APPLIANCE DIMENSIONS
OPERATING YOUR FIRE
The Oxysafe flame sensing and flue blockage safety system.
For your safety, this appliance is fitted with a flue blockage safety device that will shut
down the appliance in the event of abnormal flue conditions.
This device is NOT a
substitute for an independently mounted Carbon Monoxide detector.
The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.
If this device starts to repeatedly shut off the gas, get expert advice.
Page 36
©
GDC Group Ltd. OCT 2016
OWNER GUIDE
Figure 2. Dimensions and clearances
Model
Dimension ‘A’ (mm)
Dimension ‘B’ (mm)
Dimension ‘C’ (mm)
Brava
609
713
177
PLEASE NOTE
When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.