GAS CONSUMPTION
Model 910
Has a maximum natural gas input of 5.50kW (Gross)
Has a maximum natural gas output of 4.02kW
Has a minimum natural gas input of 2.3kW (Gross)
Has a minimum natural gas output of 1.68kW
Model 910 when converted using kit number 0591011
Has a maximum propane gas input of 5.40kW (Gross)
Has a maximum propane gas output of 3.94kW
Has a minimum propane gas input of 3.8kW (Gross)
Has a minimum propane gas output of 2.77kW
OPERATING YOUR STOVE
This stove is supplied with ceramic fuel effect to simulate a real stove. After some
use, these may change colour. This is quite normal.
The Flame Sensing & Flue Blockage Safety System.
For your safety, this appliance is fitted with a flue blockage safety device that will shut
down the appliance in the event of abnormal flue conditions.
This device is NOT a
substitute for an independently mounted Carbon Monoxide detector
.
The device will also automatically shut off the gas supply to the gas stove if the pilot
flame goes out for any reason.
If the device starts to shut off the gas frequently,
get expert advice.
The system incorporates a probe that senses that the heat from the pilot flame is
correct. If this probe is cool, the device will prevent any gas flow unless the control
knob is kept depressed at the PILOT/IGN position.
If the safety system operates and the flames go out
wait at least ten minutes before
attempting to relight
.
Always make sure that the door is securely closed before lighting.
OWNER GUIDE
Page 5
©
Baxi Heating U.K. Limited 2007.
PLEASE NOTE
When operating your stove for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after approximately twelve hours use.