54
WARNING
The window unit must be correctly
installed, fastened and sealed after
servicing or serious bodily injury and/or
damage to the appliance may result.
To ensure a safe operation:
• Double-check that the bottom of the
window frame is correctly installed in the
bottom support railing;
• Verify that the levers are hooked properly
to the window tabs then;
• Pull out the top of the window and release
it to insure the springs return it;
• Ensure the window is sealed before
operation.
WARNING
Failure to install the window correctly can:
• leak carbon monoxide.
• affect the performance of the fireplace.
• damage components.
• cause overheating resulting in dangerous
conditions.
Damage caused by incorrect window
installation is not covered by the Valor
Warranty.
Hot Glass Warning Plate
Bottom
railing
Window
Frame
Re
fi
t & Check Window
1. Place window in its bottom railing. Make sure to
remove any fuel bed particles in the railing before
installing the window.
2. Push top of window frame against
fi
rebox.
3. While you hold it, pull and hook side levers to win-
dow brackets on each side.
4. Apply
fi
rm hand pressure around window frame to
make sure window is sealed tight against
fi
rebox.
5.
If the Hot Glass Warning plate has been removed
from the front lower corner of the window, re-
install it by sliding it between the glass and the
frame as indicated.
Installation
Window Re-Installation