Model
1400KN 1400KP
Gas
Natural
Propane
Altitude (Ft.)*
0-4,500 feet*
Input Maximum (Btu/h)
36,000
36,000
Input Minimum (Btu/h)
19,000
15,000
Manifold Pressure (in w.c.)
4.0”
9.5”
Minimum Supply Pressure (in w.c.)
5.0”
11.0
Maximum Supply Pressure (in w.c.)
10.0”
14.0
Main Burner Injector Marking
DMS#32
DMS#49
Pilot Injector Marking
51
30
Min. Rate By-Pass Screw
220
125
4007154-01
©2018, Miles Industries Ltd.
This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Gas orifi ce
1 Set of conversion labels
1 Minimum rate by-pass screw
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Needle nose pliers, to remove by-pass screw
• Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
• Manometer, to set pressure when regulator is integral
with valve
Specifi cations
WARNING
This conversion kit shall be installed by
a qualifi ed service agency in accordance
with the manufacturer’s instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fi re, explosion or pro-
duction of carbon monoxide may result
causing property damage, personal injury
or loss of life. The qualifi ed service agency
is responsible for the proper installation of
this kit. The installation is not proper and
complete until the operation of the con-
verted appliance is checked as specifi ed in
the manufacturer’s instructions supplied
with the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
H6 Series
INSTALLATION INSTRUCTIONS
Gas Conversion Kit for H6
1400KNGK / 1400KPGK
Use with
Valor Model 1400K Heaters ONLY