outer collar with two 6 thread cutting screws supplied 1 1 Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top or...

Страница 19: ...e restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the re...

Страница 20: ...s The supply line should include a manual shut off valve and union to allow the appliance to be disconnected for servicing Pressure test the supply line for leaks The appliance and its individual shut...

Страница 21: ...on in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance Ceramic Walls Installation The 530 engine is provid...

Страница 22: ...base log Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this log on the projection at the front center of the base log ensure that the narrow...

Страница 23: ...ace the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal The center right coal has letter R embossed underneath Pl...

Страница 24: ...the window seal 1 Initial Remote Control Set up The receiver and the handset of the remote control system must be initially synchronized before the first use Insert batteries in the remote control re...

Страница 25: ...dust and lint to cling to the glass surface Initially paint while curing may deposit a slight film on the glass We therefore recommend that during the first few weeks of use the glass be cleaned two o...

Страница 26: ...aflet Please always quote part number and description when requesting spare parts Thermocouple probe must be in flame Correct flame appearance With Logs With Coals Your fireplace remote control helps...

Страница 27: ...ime Setback temperature timer TIMER MODE appliance must be in Standby mode pilot ignited The Timer setting allows you to set two burner ON times and two burner OFF times for every 24 hour period Chang...

Страница 28: ...check the tempera ture every five minutes adjusting the amount of fuel needed to give you a steady even heat The display must remain in TEMP mode on the remote handset 1 Timer It is possible to progr...

Страница 29: ...y needs to be replaced Replace with one 9 V battery alkaline recommended Receiver Three short beeps will sound when the motor turns when the batteries need to be replaced Replace with four 1 5 V batte...

Страница 30: ...step 3 AUTOMATIC IGNITION Fig 1 Locate the pilot Fig 3 inside of firebox at left hand side ON OFF switch 1 in ON position MAN knob 2 in ON position set Flame Adjustment knob 3 to lowest setting On th...

Страница 31: ...a wall switch Circulating Fan Kit 555CFK Having variable speed and temperature control it is designed to boost the natural convection process through the appliance It may be fitted before the fireplac...

Страница 32: ...o axial 46DVA VCE Co linear 3PDVCV HS C33U 99 559CLT HS C33F 1313 Snorkel 14 Rise 46DVA SNK14 4DT ST14 Snorkel 36 Rise 46DVA SNK36 4DT ST36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150...

Страница 33: ...8 SV4L48 Black 46DVA 48B 4DT 48 B SV4LB48 Flashings Roof Flashing 46DVA F6 4DT AF6 SV4FA Roof Flashing 46DVA F12 4DT AF12 SV4B Flat Roof Flashing 46DVA FF SV4F Various Venting System Parts Wall Thimbl...

Страница 34: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log br...

Страница 35: ...tor plate 1 logs 320B396 45 Remote receiver 4001911 17 Restrictor plate 2 logs 320B397 46 Hand held control 4001910 18 Restrictor plate 3 logs 320B405 47 Wall mount plate 9000008 19 Window unit 050A21...

Страница 36: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 37a 37b 38 39 40 41 42 43 44 43a 45 46 47 48 42a 41a 41b NG LPG 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Repla...

Отзывы: