Valor COSYFLAME BR623 Скачать руководство пользователя страница 13

13

SERVICING & PARTS REPLACEMEMT

Always turn off the gas supply before commencing any servicing. (The inlet elbow for this appliance incorporates an isolating

valve).

This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which

are man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and

respiratory tract. Consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to

a minimum. To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing

we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and

after working on the fire. When replacing these articles we recommend that the replaced items are not broken up, but are sealed

within a heavy duty polythene bag, clearly labelled as RCF waste. This is not classified as “hazardous waste” and may be disposed

of at a tipping site licensed for the disposal of industrial waste. Protective clothing is not required when handling these articles,

but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area and always wash your

hands before eating or drinking.

 

Check that the appliance is clean and that soot or debris is not blocking the gaps between the coals causing an imperfect
flame.

 

Check that soot or debris is not impairing the electrode spark or pilot burner.

 

Check that soot or debris is not blocking any of the slots in the main burner.

 

After servicing, make sure that the ceramic walls and coals are replaced correctly as described in the installation instructions.

 

Always test for gas soundness and spillage after servicing the appliance.

TO REPLACE BURNER PLAQUES

 

Remove the 9 loose coals, front base coal, and rear base coal.

 

Remove the plaque clamping strips by detaching 6 screws.

 

Remove the plaques and the combination gasket between and under the plaques. If necessary remove the gauze and the
gasket beneath it.

 

If necessary fit a new gasket below the gauze. Clean and replace the gauze. Fit a new combination gasket below the plaques.
Push the gasket ends inwards to form a dividing gasket between the plaques.

 

Place the new left hand plaque in position. The left side of the plaque must touch the inside edge of the retaining flange at
the left side of the burner well.

 

Place the new right hand plaque in position. Make sure that the centre section of the combination plaque is between the two
plaques. If there is any play between the plaques and the end retaining flanges, push the plaques firmly to the left squeezing
the centre section of the combination gasket between the two plaques. Any gap should be between the right side of the
plaque and the right side-retaining flange.

 

Fit the front and rear plaque clamping strips. Make sure that the plaques are as far to the left as possible. .

 It is important that

the left side plaque is accurately positioned so that it has the correct relationship to the pilot. 

Fully tighten the clamping strips.

 

Refit the ceramic fuel effects and walls as described in this manual.

 

TO REMOVE THE COMPLETE BURNER UNIT

 

Remove the 9 loose coals, front base coal and rear base coal.

 

Support the inlet isolating elbow to avoid straining the pipework and disconnect the appliance from the elbow.

 

Detach the burner unit from the hotbox by removing 1 screw (As shown in figure 5).

 

Replace in the reverse order.

TO REMOVE THE PILOT UNIT

 

Remove the burner unit - See previous section.

 

Disconnect the electrode lead from tab underneath the electrode.

 

Undo the thermocouple nut at the gas tap.

 

Disconnect the pilot pipe from the pilot unit elbow.

 

Remove the first screw

 s

ecuring the dust cage to the

 

pilot unit / burner. Carefully remove the dust cage and place aside.

 

Remove the second screw securing the

 

pilot unit to the burner. Remove the pilot unit and place it aside

 

Refit in the reverse order

Note

1 The pilot unit must be replaced as a whole assembly. Its individual components are not separately replaceable.
2. Once removed, ensure that the dust cage is cleaned before refitting. Make sure that it locates squarely onto the pilot unit without
any gaps between the cage edges and the pilot unit.

Содержание COSYFLAME BR623

Страница 1: ...E L B R 6 2 3 V A L O R S E C R E T M O D E L B R 4 2 7 V A L O R G R A M P I A N M O D E L B R 4 2 7 I n s e t L i v e F u e l E f f e c t G a s F i r e s G C 3 2 0 3 2 1 5 I N S T A L L E R G U I D E Please keep in a safe place for future reference ...

Страница 2: ...lephone 0345 626341 Local call rates apply P l e a s e l e a v e t h i s I n s t a l l e r G u i d e w i t h t h e u s e r C U S T O M E R C A R E As supplied this appliance is for use with natural gas G20 When converted using Valor conversion kit no 591149 this appliance is for use with propane gas G31 These appliances are for use in the United Kingdom GB and the Republic of Ireland IE only ...

Страница 3: ...r Sealing 8 Preliminary Burner Checks 8 Check Reference Pressure 9 Fitting the Ceramics 9 Full Operating Checks 11 Recheck Control Settings 11 Check for Spillage 11 Flame Supervision Spillage Monitoring System 11 Final Review 12 Servicing 13 Burner Plaque Removal 13 Burner Unit Removal 13 Pilot Unit Removal 13 Gas Tap Removal 14 Piezo Generator Removal 14 Greasing Gas Tap 14 Injector Removal 14 Re...

Страница 4: ...ol plate below the right side of the burner tray It is visible when the bottom front cover is removed The installation must be in accordance with these instructions In the United Kingdom the installation must also be in accordance with a All the relevant parts of local regulations b The Building Regulations issued by the Department of the Environment or the Building Standards Scotland Consolidatio...

Страница 5: ...ow ground level See BS 5871 Pt2 TECHNICAL SPECIFICATION Fire surround height 600mm Fire surround height 470mm Appliance depth 115mm Height of opening required 535mm min 575mm max Width of opening required 335mm min 435mm max Gas Natural G20 Propane G31 Inlet Pressure 20mbar 37mbar Input Max Gross 6 0kW 20 500Btu h 6 1kW 20 800Btu h Input Min Gross 2 2kW 7500Btu h 3 6kW 12280Btu h Output Max 3 5kW ...

Страница 6: ... well as the current edition The flue blocks must have a minimum width not less than 63mm and a cross sectional area not less than 13 000mm2 Older editions of BS1289 required a cross sectional area of 13 000mm2 The current revision of the standard requires 16 500mm2 This appliance is suitable in both cases The total depth of the opening measured from the finished front of the fireplace Including p...

Страница 7: ...t for any evidence of mishandling which might affect the performance Each unit is flame tested before it leaves the factory and as a result there may be slight discoloration around the burner ports There may also be slight thermal cracking across the burner surface that is perfectly normal and is not detrimental to performance 8mm 5 16 Bundy or semi rigid tubing must be used to connect the applian...

Страница 8: ...shape the gas supply pipe to suit the chosen direction of entry and the gas inlet fitting position Refit and tighten the burner assembly retaining screws Refit the burner unit to the appliance to the front leg bracket by the screw Connect the supply line to the appliance For side connection passing in front of the surround The supply pipe will have to be close to the inner face of the surround to ...

Страница 9: ...tion of this manual CHECK REFERENCE PRESSURE The appliance is pre set to give the correct heat input at the inlet pressure shown in the Technical Specification section of this manual No adjustment is necessary Check the burner pressure by fitting a pressure gauge at the test point The test point is on the pipe situated below the bottom right corner of the burner unit Check the pressure with the ap...

Страница 10: ...the four valleys of the front coal Place the left side coal so that the customer will be able to see the pilot flame Figures 14 15 Place the three remaining medium size coals behind and approximately midway between each of the coals in the front row Figures 16 17 Place the two remaining small coals alongside the main coals Figures 18 19 Figure 19 Side Coals in Position Figure 18 Positioning Side C...

Страница 11: ...Make this check with the appliance fully installed with the ceramic fuel effects and front surround in position Close all doors and windows in the room containing the appliance Light the appliance and turn the control knob to HIGH Leave the appliance on for five minutes Place the smoke match into the appliance canopy See Fig 20 The installation is satisfactory if the smoke is drawn into the applia...

Страница 12: ...tched off and a specialist should be consulted Advise the customer that the castings front surround firebox and ceramic pieces can be cleaned as described in the user s instructions and that the coal pieces must be replace as described in those instructions Stress that no extra coals must be added over and above those supplied with the appliance and that any replacements must only be the authorise...

Страница 13: ...If necessary remove the gauze and the gasket beneath it If necessary fit a new gasket below the gauze Clean and replace the gauze Fit a new combination gasket below the plaques Push the gasket ends inwards to form a dividing gasket between the plaques Place the new left hand plaque in position The left side of the plaque must touch the inside edge of the retaining flange at the left side of the bu...

Страница 14: ...y Remove the plug rotating slightly while pulling Clean and grease the plug lightly with suitable grease Do not apply excessive grease Particularly make sure that the gas ports in the tap are not restricted by grease Push the plug into the tap body and position the slot in line with the mark previously made on the tap body Reassemble the niting head and spindle complete with collar and spring maki...

Страница 15: ...ne Appliances 571709 B Gas tap spark generator 1 569429 C Spark generator 1 521069 D Control knob 1 545979 E Pilot unit For Natural Gas Appliances 1 540979 Pilot unit For Propane Appliances 566929 F Burner plaque gasket set 1 569439 G Ceramic rear wall 1 560879 H Front coal 1 9770074 I Rear base coal 1 9770075 J Pack of loose coals 1 9780033 K Dust cage 1 567619 ...

Страница 16: ...6341 To report faults or arrange for your fire to be serviced VALOR SERVICE 0121 386 6203 To order spares or for sales information VALOR SALES 0121 386 6260 CALLERS IN THE REPUBLIC OF IRELAND Call 0044 121 373 8111 U S E F U L T E L E P H O N E N U M B E R S To help us quickly help you please try to have the following information available before you contact us ...

Страница 17: ...ards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Valor is a Corgi registered company All our gas fires must be installed by a competent Corgi Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet or floor of combustible material Valor Hea...

Отзывы: