background image

Warranty

1. Extended Warranty Coverage

For a period of up to ten (10) years, Miles Industries Ltd., (the “Company”) or its appointed distributor will at its option pay the 

initial purchaser for the repair of, or will exchange the following parts or components which are found to be defective in material or 

workmanship under normal conditions of use and service:

2. Two-Year Parts Warranty 

In addition, for two (2) years from the date of purchase, the Company, at its option, can repair or exchange all parts and components 

not listed above but that are found to have a 

bona fide

 defect in material or workmanship under normal conditions of use.

3. Conditions and Limitations

The warranty registration card must be completed by the initial owner and returned to the Company within 90 days of purchase.

Installation and maintenance must be performed by an authorized and trained dealer in accordance with the Company’s installation 

instructions.

This warranty is void where installation of the unit does not conform to all applicable codes including national and local gas 

appliance installation codes and building and fire codes.

The owner must comply with all operating instructions.

The Company is not responsible for the labor costs to remove defective parts or re-install repaired or replacement parts.

The first purchaser or user of the unit will be responsible for any shipping charges for replacement parts as well as travel time 

incurred by the dealer to perform the warranty work.

This warranty applies to non-commercial use and service and is void if it is apparent that there is abuse, misuse, alteration, 

improper installation, accident or lack of maintenance to the unit.

This warranty does not cover damage to the unit through:

i) 

Improper installation, operational or environmental conditions.

ii)  Inadequate ventilation in the area or competition for air from other household equipment or appliances.

iii)  Damage due to chemicals, dampness, condensation, or sulphur in the fuel supply lines which exceeds industry standards.

This warranty does not cover glass, log breakage or damage to the unit while in transit.

The Company does not allow anyone to extend, alter or modify this warranty and assumes no responsibility for direct, indirect or 

consequential damages caused by the unit. State or provincial laws where the first purchaser or user resides may provide specific 

rights to extend this warranty and, if so, the Company’s sole obligation under this warranty is to provide labor and/or materials in 

accordance with those laws.

4. Discharge of Liability

After two (2) years from the date of purchase, the Company may, at its option, fully discharge all obligations under this warranty by 

paying to the first purchaser/user the wholesale price of any defective parts.

5. No Other Warranty

All obligations to repair this unit are defined in this warranty. Some states or provinces may specifically mandate additional warranties 

on the part of manufacturers, but in the absence of such specific legislation, there is no other warranty or obligation expressed or 

implied.

a)

b)

c)

d)

e)

f)

g)

h)

i)

j)

Part or Component

Defect Covered

Maximum Warranty Period

Exterior steel casing

Corrosion

10 years

Glass

Loss of structural integrity

10 years

Cast iron parts

Corrosion

10 years

Firebox and heat exchanger

Corrosion (but not discoloration) causing 

loss of structural integrity

10 years

WARR

ANT

Y P

ROG

RAM

WARR

ANT

Y P

ROG

RAM

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

VA

LOR

CO M FO

R

T

If you have a problem with this unit, please contact your dealer or 

supplier immediately. Under no circumstances should you attempt 

to  service  the  unit  in  any  way  by  yourself.  The  warranties  in 

paragraphs 1 and 2 are provided only to the first purchaser/user of 

this unit, are not transferable and are subject to the conditions and 

limitations in paragraphs 3, 4 and 5. Please review the conditions 

and limitations carefully and strictly follow their requirements.

Содержание Portrait 530ICN/ICP

Страница 1: ...ion Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified i...

Страница 2: ...uld you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation ma...

Страница 3: ...ns 13 Vertical Termination Installations 15 Appliance Preparation 16 Air Restrictors Installation 19 Gas Supply Installation 20 Aeration Setting Check 21 Ceramic Walls Installation 21 Ceramic Logs Ins...

Страница 4: ...lation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate soli...

Страница 5: ...pment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the require...

Страница 6: ...de wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manuf...

Страница 7: ...cations and should be on site when the engine is installed as the parts to make the engine suitable for zero clearance are supplied with the front trim kits except 549 front Fuel Beds The 530I engine...

Страница 8: ...supply pressure must be between the limits shown in the Ratings table on the previous page The supply connection is 3 8 NPT female The opening for the gas supply line is at the rear left corner of the...

Страница 9: ...prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cle...

Страница 10: ...ard may be required if terminating within 7 0 of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length Terminal guard may be required if t...

Страница 11: ...es 32 33 for allowable components 14 36 cm max combustible wall 530 engine Top Outlet w Vertical Rise Horizontal Termination See Conversion to Top Outlet for Solid Direct Vent Co axial Piping in Appli...

Страница 12: ...rough the outer tube and the appliance collar with 6 screws Make sure the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two 6 thread cutting screws su...

Страница 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Страница 14: ...y systems no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear ada...

Страница 15: ...ter Place the appliance in its proper location Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position Dete...

Страница 16: ...orizontal run as shown on page 14 in this manual Fit the termination kit and flashing if required to the exterior of the chimney Secure the appliance to the floor or wall if necessary 1 Vertical Termi...

Страница 17: ...inner vent collar and seal by unscrewing 8 screws To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar Position the inner collar and seal vertically ins...

Страница 18: ...the adapter to the outer collar with two 6 thread cutting screws supplied 1 1 Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top or...

Страница 19: ...e restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the re...

Страница 20: ...s The supply line should include a manual shut off valve and union to allow the appliance to be disconnected for servicing Pressure test the supply line for leaks The appliance and its individual shut...

Страница 21: ...on in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance Ceramic Walls Installation The 530 engine is provid...

Страница 22: ...base log Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this log on the projection at the front center of the base log ensure that the narrow...

Страница 23: ...ace the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal The center right coal has letter R embossed underneath Pl...

Страница 24: ...the window seal 1 Initial Remote Control Set up The receiver and the handset of the remote control system must be initially synchronized before the first use Insert batteries in the remote control re...

Страница 25: ...dust and lint to cling to the glass surface Initially paint while curing may deposit a slight film on the glass We therefore recommend that during the first few weeks of use the glass be cleaned two o...

Страница 26: ...aflet Please always quote part number and description when requesting spare parts Thermocouple probe must be in flame Correct flame appearance With Logs With Coals Your fireplace remote control helps...

Страница 27: ...ime Setback temperature timer TIMER MODE appliance must be in Standby mode pilot ignited The Timer setting allows you to set two burner ON times and two burner OFF times for every 24 hour period Chang...

Страница 28: ...check the tempera ture every five minutes adjusting the amount of fuel needed to give you a steady even heat The display must remain in TEMP mode on the remote handset 1 Timer It is possible to progr...

Страница 29: ...y needs to be replaced Replace with one 9 V battery alkaline recommended Receiver Three short beeps will sound when the motor turns when the batteries need to be replaced Replace with four 1 5 V batte...

Страница 30: ...step 3 AUTOMATIC IGNITION Fig 1 Locate the pilot Fig 3 inside of firebox at left hand side ON OFF switch 1 in ON position MAN knob 2 in ON position set Flame Adjustment knob 3 to lowest setting On th...

Страница 31: ...a wall switch Circulating Fan Kit 555CFK Having variable speed and temperature control it is designed to boost the natural convection process through the appliance It may be fitted before the fireplac...

Страница 32: ...o axial 46DVA VCE Co linear 3PDVCV HS C33U 99 559CLT HS C33F 1313 Snorkel 14 Rise 46DVA SNK14 4DT ST14 Snorkel 36 Rise 46DVA SNK36 4DT ST36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150...

Страница 33: ...8 SV4L48 Black 46DVA 48B 4DT 48 B SV4LB48 Flashings Roof Flashing 46DVA F6 4DT AF6 SV4FA Roof Flashing 46DVA F12 4DT AF12 SV4B Flat Roof Flashing 46DVA FF SV4F Various Venting System Parts Wall Thimbl...

Страница 34: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log br...

Страница 35: ...tor plate 1 logs 320B396 45 Remote receiver 4001911 17 Restrictor plate 2 logs 320B397 46 Hand held control 4001910 18 Restrictor plate 3 logs 320B405 47 Wall mount plate 9000008 19 Window unit 050A21...

Страница 36: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 37a 37b 38 39 40 41 42 43 44 43a 45 46 47 48 42a 41a 41b NG LPG 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Repla...

Отзывы: