28-5/8” (727 mm)
21-1/4” (540 mm)
13”
(330 mm)
9”
(228 mm)
13”
(102 mm)
4”
(102 mm)
Fan box:
3” (76 mm)
3”
(76 mm)
3”
(76 mm)
9-1/2”
(241 mm)
20”
(508 mm)
to
t
op of fir
ebo
x
Gas line
access
Gas line 34“ (864 mm)
of flex protruding from
sheet metal box
Optional
fan
Optional fan
AutoFire slider
assembly
6’ (1.8 m) fan
power cord
outlet
6’ (1.8 m) Fan power cord
Trim
(sold separately)
Valve
access
panel
X
Y
Dimensions
Cavity
Minimum Cavity Dimensions
Check that masonry step does not interfere with install dimensions
or vent pipe.
If mantel is combustible, see the following section for allowable
clearances.
A non-combustible hearth is required.
Minimum width of fi replace opening at front: 28-7/8” (734 mm)
X = 13-1/2” (343 mm) minimum
16-1/2” (420 mm) with fan
Y = 20-1/2” (521 mm)
23