Valor HORIZON 534JN Скачать руководство пользователя страница 12

12

We recommend having your 

fi

 replace serviced before initial use, and at least once per year by a quali

fi

 ed service 

technician. Contact your dealer quoting the model serial number, if possible. It will be helpful if the 

fi

 replace’s 

 serial number can also be quoted. These numbers are on the information card— see page 7. 
A list of replacement parts is included in your 

fi

 replace Installation Manual. When requesting spare parts please 

quote the part number and description to ensure the correct part is ordered.

 Annual Inspection

To ensure the optimal performance and safety of your 

fi

 replace, contact your dealer to have a quali

fi

 ed 

technician review and verify the list below at least once every year.

Safe Operation List: 

to be performed by a quali

fi

 ed technician only.

 

Inspect and operate the pressure relief mecha-

nism to verify relief mechanisms are free from 

obstruction to operate. See 

Cleaning your 

fi

 replace

 on page 13.

 

Clean glass window with a suitable 

fi

 replace 

glass cleaner. Abrasive cleaners must not be 

used. Be careful not to scratch the glass when 

cleaning. See 

Cleaning your 

fi

 replace

 on page 

13.

 

Inspect the operation of the 

fl

 ame safety sys-

tem Pilot or Flame recti

fi

 cation device.

 

Inspect and ensure the lighting of the main 

burner occurs within 4 seconds of the main 

gas valve opening. Visual inspection should 

match that outlined in the appliance instruc-

tion manual. Inspect primary air openings for 

blockage. See 

Checking pilot and burner 

fl

 ames

 

on page 16.

 

Inspect condition of vent and vent terminal for 

sooting or obstruction and correct if present.

 

Vacuum and clean any excess debris in the 

fi

 rebox that is not supposed to be there.

 

Test and measure the 

fl

 ame failure response 

time of the 

fl

 ame safety system. It must de-

energize the safety shut-o

  in less than 

30 seconds.

 

Check all accessible gas-carrying tubes, con-

nections, pipes and other components for 

leaks. See 

Set up Gas Supply

 section of the 

fi

 replace Installation Manual.

Annual service and maintenance

Caution

Label all wires prior to disconnection when 

servicing controls. Wiring errors can cause 

improper and dangerous operation.
Verify proper operation after servicing.

Содержание HORIZON 534JN

Страница 1: ...gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified ins...

Страница 2: ...rohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used INS...

Страница 3: ...______________________ Options ________________________________________ ________________________________________________ ________________________________________________ Please ask your installer for...

Страница 4: ...replace heats Do not place anything on it Some materials or items although safe may dis color shrink warp crack or peel due to the heat produced by the fireplace Avoid placing candles paintings photos...

Страница 5: ...plemental heater to be used while attended The use of an alternate primary heat source is advisable This unit is not for use with solid fuel Maintenance More frequent cleaning might be required due to...

Страница 6: ...carefully supervised when they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barrier is recommended if there are a...

Страница 7: ...r your safety Valor fireplaces are fitted with a flame supervision device which will shut o the gas supply if for any reason the pilot flame goes out This device incorporates a fixed probe which sense...

Страница 8: ...ls behind Window Frame Window Bolts Window Bolts Info Card Battery Holder Receiver Gas Valve Gas ON OFF Switch Parts of your fireplace Here are the major components of your installed fireplace with th...

Страница 9: ...eplace OFF including pilot Press and hold button on remote or ON OFF button on wall switch If the flames are on they go down and you hear the valve motor wind down You hear a clunk and a beep indicati...

Страница 10: ...tting the fireplace in operation Alternately remove all batteries from the battery holder next to receiver as well as from the handset Automatic shut o in certain conditions Your fireplace s remote co...

Страница 11: ...on Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit To replace the batteries 1 Open the bottom access p...

Страница 12: ...cleaner Abrasive cleaners must not be used Be careful not to scratch the glass when cleaning See Cleaning your fireplace on page 13 Inspect the operation of the flame safety sys tem Pilot or Flame re...

Страница 13: ...hot Let the fireplace cool first before cleaning it Remove Window 1 To remove the window turn the top two bolts through 90 degrees to release the window from the firebox 2 Remove the bottom two spring...

Страница 14: ...n glass panes may only be replaced as a complete window unit as supplied by the manufac turer If the barrier screen becomes damaged it must only be replaced with the same model and version barrier fro...

Страница 15: ...tallation is not covered by the Valor warranty Refit and Check Window 1 Place window over the firebox 2 While holding it push in and screw the bottom two bolts to secure them 3 Insert the top two bolt...

Страница 16: ...recommend at least once a year Sooting Check your fireplace and outside terminal for any sooting Minor amounts of soot developing on logs is common but soot that builds up falls o and accumulates ind...

Страница 17: ...critically low not the batteries in your remote control handset but the batteries in the battery holder beside the wall switch See page 11 for instructions on how to replace the batteries Why do I he...

Страница 18: ...vice technician Contact our dealer quoting the model and serial numbers if possible These numbers can be found on the fireplace information card attached to the fireplace see page 7 Why does my pilot...

Страница 19: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Страница 20: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the w...

Страница 21: ...ndset should be within 15bfeet 4 5 meters of the replace Do not leave the handset on the mantel or hearth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW...

Страница 22: ...MAN Manual Mode Manual ame height adjustment TEMP Daytime Temperature Mode When pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjusts to reach D...

Страница 23: ...n each 24 hour cycle Programs P1 and P2 must be set in the following order during a 24 hour cycle P1 P1 P2 and P2 Day Time temperature high program period Night Time temperature low program period Def...

Страница 24: ...extended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months a...

Отзывы: