Valor G3.5 700MN Скачать руководство пользователя страница 29

29

Installation

Window Re-Installation & Checking

Re

fi

 t and Check Window

1.  Place the window in its bottom railing and push 

its top against the 

fi

 rebox. 

Ensure to remove any 

particles in the railing before installing the window.

2.  While you hold it, hook the side levers into the 

window tabs.

3.  Pull out the top of the window and release it to 

ensure the springs return it.

4. Apply 

fi

 rm hand pressure around the window frame 

to ensure the window is sealed tight against the 

fi

 rebox.

5.  If the Hot Glass Warning plate has been removed 

from the front lower corner of the window, reinstall 

it by sliding it between the glass and the frame as 

indicated below.

Window 

frame

Bottom 

railing

Hot Glass Plate

WARNING

The window unit must be correctly 

installed, fastened and sealed after 

servicing or serious bodily injury and/or 

damage to the appliance may result. 
To ensure a safe operation: 
•  Double-check that the bottom of the 

window frame is correctly installed in 

the bottom support railing;

•  Verify that the levers are hooked 

properly to the window tabs then;

•  Pull out the top of the window and 

release it to insure the springs return it;

•  Ensure the window is sealed before 

operation.

WARNING

Failure to install the window correctly can: 

• Leak carbon monoxide.
• Affect the performance of the fireplace.
• Damage components.
• Cause overheating resulting in dangerous 

conditions.

Damage caused by incorrect window 

installation is not covered by the Valor 

Warranty.

Содержание G3.5 700MN

Страница 1: ...not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrica...

Страница 2: ...s reserved Designed and manufactured for Miles Industries Ltd Valor Fireplaces 190 2255 Dollarton Highway North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appli...

Страница 3: ...Overview 11 Venting 12 Overview 12 Preparation 13 Existing Fireplace Preparation 13 Installation 14 Window and Fan 14 Venting 15 Gas Supply 16 Liners 18 Fuel Beds 20 Install Birch Log Kit 700BLK 20 I...

Страница 4: ...installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paint ings photos and other combustibl...

Страница 5: ...as appliance must use a separate vent system Common vent systems are prohibited WARNING Do not operate this appliance with the glass front removed cracked or broken Replacement of the glass front shou...

Страница 6: ...be between the limits shown in the Ratings section The supply connection is 1 2 NPT female and located on the left side of the control valve The gas line entry point is on the the upper left hand side...

Страница 7: ...hed 721EDV Vintage iron 721EDZ Bronze Backing Plates choose one 717BPB 3 sided floating 717BPBF 3 sided flat 719BPB 4 sided floating 36 1 4 W x 26 5 8 H 37 3 8 W x 27 1 4 H 36 1 4 W x 29 1 4 H Require...

Страница 8: ...ght Side View Minimum Cavity Dimensions Check that masonry step does not interfere with install dimensions or vent pipe If mantel is combustible see the following section for allowable clearances A he...

Страница 9: ...0 mm 39 990 mm Minimum distance from side of appliance liner box to combustible wall 4 102 mm Floor Hearth Clearances Combustible shims supports may be used beneath the appliance to level or raise the...

Страница 10: ...s if used 4 Carefully read the Installer s Checklist included with the fireplace for the installation sequence Caution Only qualified licensed or trained personnel should install this appliance Note I...

Страница 11: ...nal Cap Flashing 2 x 3 approved flex chimney liners running full length Existing unaltered functioning solid fuel burning fireplace chimney Existing non combustible hearth Combustible hearth or floors...

Страница 12: ...outside vent terminal from any direction Check local codes for allowable vertical vent termination Venting Table Maximum vertical height 40 ft measured to bottom of termination Minimum vertical height...

Страница 13: ...ace Ash Retaining Curbs Some fireplaces particularly factory built have a raised curb at the front edge to retain ashes Check the dimensions carefully to ensure the 700 engine will fit behind any rais...

Страница 14: ...e the appliance is fitted into the cavity Refer to instructions provided with the 795CFKV2 to install the fan 6 power cord Remove Window The window is held in place by a spring loaded lever on each si...

Страница 15: ...it towards the back of the firebox 3 Fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure liners to collars with hose clamps included and 2 tapp...

Страница 16: ...ment shut o valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isolate the appliance during press...

Страница 17: ...us must be no smaller than the size of a golf ball approx 1 3 4 or 44 mm as indicated Alternate Inlet Connection When the fireplace opening width is too narrow you may use common elbows and fittings n...

Страница 18: ...firebox on the top of each side release the screw of the side brick anchors one per side just enough to allow them to rotate 4 Install the rear panel on the rail behind the burner against the back of...

Страница 19: ...Installation Liners 7 Install the roof panel supporting it with the rear and side panels 8 Tighten the anchor screws on each side 9 Replace the burner cover 2 screws 10 Replace the log support 2 scre...

Страница 20: ...front edge of the rear log support is flush with the cutout in the burner support platform 2 Place log G4 directly on the burner and slide it all the way to the left There is a groove on the underside...

Страница 21: ...es gently against the pilot shield 7 Place log G6 as shown on top of H11 and G4 8 Place log G5 as shown on top of H10 and G6 The bottom of the log rests against a raised knob on H10 G1 G6 G4 H11 G5 H1...

Страница 22: ...ay not need to place all embers H9 H10 H11 IMPORTANT Approved for use only with the ceramic embers provided with your Valor fireplace The use of any other products may void your fireplace warranty WAR...

Страница 23: ...the rear log support is flush with the cutout in the burner support platform G7 G8 G9 G16 H28 G10 H31 G4 H10 H11 G7 G8 G9 G16 H28 G10 H31 G4 H10 H11 2 Place log G4 directly on the burner and slide it...

Страница 24: ...bs Slide it to the right until it presses gently against the pilot shield 7 Place log G10 on top of G4 and H11 8 Place log G16 on top of H10 and into the groove on top of G10 G10 G4 H11 G16 H10 G10 9...

Страница 25: ...ace all embers H10 H11 H31 IMPORTANT Approved for use only with the ceramic embers provided with your Valor fireplace The use of any other products may void your fireplace warranty WARNING Choking Haz...

Страница 26: ...mped on the bottom Some logs have pegs to help you place them on the burner platform or other logs Install the logs as shown below 1 Confirm the front edge of the rear log support is flush with the cu...

Страница 27: ...the platform depression It should rest against the inside of the front edge of the depression 6 Place log H18 on top of G14 and into the platform depression It should rest against the inside of the fr...

Страница 28: ...ace pebbles to taste around the front of the assembly IMPORTANT Approved for use only with the ceramic embers provided with your Valor fireplace The use of any other products may void your fireplace w...

Страница 29: ...the frame as indicated below Window frame Bottom railing Hot Glass Plate WARNING The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage...

Страница 30: ...il you hear one short and one long beep Release the reset button after the second beep 5 Within the subsequent 20 sec onds press the small flame button on the remote handset until you hear two short b...

Страница 31: ...ltitude and other considerations the flame picture may be improved by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the fuel bed liners and w...

Страница 32: ...lation of trim Install Front Trim and Barrier Screen Install the front or trim chosen by the customer for their fireplace Install as well the barrier screen which is provided with the front or trim Sh...

Страница 33: ...with the kit IMPORTANT The location of the remote control handset is important to assure proper temperature regulation To obtain a constant temperature we recommend that the handset should be between...

Страница 34: ...ptor Block black Battery Holder PILOT MAN Knob Combination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button Optional Wall Switch Kit Connector Thermocouple 8 Wire Cable bun...

Страница 35: ...er 46DVA GK 46DVA CLTA TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and ot...

Страница 36: ...RX VPHOO JDV 6TOP Follow LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWep 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER 21 2 VZLWFK LQ 21 SRVLWLRQ 0 1 NQRE L...

Страница 37: ...he replace Do not leave the handset on the mantel or hearth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperatu...

Страница 38: ...pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjust to reach Daytime Set Temperature Light Dimmer Mode Not available on this replace Fan Mode T...

Страница 39: ...Press SET to scroll to TEMP Hold SET button until TEMP ashes To set Night Time Temperature increases temperature decreases temperature Press or wait to complete setting Setting Program Timers You can...

Страница 40: ...extended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months a...

Страница 41: ...Burner 4007354 28 Pilot bracket 4007142 29 Platform stand 4007799 30 Burner mount 2 4007140 31 Platform fixing bracket 4008079 32 Flex pipe assembly with valve 4002475 33 Anti flashback shield 4007629...

Страница 42: ...ass panel 4004704 70 Top liner panel 4003202 71 Side anchor 4004710 72 Side spacer 3 4004711 73 2 5 4 5 hose clamp 2 4000768 Description Part No 54 Driftwood Log Kit 700DWK Driftwood LogG11 4008169 Dr...

Страница 43: ...43 Appendix C Spare Parts 18 1 2 3 3 4 5 6 7 8 9 13 14 15 16 17 20 26 28 19 32 27 30 29 31 33 34 37 36 35 38 39 40 41 43 42 44 45 46 47 48 49 50 51 11 10 12 73 NG Propane...

Страница 44: ...G14 G4 H18 H21 G12 G13 H20 G14 H18 H21 G7 G8 G9 G16 H28 G10 H31 G4 H10 H11 G7 G8 G9 G16 H28 G10 H31 G4 H10 H11 Ceramic Liners Glass Liners Birch Log Kit 700BLK Driftwood Log Kit 700DWK Traditional Log...

Отзывы: