Valor 530ICN Скачать руководство пользователя страница 43

43

Replacement Parts

Code

Description

Part no.

1

Side wall support (2)

330A898

2

Rear wall support

320B320

4

Velcro strip

4000022

5

Port cover

4000828AH

6

Inner vent collar

340B174

7

Inner vent collar seal

620B973

8

Top vent collar seal

568399

9

Top vent cover plate

330A902

10

Wall bracket spacer (2)

320B360AZ

11

Outer vent collar seal

568399

12

Outer vent collar

330A888

13

Restrictor plates (2)

4002895

14

Adjustable plates (2)

4002896

Screws (2) (not shown)

100A757

19

Window unit

050A216

20

Spring loaded bolt (2)

000B214

21

Burner unit incl. #22 NG/
LPG

3000025 / 740K185

22a Aeration shutter assy NG

4002345 / 4002346

22b Aeration shutter assy LPG 320B293 / 3000371

23

Pilot unit complete NG/
LPG

4000062 / 4000063

24

Pilot injector NG/LPG

4002511 / 720A195

25

Thermocouple

4000061

26

Hooked olive for pilot

720A196

27

Electrode

720A543

28

Electrode nut

720A200

29

Olive nut for pilot

420K385

30

Pilot shield

4000144

31

Pilot support bracket

330A904

32

Main burner pipe

030A225

33

Olive nut

220K567

34

Olive

420K342

35

Base support bracket (2)

330A894

36

Elbow injector NG/LPG

720A580 / 9730013

38

Pilot pipe

030A226

39

Snap off olive nut

220K913

40

Window support

320B399

41

Switch bracket

4001070

41a Switch with cable

4001036

41b Cable interruptor/receiver

4001035

42

Interruptor block

4001037

43a GV60 Valve NG

4003094

43b GV60 Valve LPG

4003107

Code

Description

Part no.

44

Ignition cable

4001039

44a Ignition cable sleeve

4002244

45

Receiver G6R-R3AM-ZV (CP)

4001911

46

Handset G6R H3T5-ZV (BJ)

4001910

47

Wall mount holder

9000008

48

Wiring harness

4001187

49

Hot glass warning plate

4003093

50

Ceramic coal set

000B245

51

Centre left coal

640K615

52

Base coal

650K237

53

Centre right coal

640K616

54

Front right coal

640K618

55

Front left coal

640K617

56

Ceramic log set

4000162

57

Right middle log

4000372

58

Right side front log

4000470

59

Front log

4000370

60

Base log

4000368

61

Left middle side log 

4000371

62

Rear log

4000369

63

Ceramic reversible walls 
set

4001160

64

Top far left rock

4001867

65

Top left rock

4001868

66

Top right rock

4001869

67

Top far right rock

4001870

68

Left rock

4001877

69

Right rock

4001878

70

Bottom left rock

4001874

71

Bottom center rock

4001875

72

Bottom right rock

4001876

73

Middle left rock

4001871

74

Middle center rock

4001872

75

Middle right rock

4001873

76

Rock base

4001880

77

Left reversible wall

4001162

78

Rear 

 uted wall

4001881

79

Right reversible wall

4001163

80

Rock base support

4001882AH

81

Ceramic platform

4001879

OWNER’S 
INFORMATION

Содержание 530ICN

Страница 1: ...cinity of this or any other appliance Installation and service must be performed by a qualified installer service agency or the gas supplier Ce guide est disponible en fran ais sur demande This applia...

Страница 2: ...F O R T V A LOR CO M F O R T V A LOR CO M F O R T Commonwealth of Massachusetts 15 Speci cations 17 Dimensions Clearance and Framing 18 Horizontal Termination Locations 19 Horizontal Termination Venti...

Страница 3: ...and draperies Clothing or ammable material SHOULD NOT BE PLACED on or near the appliance Clothing or ammable material SHOULD NOT BE PLACED on or near the appliance This unit MUST be used with a vent s...

Страница 4: ...e A physical barrier is strongly recommended if there are young children or at risk individuals in the house Install an approved after market safety gate to keep toddlers young children and other at r...

Страница 5: ...th or oor The hearth or oor in front of the replace may become very hot in front of the replace may become very hot when the replace heats Do not use the hearth when the replace heats Do not use the h...

Страница 6: ...ting If broken the glass pane may only be replaced as a complete window unit as supplied by the manufacturer If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrie...

Страница 7: ...alve using the manual On Off switch see instructions on next page The appliance uses four 1 5 V AA alkaline batteries for its remote control receiver and one 9 V alkaline battery for its handset The b...

Страница 8: ...l override the wall switch Wall Switch optional Remote control handset Valve Switch ON OFF O O How to Turn Your Fireplace OFF including pilot Familiarize yourself with each of these methods before ope...

Страница 9: ...height NOTE Before using the remote control system for the first time the receiver and the handset must be synchronized See the section Remote Control Initial Set up on page 36 of this manual Set scr...

Страница 10: ...s small ame button to set the minute Press OFF or simply wait to return to MAN mode Double click large ame button Flame automatically goes to high re HI will be displayed Manual Mode Manual Flame Heig...

Страница 11: ...programming SETTING THE DAYTIME TEMPERATURE SETTING THE NIGHTTIME SETBACK TEMPERA TURE Default Settings sun 23 C 74 F Default Settings moon OFF Press large ame button to increase Nighttime Setback Te...

Страница 12: ...l to TIMER moon while the time ashes Press large ame button to set the hour Press large ame button to set the hour Press small ame button to set the minutes Press small ame button to set the minutes S...

Страница 13: ...oes not apply when the power supply is interrupted No change in pilot The appliance shuts off completely when it is continually in pilot position without any change for a period of 5 days Timer Progra...

Страница 14: ...r If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 3 AUTOMA7 1 7 21 J RFDWH WKH SLORW J LQVLGH RI UHER DW HIW DQG VLGH 21 2 VZLWF...

Страница 15: ...attery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall c...

Страница 16: ...instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system...

Страница 17: ...anada please consult provincial and or local authorities having jurisdiction NG LPG Altitude Ft 0 4500 Input Max Btu h 20 500 19 000 Input Min Btu h 6 500 12 500 Manifold pressure in w c 3 5 3 9 10 3...

Страница 18: ...the hot when the fireplace heats Do not use the hearth as a seat or shelf Solid wood flooring hearth as a seat or shelf Solid wood flooring in front of the fireplace if allowed may in front of the fir...

Страница 19: ...center line of meter regulator assembly located within 15 feet 4 6 m below the terminal 36 90 I Clearance to service regulator vent outlet 36 90 J Clearance to non mechanical air supply inlet to the b...

Страница 20: ...or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length A Terminal Guard such as 845TG is required where the vent terminal is located within 7 0...

Страница 21: ...here the vent terminal is located within 7 0 of grade or where accessible 14 36 cm max combustible wall Approved side wall termination Approved through wall shield thimble 530 engine Use 845TG vent gu...

Страница 22: ...es not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two no 6 thread cutting screws supplied Through the wall details If the wall has combustible material appropriat...

Страница 23: ...n the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termination 8 2 4...

Страница 24: ...le construction The appliance must not be connected to a chim ney ue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear adapter 2 x 3 liners 18 ma...

Страница 25: ...ace the appliance in its proper location 3 Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position 4 Determ...

Страница 26: ...l run as shown on page 24 in this manual 5 Fit the termination kit and ashing if required to the exterior of the chimney 6 Secure the appliance to the oor or wall if necessary Vertical Termination Ins...

Страница 27: ...collar and seal by unscrewing 8 screws 4 To make sure that the collars are axially aligned t the adapter 817VAK over the outer vent collar 5 Position the inner collar and seal vertically inside the t...

Страница 28: ...to the outer collar with two no 6 thread cutting screws supplied Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top or Back of Heate...

Страница 29: ...table below to nd out which position is optimal for each type of installation To t the restrictors loosen the two center screws of the left and right inlet ports Place the restrictor assembly under t...

Страница 30: ...must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5kPa The appliance must be isolated from the gas supply pip...

Страница 31: ...ine see Ceramic Rocks Installation section in this manual At this point you can install the 567FGP Top Grille if used logs or rock version only The 567FGP Top Grille is sold separately except with the...

Страница 32: ...5 1 2 3 Burner SIDE VIEW Back Brick Burner bracket Rest the base log behind the burner on its bracket flange BASE LOG Firebox supports 1a 5 Locate the left side log on the ceramic pin on the left han...

Страница 33: ...front coal behind the metal lip at the front of the rebox Its left side should rest over the projection on the left front coal 1 2 4 5 3 1a Burner SIDE VIEW Back Brick Burner bracket Rest the base co...

Страница 34: ...arately fit it now See instructions supplied with the grille 3 Place the rear panel on the rear support as indicated Hold in place and go to next step 4 Place the left and then the right panels in the...

Страница 35: ...ocks L and R Those rocks don t have any peg or hole Install those rocks as indicated at the left and right of the rock pile positioning them so that the arrows underneath point to the front of the rep...

Страница 36: ...ween the glass and the frame as indicated Remote Control Initial Set up The receiver and the handset of the remote control sys tem must be initially synchronized before the rst use 1 Insert alkaline b...

Страница 37: ...may be improved by adjusting the aeration The need for adjustment should be determined only by operating the appliance with the ceramic rocks and window installed Increasing aeration will cause the a...

Страница 38: ...holder to the wall nd a convenient location and use the hardware provided with the kit See the diagram on the right for required hardware and con gurations Note that the holder can be installed at the...

Страница 39: ...39 Wiring Diagram Optional Wall Switch Kit 1265WSK Connector Red Yellow GV60 Wiring Diagram QUALIFIED INSTALLER...

Страница 40: ...DSC V Co linear Flex Connector 46DVA ADF Co axial to Co linear Adapter 46DVA GCL TM 4CAA 4DCAB33 556CLA Co linear to Co axial Adapter 46DVA GK TM 4CTA 4DCAT33 Aluminum Flexible Liner 3 diameter NOTE 2...

Страница 41: ...Flashing TF 4MF Various Venting System Parts Wall Thimble 46DVA WT 4DT WT TM 4WT SV4RSM 4DWT Storm Collar 46DVA SC 4DT SC TM SC SV4AC 4DSC Decorative Plate 46DVA DC 4DT CS TM 4TR SV4PF 4DFPB Cathedra...

Страница 42: ...r from other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards i This warranty does not cover gla...

Страница 43: ...pport 320B399 41 Switch bracket 4001070 41a Switch with cable 4001036 41b Cable interruptor receiver 4001035 42 Interruptor block 4001037 43a GV60 Valve NG 4003094 43b GV60 Valve LPG 4003107 Code Desc...

Страница 44: ...1 2 4 5 6 7 8 9 10 11 12 13 14 19 20 21 22a 22b 23 24 25 26 27 28 29 30 31 33 32 34 35 36 38 39 40 41 42 44 43a 43b 45 46 47 48 41a 41b NG LPG 16a 16b 15a 15b Replacement Parts 44a 49 OWNER S INFORMAT...

Страница 45: ...45 51 52 53 54 55 56 57 58 59 60 61 62 63 50 Replacement Parts 64 65 66 67 69 73 71 74 72 75 76 77 78 79 80 81 70 68 For 530IRN P only For 530ILN P and ICN P OWNER S INFORMATION...

Страница 46: ......

Страница 47: ...rovided will be used for customer records only Online Warranty registration at www valorfireplaces com Cut out page ll information and mail to Miles Industries Ltd Fireplace Information Model Number 5...

Страница 48: ...hut Thank you for choosing a Valor Product Postage needed Miles Industries Ltd 190 2255 Dollarton Highway North Vancouver BC V7H 3B1 Canada Fold here Online Warranty registration at www valorfireplace...

Отзывы: