background image

Ce guide est disponible en français sur demande.

This appliance is a domestic room-

heating appliance. It must not be used 

for any other purposes such as drying 

clothes, etc.

This appliance is suitable for 

installation in a bedroom or bed 

sitting room.

2

The information contained in this manual is believed 

to be correct at the time of printing. Miles Industries 

Ltd. reserves the right to change or modify any 

information or speci

fi

 cations without notice. Miles 

Industries Ltd. grants no warranty, implied or stated, 

for the installation or maintenance of your heater, 

and assumes no responsibility for any consequential 

damage(s).

© Copyright Miles Industries Ltd., 2023. All rights reserved.

Designed and manufactured for Miles Industries Ltd

.

Valor Fireplaces

190–2255 Dollarton Highway 

North Vancouver, BC, Canada  V7H 3B1

T

604.984.3496  F

604.984.0246

valor

fi

 replaces.com

This appliance may be installed in an 

after-market permanently located, 

manufactured (mobile) home where 

not prohibited by local codes. This 

appliance is only for use with the type 

of gas indicated on the rating plate. 

This appliance is not convertible for 

use with other gases, unless a certi

fi

 ed 

kit is used.

INSTALLER: Leave this manual with the 

appliance.
CONSUMER: Retain this manual for 

future reference.

 Massachusetts: 

The piping and 

fi

 nal gas connection must be 

performed by a licensed plumber or gas 

fi

 tter 

in the State of Massachusetts. Also, see Carbon 

Monoxide Detector requirements in this manual, 

page 35.

WARNING

This product can expose you to chemicals 

including Benzene, which is known to the State 

of California to cause cancer and birth defects or 

other reproductive harm. For more information 

go to www.P65Warnings.ca.gov.

Note: Natural gas, in its original state, contains 

Benzene. 

Содержание AutoFire G3

Страница 1: ...ation and service must be performed by a qualified installer service agency or the gas supplier Hot glass will cause burns Do not touch glass until cooled Never allow children to touch glass A barrier...

Страница 2: ...ay North Vancouver BC Canada V7H 3B1 T 604 984 3496 F 604 984 0246 valorfireplaces com This appliance may be installed in an after market permanently located manufactured mobile home where not prohibi...

Страница 3: ...on 14 Existing Fireplace 14 Installation 15 Window and Fan 15 Venting System and Appliance 16 Gas Supply 17 Liner Panels 18 Fuel Beds 20 Birch Log Kit 739VBLK 20 Driftwood Kit 739VDWK 23 Traditional L...

Страница 4: ...reen is installed Some materials or items although safe may discolor shrink warp crack peel and so on because of the heat produced by the fireplace Avoid placing candles paintings photos and other com...

Страница 5: ...designed and approved as a supple mental heater and provides the potential for most energy conservation when used while attended The use of an alternate primary heat source is advisable This unit is...

Страница 6: ...ction Supply Gas Heater engine 739VN is used with natural gas Heater engine 739VP is used with propane gas The supply pressure must be between the limits shown in the Ratings section The supply connec...

Страница 7: ...003360 742 Traditional Cast Front 4003293 743 FenderFire Double Door w doors 744 FenderFire Single Door w door 745 Clearview Front 4003313 765 Contemporary Surrounds 4003426 772 Matte Black Front 4004...

Страница 8: ...7 8 327 mm 12 1 4 312 mm 14 3 4 375 mm Minimum Height Y 20 1 2 521 mm 20 1 2 521 mm 24 610 mm Minimum Width 28 711 mm 28 711 mm 31 788 mm Dimensions and Cavity Fireplace Dimensions Cavity X Y 28 5 8...

Страница 9: ...ess than 6 152 mm may be located within 5 127 mm of the side of the appliance liner box Floor Hearth Clearances Combustible shims supports may be used beneath the appliance to level or raise the appli...

Страница 10: ...erything using the Pack Con tent sheet Also check that you have Fuel bed packed separately Liner panels packed separately Venting accessories Electrical accessories if using a fan kit Any other access...

Страница 11: ...creen required sold separately 739 fireplace Gas insert does not require a hearth Combustible flooring hearths allowed provided level with or lower than base of insert Chimney Terminal Cap Flashing 2...

Страница 12: ...er of pipe Maximum o set angle 45 sweeping bend to allow for obstructions Venting Notes Where possible avoid joining flex pipes If joints are required use a approved connector and seal joints with RTV...

Страница 13: ...10 0 vertical vent run the vent plate supplied on the appliance with restrictor can be used No need to replace it Min 3 0 Max 10 0 720SWK Terminal 3 Liners 3 min Bend Radius 720SWK M Terminal NOTE De...

Страница 14: ...ome fireplaces particularly factory built have a raised curb at the front edge to retain ashes Check the dimensions carefully to ensure the 739 engine will fit behind any raised curb some curbs may be...

Страница 15: ...f used If the 755CFK Circulating Fan Kit blower is to be installed we suggest that you do it now The fan cavity is accessible from the back of the firebox to facilitate its installation If the fan is...

Страница 16: ...m the firebox by sliding it towards the back of the firebox 3 Fit the two liners ensuring that the exhaust liner is connected to the identified EXHAUST vent collar Secure liners to collars with hose c...

Страница 17: ...ng system by closing its equipment shut o valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Failure to either disconnect or isol...

Страница 18: ...inst the firebox side The panel should be parallel to the edge of the burner plate Slide the panel forward Rotate the anchor back down to hold the panel 5 Place the rear panel against the back of the...

Страница 19: ...and then tighten the two screws Generally the fuel bed support as installed above will generate the best flame for any of the log sets However its position can be adjusted in certain circumstances Mo...

Страница 20: ...he burner s front top rail as indicated G4 Log G4 installed G1 G4 G5 H7 G6 G23 G25 2 Place log G1 behind the burner on the fuel bed sup port and slide it forward until it touches the front vertical ta...

Страница 21: ...the log is on top 7 Place the burned end of log G5 on the notch of G6 and rests its other end on the embers Log G5 installed G5 G6 G4 G5 8 Place log H7 resting its light part on G5 and its forked end...

Страница 22: ...d Embers IMPORTANT Approved for use only with the ceramic embers provided with your Valor fireplace The use of any other products may void your fireplace warranty WARNING Choking Hazard Ensure that th...

Страница 23: ...ogs have pegs to help place them Install the logs as shown below 1 Install G4 ember bed onto the burner placing the groove under the log on the burner s front top rail as indicated 2 Place embers by h...

Страница 24: ...ting its other end right of the embers cavity 6 Place G14 burned end in the flatter area on G4 ember bed and the other end on embers ensuring the notch on G14 is at the top 7 Place G15 on the notch of...

Страница 25: ...r products may void your fireplace warranty WARNING Choking Hazard Ensure that the fireplace area is clear of embers as these could be ingested by small children Vacuum area after installation 9 Place...

Страница 26: ...tamped on the bottom Some logs have pegs to help place them 1 Install G4 ember bed onto the burner placing the groove under the log on the burner s front top rail as indicated 2 Place embers by hand i...

Страница 27: ...t of the embers cavity 6 Place G10 s burned end in the flatter area on G4 ember bed and the other end on embers ensuring the notch on G10 is at the top G20 G21 G21 G9 Log G10 installed G4 G10 G10 7 Pl...

Страница 28: ...G16 G10 G21 G4 739VLSK installed Embers IMPORTANT Approved for use only with the ceramic embers provided with your Valor fireplace The use of any other products may void your fireplace warranty WARNI...

Страница 29: ...s been removed from the front lower corner of the window reinstall it by sliding it between the glass and the frame as indicated below WARNING The window unit must be correctly installed fastened and...

Страница 30: ...th installed options 6 Use a heat resistant tie to gather any extra cable between the receiver and the battery holder Pair Remote Control Receiver and Handset The receiver and handset of the remote co...

Страница 31: ...on The need for adjustment should be determined only by operating the appliance with the fuel bed liners and window installed and evaluating the flame picture after a 15 minute warm up Increasing aera...

Страница 32: ...is fireplace comes complete with a wall mounted holder This holder is not required in all installations but is provided as an optional feature for those customers who wish to mount the remote handset...

Страница 33: ...ination Control Valve Main Valve Knob PANEL red yellow Receiver Antenna RESET Button Optional Wall Switch Kit Connector Thermocouple 8 Wire Cable bundled ON OFF Switch WARNING NO ELECTRICAL CONNECTION...

Страница 34: ...CTA 4DCAT33 Aluminum Flexible Liner 3 or 4 diameter NOTE 2 ply liner approved to CAN ULC S635 suitable for venting gas appliances As manufactured by Z Flex Flexmaster and others 2280 Series AF3 35L TM...

Страница 35: ...e directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VEN...

Страница 36: ...I RX VPHOO JDV 6TOP Follow LQ WKH VDIHW LQIRUPDWLRQ DERYH RQ WKLV ODEHO I RX GRQ W VPHOO JDV JR WR WKH QH W VWep 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER 21 2 VZLWFK LQ 21 SRVLWLRQ 0 1 NQR...

Страница 37: ...r hearth SET scrolls through modes and settings OFF returns to set mode turns the burner and WKH SLORW R DUJH DPH EXWWRQ DPHV up sets hours temperature 6PDOO DPH EXWWRQ DPHV GRZQ DQG R VHWV PLQXWHV te...

Страница 38: ...MAN Manual Mode Manual ame height adjustment TEMP Daytime Temperature Mode When pilot is lit room temperature is measured and compared to set temperature Flame height automatically adjusts to reach D...

Страница 39: ...n each 24 hour cycle Programs P1 and P2 must be set in the following order during a 24 hour cycle P1 P1 P2 and P2 Day Time temperature high program period Night Time temperature low program period Def...

Страница 40: ...extended period of time the system automatically extinguishes the pilot This feature helps the consumer realize cost bene ts by automatically eliminating energy consumption during non heating months a...

Страница 41: ...plate rear 4000175 37 Gasket module plate right side 4000174 38 Gasket module plate front 4000173 39 Gasket module plate left side 4000181 Description Part Number 40 Gasket injector pipe 620C016 41 Th...

Страница 42: ...8769 Driftwood log G11 4008169 Driftwood log G14 4008172 Driftwood log G15 4008305 Driftwood log G26 4008953 Driftwood log H20 4007499 Ember bed G4 4008162 Pebbles 3 4008173 Embers large 2 cup bag 400...

Страница 43: ...43 2 1 3 4 7 7 8 9 6 10 11 12 13 5 5 14 15 16 17 18 NG Propane 19 20 21 22 23 24 33 34 35 36 37 38 40 41 42 43 49 44 48 39 63 62 60 61 64 56 57 55 58 54 50 51 52 53 25 32 59 Appendix C Spare Parts...

Страница 44: ...44 69 70 71 739VBLK Birch Logs Kit 739VLSK Traditional Log Kit 739VDWK Driftwood Log Kit Appendix C Spare Parts G1 G4 G5 H7 G6 G23 G25 G4 G26 G11 G24 H20 G15 G14 G21 G20 H28 G16 G10 G9 G4 67 68 66 65...

Отзывы: