![Valor Heartbeat Oxysafe 426 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/valor/heartbeat-oxysafe-426/heartbeat-oxysafe-426_owners-manual_3624092006.webp)
6
Ceramic Coal
•
This product uses a fuel effect piece containing Refractory Ceramic
Fibres (RCF), which are man-made vitreous silicate fibres. Excessive
exposure to this material may cause temporary irritation to eyes, skin
and respiratory tract. Consequently, it makes sense to take care when
handling this article to ensure that the release of dust is kept to a
minimum.
•
Although light coatings of soot are usually burnt off during normal
use, the coal may benefit from occasional cleaning.
•
Should any soot accumulation become excessive, the fuel effect piece
should be removed from the fire for cleaning. Cleaning should be
carried out in a well ventilated area or in the open air by gently
brushing with the pieces held away from your face so that you avoid
inhaling the dust. We do not recommend the use of a normal domestic
vacuum cleaner which may blow dust back into the air.
•
The coal can be lifted out of the fire box when the window surround
and glass have been removed as described on page 5.
•
When replacing the coal, make sure that it rests on the ledges at the
sides of the fire box and that its back face is touching the back of the
fire box (see figure 6).
•
Replace the window and surround after cleaning.
-
Make sure that the top of the window frame is fully hooked over
the top edge of the fire box.
-
Make sure that the outside edges of the window surround sides
are inside the outer case.
D
EBRIS IN
F
LUE /
C
HIMNEY
•
In order to achieve high levels of personal safety and performance efficiency it is
essential that the opening at the back (i.e. the flue) of the fire is kept clear of any
form of obstruction.
•
If the chimney has previously been user for solid fuel fires, or is of normal
construction, deposits of mortar and soot can fall and accumulate until the flue
becomes blocked or restricted.
•
The chimney should be checked annually to ensure continued clearance of the
combustion products and that no dangerous build up of debris has occurred.
•
For advice on servicing your Valor fire, call Valor Service on 0121 386 6203
G
ENERAL
S
ERVICING
•
The fire should be serviced regularly to ensure good mechanical operation. This
servicing can be carried out either by a Valor Service engineer or a CORGI
registered installer.
•
If you require your fire to be serviced, please contact
Valor Service
on
0121 386
6203
and quote the following details;
a) -
model name
b) -
model no.
c) -
appliance serial no. (To be found on a label near the bottom of the right side of
the case.)
•
If you wish to replace any of the owner replaceable parts listed below, please
contact
Valor Sales
on
0121 386 6260
for your nearest stockist of these parts.
Description
Part No.
Ceramic coal
558809
Window unit
522209
Knurled screw for window unit
558819
Window surround
558829
Knurled screw for window surround
558839
•
When fitting replacement parts, follow the instructions contained in this guide.
N.B.
It is important that only Valor approved parts are used for maximum safety.
Figure 6 Coal location