1
Oct 2019
Synchronize Remote Control
The receiver and the handset of the remote control sys-
tem must be initially synchronized before the
fi
rst use.
1. Insert alkaline batteries in the remote control
battery holder and handset. The battery holder is
located beside the receiver, near the control valve
under the
fi
rebox, left of the
fi
rebox or beside the
wall switch.
2. With a sharp object, press and hold the receiver’s
reset button until you hear one short and one long
beeps. Release the reset button after the second
beep.
Operation Manual
GV60 MAX
GV60 MAX Electronic Ignition Remote Control
For Valor heaters 700, 780, 785, 1000, 1100, 1150 and 1400 installed with or
without a fan (blower)
3. Within the subsequent 20 seconds, press the small
fl
ame button ( ) on the remote handset until you
hear two short beeps con
fi
rming the sychronization
is set. If you hear one long beep, this indicates the
code learning sequence has failed or the wiring is
incorrect.
This is a one time setting only and is not required when
changing the batteries in the remote receiver. The
remote control system is now ready to use.